• Title/Summary/Keyword: 화재현장

Search Result 612, Processing Time 0.022 seconds

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석)

  • An, Tea-Ki;Shin, Jeong-Ryol;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1701-1708
    • /
    • 2011
  • A typical day in the subway transportation is used by hundreds of thousands are also concerned about the safety of the various workrooms with high underground fire or other less than in the subway users could be damaging even to be raised and there. In 2010, in fact, room air through vents in the fire because smoke and toxic gas accident victims, and train service suspended until such cases are often reported. In response to these incidents in subway stations, even if the latest IT technology, wireless sensor network technology and intelligent video surveillance technology by integrating fire and structural integrity, such as a comprehensive integrated surveillance system to monitor the development of intelligent urban transit system and are under study. In this study, prior to the application of the monitoring system into the field stations, authors carried out the ZigBee-based wireless sensor networks performance analyzation in the Chungmuro station. The test results at a communications room and ventilation room of the station are summarized and analyzed.

  • PDF

A Study of Evacuation Route Guidance System using Location-based Information (위치기반 정보를 활용한 비상대피경로 안내 지원시스템 개발)

  • Kim, Ho-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.18-23
    • /
    • 2017
  • The shipyard quay process struggles to control workers and maintain a secure working environment because of the presence of at least 1,000 people. Therefore, safety accidents such as an explosion or a fire are likely to occur. With the recent increase in safety accidents at shipyards, the requirements for safety and process monitoring have been strengthened. Major shipyards are conducting researchto monitor the process in real time and to detect the work environment for safety. In this paper, we propose a safe and accurate evacuation route based on the information of the dangerous area and the user's location based on a mobile application to reduce the casualty accidents in the presence of many personnel in a concentrated area. To do this, we analyze the trend of the fire escape system on the ground building, compare various algorithms for escape route calculation, select appropriate algorithms for this study, and perform programming. A basic experiment was conducted to confirm the results. The proposed method is expected to be used in large ship construction sites, passenger ships and large public facilities to reduce accidents in the case of a safety accident.

A Study on the Actual Condition of the Obstacles on the Apartment Escape Stairs and the Perception of Residents (아파트 피난계단에 적치된 장애물의 실태와 입주민의 피난계단 관리에 대한 인식에 관한 연구)

  • Lee, Wonjoo;Lee, Chang-Seop;Lee, Kiyoung
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.116-123
    • /
    • 2017
  • The purpose of this paper is to improve the evacuation stability of residents in apartment fire. For this purpose, the actual condition survey about the obstacles was conducted on 3,056 escape stairs in the 183 apartments. In addition, the questionnaire investigation was carried out a survey targeting the residents of apartments about their experience of fire safety education, perception on safety management of escape stairs, and perception on fire safety. As a result of investigation, we confirmed that the obstacles were formed in the 1,916 escape stairs among the 3,056 escape stairs of the 183 apartments (percent of barricades in escape stairs: 62.70%). Furthermore, it showed that fire safety education experience was found to be 83.10% of subject. The perception on safety management of the subjects in the escape step and the perception on fire safety were $3.84{\pm}0.75%$, and $3.49{\pm}0.61$, respectively. In the results, most of the subjects had a fire safety education and knew how to safety management the escape stairs but, the practice of the safety management action was low. Based on the results in the paper, the policy proposal is that the fire safety education is emphasized to change from the perception to action.

Compressive Strength and Chloride Permeability of High Strength Concrete according to the Variety of Mineral Admixtures (광물질혼화재 종류별 고강도콘크리트의 압축강도 및 촉진 염소이온침투 특성)

  • Moon Han-Young;Kim Byoung-Kwon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.407-414
    • /
    • 2004
  • The purpose of this study is to evaluate the ability to resist chloride ions penetration of the concrete structure under marine environment in south-east asia especially. In this study, high strength concrete(HSC) with various combination of ordinary portland cement(OPC), blast-furnace slag(SG) and silica fume(SF) are cured 23 and $35^{\circ}C$ considering the site weather, and are cured in water for 3, 7 or 56 days respectively. And to investigate the fundamental properties and the resistance of chloride penetration of various HSC, setting time, slump flow, compressive strength, void and ASTM C 1202 test were conducted. Test results show that the compressive strength of HSC is similar regardless of SG replacement ratio and total charge passed of chloride is the smallest at 40% replacement of SG. The compressive strength of G4FS HSC is, besides, outstandingly high at early age compare with other HSC, but the compressive strength of G4F HSC, which is vary according to curing temperature and condition, most high at the age after 7 days. Total passed charge of HSC get larger in the order G4FS

Parkinson's Disease among Firefighters : A Focused Review on the Potential Effects of Exposure to Toxic Chemicals at the Fire Scene (리뷰 : 화재현장에서 노출될 수 있는 화학적 유해물질과 파킨슨병 간의 관련성)

  • Ye, Shinhee;Kim, Hyunjoo;Jeong-Choi, Kyunghee;Kim, Jieun E.;Park, Shinwon;Lee, Yumin;Ha, Eun-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.24 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • Previous studies have found that firefighters have a tenfold higher prevalence of Parkinson's disease (PD) compare to the general population. Firefighters are constantly exposed to various occupational hazards including toxic chemicals of fire residue and the toxic chemicals can effects development and progression of PD. Nevertheless, there were no studies about the association between exposure to chemical byproducts of combustion and the development of PD among firefighters. Thus the aim of this study is to look into existing researches regarding the effect of chemical byproducts of combustion on the development of PD. An extensive literature search was conducted to identify harmful chemical components of smoke and fire residue, using the PubMed database during November of 2016. We searched for relevant articles by combining several keywords that contained "Parkinson's disease" and each of the different toxic chemicals, yielding a total of 1401 articles. After applying the selection criteria, 12 articles were chosen. Chemical substances reported to have a harmful effect on PD, in at least one article, were carbon monoxide, toluene, manganese and lead. Carbon monoxide and metal substances including manganese and lead were found to be associated with an increased PD risk in more than two articles. There was a heightened risk of PD in firefighters due to exposure of chemical byproducts of combustion including carbon monoxide, toluene, manganese and lead. However, to the best of our knowledge, to support this result we need more systematic epidemiological studies about these risk factors of PD among firefighters. In addition, further studies for the effects of prolonged exposure to toxic fire residue on the development and progression of PD in firefighters are needed.

Development of Firefighting Performance Test Drills while Wearing Personal Protective Equipment (소방방화복을 착용했을 때의 소방진압 업무 적합도 평가 프로토콜의 개발)

  • Kim, Siyeon;Lee, Joo-Young
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.138-148
    • /
    • 2016
  • A firefighting simulation was developed in order to assess the physical work capacity of firefighters. The simulation consisted of eight common firefighting tasks, including walking with radiant heat for 3 min while wearing full personal protective equipment (PPE). Nine professional firefighters performed the test a total of three times with a 5 min rest interval between each session. The entire series of tests took approximately 30 min to complete ($381{\pm}30s$). Rectal temperatures were found to increase from $37.4{\pm}0.3^{\circ}C$ to $38.5{\pm}0.4^{\circ}C$, while heart rates were found to increase from $92{\pm}18bpm$ to $185{\pm}13bpm$ during testing. Time to completion of the test drills and non-modified physical fitness values showed a significantly negative correlation (r = -0.728, p < 0.05). Firefighters who had longer periods of firefighting service had longer duration time and also recorded higher scores using an integrated scoring system of time to completion (TTC) and physiological strain index (PhSI). The results indicated that the determination of TTC alone can be a misrepresentation of capability, as it neglects to account for accumulated heat strain. The simulated firefighting test provided a useful insight into physical fitness level, but also the comprehensive work capacity of the firefighters when assessed based on TTC and PhSI.

A Study on the Urethane Foam Material Characteristics and Appropriate Soil Covering for Mine Reclamation Emergency Action through Atificial Fire Test (인공 화재 실험을 통한 광해방지 응급조치용 우레탄 폼 재료 특성 및 적정 복토에 관한 연구)

  • Kim, Soo Lo;Park, Jay Hyun;Lee, Jin Soo;Yang, In Jae
    • Economic and Environmental Geology
    • /
    • v.53 no.3
    • /
    • pp.287-296
    • /
    • 2020
  • Mine Reclamation Project is being carried out with the aim of ensuring a sustainable green living and helping to develop eco-friendly mines by analyzing, removing and preventing the harmful factors. Mines developed during the japanese colonial period and mining boom period are still not repaired throughout the country, and from these scattered risks, public safety is worth pursuing as a top priority. The project that is close to public safety in the mine recalmation project is an emergency treatment, and the most widely used method is a filling method similar to the ground subsidence prevention. If dangerous mine cavity or tunnels are located in the mountains, charging with existing materials may not be possible, or unreasonable cases may occur, and new methods of technological development are required. Emergency actions should be carried out safely and efficiently to prevent the loss of precious people's lives on the hiking paths adjacent to dangerous mining sites. In these field conditions, urethane foam materials may be an alternative. In this study, the applicability of urethane foam materials in mining was reviewed through overseas cases. It was also tested on the appropriate depth of top soil for the protection of urethane foam materials through forest fire simulation test. The test result show that approximately 15cm of soil covering (recommended 20cm over) was suitable for maintaining the function of foam materials from forest fires.

Flame Retardant and Weather Proof Characteristic of Dan-Chung Treated Wooden by Flame Retardant Performance (방염처리 방법에 따른 단청목재의 방염 및 내후특성)

  • Park, Cheul-Woo;Hong, Sang-Wan;Lee, Jong-Kyun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.122-130
    • /
    • 2013
  • One of recent methods to protect wooden cultural assets from fire, there is the flame retardation which is applied directly to wood and it is to prevent fire through securing flame resistance for the material and delaying combustion when failed fire in advance and then to gain time for people in the room to evacuate and it has same goal with the Korean Fire Service Act by protecting life and property. However, in case of spraying flame retardant on the colored surface of the wooden cultural assets, there are continuous problems of decoloration, efflorescence and water absorbtion after sometime and accordingly there increases danger of damages of cultural assets. So when treating with flame retardant on wooden cultural assets, there has to be no problems on dancheong after sometime and securing sustainable methods for flmae retardation should be preceded. Accordingly, this study aims to provide basic sources for selecting proper flame retardation methods by evaluating and analyzing flame retardation capabilities according to types of flame retardants which are frequently used nowadays and spraying them on the dancheong-painted surface and confirming if there is no problem on the dancheong and wood after sometime and if flame retardation effect is sustainable with its quality and capability through precise analysis.

Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated (인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.1-6
    • /
    • 2018
  • This study is to analyze the characteristics of the yellow insulation ring type of the CSST used for tubing when it is artificially deteriorated and damaged by burning. The CSST for tubing consists of a tube, protective coating, nut, yellow insulation ring, packing, and socket. In addition, it is thought that a yellow insulation ring and rubber packing were used to connect the tube and socket in order to improve the airtightness and insulation performance. The result of the verification of the data acquired from the tests in the 95% confidence interval shows that the Anderson-Darling (AD) and P value were analyzed to be 0.945 and 0.015, respectively. This confirms that the test data of the CSST for tubing is reliable. The analysis of the arithmetic mean of the insulation resistance of a CSST showed that the CSST damaged by burning by a torch, and the one damaged by electrical burning, was $16.7k{\Omega}$ (the greatest relatively) and $208{\Omega}$ (the lowest), respectively, while it was $1.72k{\Omega}$ in the case of a normal product. Therefore, the analysis result of the insulation resistance of the CSST collected from the scene of a fire can be utilized to examine the cause of damage by burning. In addition, it was found that when the maximum current of 97 A was applied to the CSST for about 5 s using a Primary Current Injection Test System (PCITS) the protective film and insulation ring of the CSST has no difference from that of a normal product. However, a part of the metal tube was melted.

A Study on Application of Test Bed for Verification of Realistic Fire Management Technology (실감형 화재관리기술 검증을 위한 테스트베드 적용방안 연구)

  • Choi, Woo-Chul;Kim, Tae-Hoon;Youn, Joon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.745-753
    • /
    • 2021
  • Recently, a large fire occurred in a multi-use facility used by a large number of citizens, including the vulnerable, resulting in a lot of injuries and damages. Although several pilot studies have been conducted to reduce such incidents, the development of advanced disaster response technology using the latest spatial information and IoT technology is still insufficient. In this study, a pilot test bed is built to demonstrate detailed technologies derived through the first stage of realistic fire management technology research for the development of applied technology in the field. In detail, the building conditions and candidate sites of the test bed were first investigated and analyzed to derive satisfactory conditions and candidate target buildings. A second pilot test bed was then selected, and the necessary sensor and facility infrastructure were built to demonstrate the outcomes. Finally, a scenario was produced for technology verification, and a test bed system was developed. The pilot test bed is expected to contribute to verifying intermediate outcomes of realistic fire management research projects, enhancing the quality of the developed technologies.