A Study on the Adaptability of the CO Sensor as A Fire Detection Sensor According to the Test Fire Source of UL 268 (UL 268 시험화원에 따른 CO센서의 화재감지센서로서의 적용성에 관한 연구)

  • Lee, Chun-Ha;Sung, Want-Ki;Lee, Jong-Hwa;Kim, Hyeong-Gweon;Jee, Seung-Wook;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.54-63
    • /
    • 2014
  • The purpose of this study is to test the adaptability of the CO sensor as a fire detector by analyzing its sensing characteristics on fire. In order to test the applicability, we designed and made a fire testing ground whose size is similar to that regulated by UL 268, carried out real fire tests suggested by UL 268, and conducted a comparison analysis on the sensing characteristics between the CO sensor and a photoelectric smoke detector by different types of fire source. The experiment result to the sensing characteristics of the CO sensor is about twice to three times faster than that of the photoelectric smoke detector, proceeding with incomplete combustion such as paper and wood fire source in the initial fire. Especially in case of wood smoldering fire, sensing characteristics of the CO sensor is very excellent.

Survey of video smoke and flame detection System (동영상을 이용한 연기 및 화염 감지 시스템 연구동향 분석)

  • Kang, Seong-Mo;Kim, Yong-Jun;Kim, Jong-Myon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.621-624
    • /
    • 2010
  • 전통사회가 근대화 되면서 정치 경제 사회 문화 등의 전반적인 발전이 이루어졌다. 농촌지역들이 도시화 되면서 새로운 건물들이 지어지고 기존의 건물들이 증축되면서 건물은 점점 높아지고 대형화 되었다. 또한 건물들이 밀집되면서 한 곳에서 발생한 화재가 건물 내에서 번지거나 또는 주변 건물 등에 옮겨 붙어 대형화재로 이어질 수 있는 위험이 증가되고 있다. 대형 화재를 예방 하고 화재사고의 인명 및 재산 피해를 최소화하기 위해서 화재를 조기에 감지하는 화재감지 기술에 대한 필요성이 증가하고 있다. 화재가 발생 될 때 나타나는 화재의 특징들을 살펴보고 이를 통해 화재를 조기에 판단하기 위한 조건을 알아본다. 또한 이러한 조건들에 부합되는 최근의 연기 및 화염 감지 시스템의 연구 동향에 대해 알아본다.

A Study on Domestic and Foreign Test Method of Fire Detectors (국내외 화재감지기 시험의 차이점에 관한 연구)

  • Shin, Seung-Chul;Baek, Dong-Hyun;Go, Eun-Ae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.144-145
    • /
    • 2013
  • 국내에서 생산되고 있는 화재감지기는 설치 환경, 위치, 전기적 및 기계적인 요인에 따라 그 성능의 신뢰성이 차이를 나타내고 있다. 본 연구는 국내에서 제조되고 있는 국내 화재감지기 성능 신뢰성 제고를 위한 방안을 제시하고자 열감지기, 연기감지기, 불꽃감지기 등의 성능시험 관한 각 기관별 주요 내용과 차이점을 비교 검토하였다. 이를 위해 국가시험기관의 27종, 방재시험연구원 46종류, 국제 표준화기구 36종류를 대상으로 한바 다양한 환경에서 적응하고 신뢰성 향상에 비중이 많았다. 감지기에서 발생하는 비화재보, 감지지연 및 기타 원인 불명등과 시험기준의 상호관계를 확인하는 연구가 선행되어야 한다.

  • PDF

A Study on the Analysis of the Tube for Detecting Ignition Point (발화점 감지 튜브 특성분석에 관한 연구)

  • Choi, Young-Kwan;Yoon, Byeong-Don;Kim, Eung-Kwon;Shin, Myong-Chul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.341-344
    • /
    • 2010
  • 발화점 감지 튜브 자동소화장치는 화재발생시 일정한 온도가 되면 튜브가 녹아 가스가 방출되면서 소화용기내의 소화약제가 방출되어 화재를 진압하는 장치로써 전력의 공급 없이도 화재의 감지 및 소화가 가능한 자동소화장치이다. 본 논문에서는 감지온도 $100^{\circ}C{\sim}110^{\circ}C$에서 열에 반응하여 가스방출이 가능한 첨단 폴리머 튜크 재질의 발화점감지 튜브를 개발하고자 기존 발화점 감지 튜브의 특성을 분석하였다.

  • PDF

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

Automatic fire detection system using Bayesian Networks (베이지안 네트워크를 이용한 자동 화재 감지 시스템)

  • Cheong, Kwang-Ho;Ko, Byoung-Chul;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.15B no.2
    • /
    • pp.87-94
    • /
    • 2008
  • In this paper, we propose a new vision-based fire detection method for a real-life application. Most previous vision-based methods using color information and temporal variation of pixel produce frequent false alarms because they used a lot of heuristic features. Furthermore there is also computation delay for accurate fire detection. To overcome these problems, we first detected candidated fire regions by using background modeling and color model of fire. Then we made probabilistic models of fire by using a fact that fire pixel values of consecutive frames are changed constantly and applied them to a Bayesian Network. In this paper we used two level Bayesian network, which contains the intermediate nodes and uses four skewnesses for evidence at each node. Skewness of R normalized with intensity and skewnesses of three high frequency components obtained through wavelet transform. The proposed system has been successfully applied to many fire detection tasks in real world environment and distinguishes fire from moving objects having fire color.

분진을 이용한 화재감지기 감도성능변화에 대한 실험연구

  • Hong, Seong-Ho;Choe, Mun-Su;Park, Sang-Tae;Lee, Bok-Yeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.166-166
    • /
    • 2013
  • 본 연구에서는 화재감지기 중 연기감지기로 가장 많이 사용되고 있는 광전식 연기감지기의 신뢰성에 대하여 분진을 이용하여 검증하는 방법과 감도성능변화에 대하여 분석한 연구이다. 여러번 분진을 이용하여 실험을 실시한 결과 분진의 농도가 높아질수록 감도성능이 저하되는 것을 실험적으로 확인하였고, 동작시간에 대한 실측데이터를 제시하였다.

  • PDF

A Fire Detection System Using Fuzzy Logic with Input Variables of Temperature and Smoke Density (열과 연기농도를 입력변수로 갖는 퍼지로직을 이용한 화재감지시스템)

  • Hong Sung-Ho;Kim Doo-Hyun;Kim Sang-Chul
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.42-51
    • /
    • 2004
  • This paper presents a study on the analysis of fire detection system using fuzzy logic with input variables of temperature and smoke density. The input variables for the fuzzy logic algorithm are measured by fire experiment of small scale with temperature detector and smoke detector. The antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire possibility. Also the triangular fuzzy membership function is chosen for input variables and fuzzy rules to simplify computation. In order to calculate fuzzy values of such fuzzy system, a computer program is developed with Matlab based on graphics user interface. The experiment was conducted with paper and ethanol to simulate flaming fire and with plastic and sawdust to model smoldering fire. The results showed that the fire detection system presented here was able to diagnose fire very precisely. With the help of algorithms using fuzzy logic we could distinguish whether fire or not.

Design Of a Video-Base Fire Detection System Using Texture and Color Spatial Distribution Information (질감 및 색채의 공간 분포 정보를 이용한 비디오 기반 화재감지 시스템)

  • Piao, Feng-Ji;Ryu, Ji-Goo;Moon, Kwang-Seok;Kim, Jong-Nam;Ung, Jang-Dae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.331-334
    • /
    • 2010
  • This paper proposes a new design of a video-base fire detection system using texture and color spatial distribution information. The video sequences used are taken in different days with different lighting conditions having different backgrounds. The time complexity of most previous vision-based fire detection techniques are very high due to lengthy programing. To overcome the problems of lengthy codes and time complexity, in this algorithm, at first we normalize the video image frames by size and color information. Then the spatial distribution of the color information is used to extract the candidate regions, later using visual texture of the fire, we detect the fire regions. The experimental results show an real-time fire detection over thousands of image frames, and have higher detection rate when compared to the conventional fire detection techniques.

  • PDF

A Study on the Reliability Test for Smoke Detection Chamber of Smoke Detector (화재감지기 신뢰성 검증방법에 관한 연구)

  • Hong, Sung-Ho;Choi, Moon-Soo;Park, Sang-Tae;Yoo, Song-Hyun;Yoo, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.150-151
    • /
    • 2013
  • 화재감지기는 연기감지기는 이온전류의 변화량을 감지하는 이온화식 연기감지기와 발광부와 수광부로 이루어진 챔버내에 연기에 의한 광량의 변화를 감지하는 광전식 연기감지기로 구분된다. 국내에서는 광전식 연기감지기가 더 많이 사용되고 있는데 이러한 광전식 연기감지기의 챔버내에 이물질이 침입하게 되면 비화재보를 발생시키게 된다. 본 논문은 연기감지기의 연기감지 챔버에 대한 비화재보를 감소시키기 위한 신뢰성 시험에 대하여 논한 연구이다. 본 연구에서는 광전식 연기감지기의 신뢰성을 검증하는 방법으로 UL 268 등에 규정되어 있는 먼지, 즉, 분진에 대한 신뢰성을 검증방법을 제시하였다. 먼지에 대한 신뢰성 검증을 보다 적절하게 하기 위하여 분진챔버로 분진을 반복적으로 폭로됨에 따른 감도성능 변화를 분석하는 방법이 필요할 것으로 사료된다.

  • PDF