• Title/Summary/Keyword: 화재 조기감지

Search Result 62, Processing Time 0.035 seconds

Methods for Early Fire Detection and Fire Position Determination Inside the Nacelle of Wind Turbine Generator System (풍력발전기 나셀 내부 화재 조기감지 및 화재 위치 판별 방법)

  • Kim, Da Hee;Lim, Jong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.935-943
    • /
    • 2015
  • This paper presents a method for early fire detection and fire position determination inside the nacelle of wind turbine generator system. The rising temperature and obscuration rates inside the nacelle were used as parameters for fire detection, which can minimize the possibility of a fire detection malfunction because these rising rates do not depend on the absolute values of temperature and obscuration. The fire position was determined using the time difference among various sensor positions for fire detection. The performance of the method was tasted using sets of experiments in a nacelle simulator.

A Experimental Study on the Response Characteristics for Fire Detector by Combustibles (가연물에 따른 화재감지기 응답특성에 관한 실험연구)

  • Choi, Moon-Soo;Hong, Sung-Ho;Lee, Sang-Ho;Park, Sang-Tae;Yoo, Song-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.514-517
    • /
    • 2011
  • 화재감지 및 경보시스템의 설계 목표는 화재발생 초기 단계에서 화재징후를 발견, 피난의 개시를 신속하게 통수하는 것이다. 화재감지기는 다양한 건물 및 환경에 설치되기 때문에 주위 온도 및 가연물의 종류 등 환경적 측면을 심층적으로 고려하지 않으면 적절하게 감지하지 못하는 경우가 발생할 수 있다. 즉, 가연물 종류 등을 고려한 설계에 따라 설치된 화재감지기는 화재시 설계치 대로 조기에 화재를 감지하여 화재 예방 및 화재로 인한 피해를 최소화할 수 있는 것이다. 본 논문은 화재시 조기에 화재를 감지기하여 건축물내 인명피난을 목적으로 설치되는 화재감지기의 응답특성을 분석한 연구이다. 화재감지기의 응답특성을 분석하기 위하여 다양한 가연물을 발생시키고 화재감지기 종류별로 설치한 다음 각 화재감지기의 응답특성을 분석하였다. 그 결과 정온식 열감지기는 열방출률이 적은 화재를 조기에 감지하는 것에 적합하지 않은 것으로 나타났다. 광전식 연기감지기는 회색 계통의 목재류 화재성상에서 응답특성이 떨어졌고, 동일한 공간에서 화원의 수평거리와 동작시간이 비례한다고 볼 수 없었다.

  • PDF

A Study on Fire Detecting Technologies in Tunnel Fire and Escape Tunnel (터널내 화재의 조기감지방법 및 피난터널에 관한 연구)

  • Yang, Tae-Seon;Kim, Eun-Chong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.41-46
    • /
    • 2005
  • Establishing special fire flower sensor of automatic fire equipment in tunnel, it is informed perception, croaker suppression realization and danger occurrence item vehicles driver of tunnel entry verge and connection stream tube institution early stage. which must do to cope immediately. In this paper, quick disposal decides to examine about dictionary perception system that is possible method.

A Study on the adaptability of Carbon monoxide Detector (일산화탄소감지기의 적응성에 관한 연구)

  • Seo, Byung-Keun;Yoon, Myong-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.190-194
    • /
    • 2010
  • 화재감지기는 화재시 발생되는 열, 연기, 불꽃, 독성가스등의 다양한 연소생성물을 감시한다. 기술의 발전으로 화재 감지방식과 기능이 다양해지고 있으며, 이에 따라 다양한 방식의 감지기들이 개발되고 있다. 최근 진보된 감지기들은 화재로 발생 이전에서 부터 감지, 비화재보에 대한 방지는 물론 감지기의 상태 오염 감도 등의 다양 정보를 제공함으로써 유사시 신속하고 정확한 대응이 가능하도록 발전되고 있다. 이러한 진보된 감지기는 막대한 피해가 예상되는 장소, 대피하는데 많은 시간이 소요되는 장소에 적용되어 인명 및 재산피해를 절감 시키고 있다. 일산화탄소감지기 또한 진보된 감지기로 화재 초기 가연물이 연소할 때 발생하는 일산화탄소를 감시한다. 일반화재의 경우 화재 초기에 가연물이 서서히 연소시 불완전 연소로 인한 다량의 일산화탄소가 발생되기 때문에 기존 열, 연기, 불꽃감지기에 비해 빠른 반응을 보여 화재를 조기에 감지함으로써 조기 대응으로 인한 피해를 줄일 수 있을 것이다. 본 연구에서는 실물화재시험 자료를 바탕으로 CO감지기의 조기 감시능력을 확인하였다. CO감지기는 화재초기 발생되는 일산화탄소를 감지하므로 대피시간이 많이 필요한 장소(병원 노인요양시설 학교 백화점 등), 침대 폼메트리스 훈소화재 발생장소(호텔침실 기숙사 숙박업소, 병실 등)등에 적응성이 우수할 것으로 분석된다. 최근 설계되는 초고층 건축물 및 주요 시설물 등에서 화재 시뮬레이션과 가상시나리오 유형 분석을 통해 성능위주의 설계가 적용되고 있다. 그만큼 정확하고 신속한 감지가 중요하다 할 수 있다. CO감지기야 말로 그 기대에 가장 부합될 것으로 분석된다.

  • PDF

P형 화재감지시스템과 퍼지논리를 적용한 화재감지시스템의 동작특성 비교분석

  • 홍성호;심두현;김상철
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.173-178
    • /
    • 2003
  • 화재감지시스템은 화재로부터 발생하는 열과 연기 등을 감지하여 화재발생을 조기에 관계자에게 경보하여 주는 시스템이다. 현재 이러한 화재감지시스템은 일정 규모 이상의 건축물에 필수적으로 설치되어 있으며 이 시스템으로 많은 인명과 재산이 보호되고 있다. 그러나 현재 설비되고 있는 화재감지시스템은 화재 시에 발생되는 열, 연기 등에 대하여 감지기회로에서의 미리 지정한 고정값과의 비교를 통하여 정해진 기준을 넘을 경우 화재로 판정한다. 그러나 고정값을 기준으로 신호를 발신하게 되어있는 화재감지기의 동작은 상황에 따라 불확실한 경우가 발생한다.(중략)

  • PDF

Sensing Characteristics of Fire Detectors in Railway Tunnel by Using Numerical Analysis (수치해석을 이용한 화재감지기 철도터널 화재 감지특성 연구)

  • Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7964-7970
    • /
    • 2015
  • In enclosed areas such as railway tunnels, the heat and smoke generated by a fire can pose a tremendous risk to the life of passengers. To prevent or mitigate such scenarios, fire detectors are installed for early fire detection. This numerical study is preformed for establishing the method of detecting performance of fire detectors installed on railway tunnels. Numerical analysis are conducted using the fire dynamics simulator, developed by the NIST. The temperature of the tunnel walls is determined using the assumed exterior structure of the tunnel. In addition, the detection times of detectors installed at different locations in the tunnel are obtained for different sizes of the fire source, and the results are compared and analyzed.

A Comparative Study on Fire Sensing Factors in Ceiling (반자 내 발생하는 화재 감지 인자 비교 연구)

  • Lee, Gyu-Min;Kim, Jun-Sik;Kim, Dong-Gyu;Kim, Chan-Jin;Kim, Jung-Yeol
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.383-384
    • /
    • 2022
  • 본 논문에서는 반자 내 화재 확산을 막기 위해 최적의 화재 감지 인자를 찾는 것을 목적으로 하였다. 국내에서는 반자 내의 화재로 인해, 대형 화재로 발전하는 많은 사례들이 있다. 기존에 반자 내 화재를 방지하기 위한 온도 화재 감지기가 있지만 온도를 통한 화재 감지는 감지 속도가 느리기 때문에 화재를 조기에 감지하기 어렵다. 그래서 기존의 온도를 이용한 감지를 대체할 다른 화재 감지 인자(CO, CO2)를 비교하는 실험과 기존의 반자 내 화재 감지 인자인 온도를 비교하는 실험을 진행하였다. 두 실험을 통해 CO2가 반자 내 화재 발생 시 온도 대비 보다 민감하게 화재를 감지할 수 있는 인자임을 확인하였다.

  • PDF

Survey of video smoke and flame detection System (동영상을 이용한 연기 및 화염 감지 시스템 연구동향 분석)

  • Kang, Seong-Mo;Kim, Yong-Jun;Kim, Jong-Myon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.621-624
    • /
    • 2010
  • 전통사회가 근대화 되면서 정치 경제 사회 문화 등의 전반적인 발전이 이루어졌다. 농촌지역들이 도시화 되면서 새로운 건물들이 지어지고 기존의 건물들이 증축되면서 건물은 점점 높아지고 대형화 되었다. 또한 건물들이 밀집되면서 한 곳에서 발생한 화재가 건물 내에서 번지거나 또는 주변 건물 등에 옮겨 붙어 대형화재로 이어질 수 있는 위험이 증가되고 있다. 대형 화재를 예방 하고 화재사고의 인명 및 재산 피해를 최소화하기 위해서 화재를 조기에 감지하는 화재감지 기술에 대한 필요성이 증가하고 있다. 화재가 발생 될 때 나타나는 화재의 특징들을 살펴보고 이를 통해 화재를 조기에 판단하기 위한 조건을 알아본다. 또한 이러한 조건들에 부합되는 최근의 연기 및 화염 감지 시스템의 연구 동향에 대해 알아본다.

Improvement of Fire Detection in Rack-type Warehouses using FDS (FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구)

  • Choi, Ki-Ok;Park, Moon-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.55-60
    • /
    • 2019
  • The occurrence of fire in rack-type warehouses may either lead to the warehouses getting entirely burned up or collapsing. This can be attrubuted to the high height of rack-type warehouses, in which combustibles are generally vertically stacked. These characteristics make it difficult to detect a fire early; because detectors are installed on the ceiling, these fires cannot be extinguished at an early stage. In this study, the flow of heat and smoke generated by a fire in a rack-type warehouse was analyzed using a fire dynamic simulator. Through this analysis, the optimal installation conditions of fire detectors for the early detection of fire in rack-type warehouses were confirmed. The analysis results confirmed that complex detection of heat and smoke is required for the early detection of fire in rack type warehouses. Furthermore, it was found that fixed temperature detectors are not suitable for these warehouses, resulting in the need to install heat-smoke hybrid detectors at every three rack levels.

A Comparison Study on the Fire Detection Technology for Buildings and Ships (육상용과 선박용 화재감지기술의 비교연구)

  • Hong, Sung-Ho;Choi, Moon-Soo;Lee, Sang-Ho;Park, Sang-Tae;Yoo, Song-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.510-513
    • /
    • 2011
  • 본 논문은 육상에서 사용되는 화재감지기술과 선박에서 사용되는 화재감지기술의 차이점과 육상용과 선박용 화재감지기 성능시험방법을 비교한 연구이다. 화재감지기술은 비화재보나 오동작을 개선하는 방향으로 발전해 왔다. 육상용 화재감지기는 건물에서 통상적으로 발생할 수 있는 비화재보 요인에 의한 비화재보나 오동작을 방지할 수 있어야 하고, 선박용 화재감지기의 경우에는 염분이 높은 환경에서 사용되는 특성상 염분에 의해 화재감지기가 오동작 또는 비화재보를 발생시키지 않는 구조로 설계되어야 한다. 본 연구에서는 건물에 설치되는 육상용 화재감지기의 최신 발전 방향을 소개하고 선박에서 발생할 수 있는 화재를 조기에 감지할 수 있는 화재감지기술을 고찰하였다.

  • PDF