• Title/Summary/Keyword: 화재위험

Search Result 1,680, Processing Time 0.025 seconds

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.

방화정보 - 사우나 시설의 화재 예방 대책

  • Hwang, Hyeon-Su
    • 방재와보험
    • /
    • s.60
    • /
    • pp.70-75
    • /
    • 1994
  • 사우나실은 높은 열과 가연성 목재가 내장되어 있어 화재 발생 위험이 높으며 또한, 열원으로 대부분 전기 히터를 사용하기 때문에 물이 묻어있는 상태의 입욕자에게는 감전 사고의 위험도 높다. 이 글은 1988년부터 1990년까지 3년간 영국의 사우나 시설에서 발생한 화재 통계 및 1990년 캐나다의 온타리오(ontario)에서 발생된 2건의 화재 사례를 중심으로 사우나 시설의 화재 예방 대책과 인명 안전 대책에 대하여 기술하였다.

  • PDF

화재안전 및 보험상식 - 다중이용업소 위험관리 및 보험

  • Jang, Tae-Ho
    • 방재와보험
    • /
    • s.142
    • /
    • pp.54-55
    • /
    • 2011
  • 다중이용업소는 화재사고가 빈번하게 일어날 뿐만 아니라 그 피해가 대부분이 사회적 약자에게 발생한다. 아래 표는 2010년 다중이용업소에서 발생한 화재건수를 나타내는 것으로 전기적인 요인과 부주의에 따른 화재가 대부분이다. 다중이용업소의 보험가입 현황은 2009년 기준으로 다중이용업소를 운영하는 소상공인의 50.1%만이 화재보험에 가입되어 있는 실정이다. 이번 호에는 다종이용업소의 위험분석과 이에 대한 보험상식에 대하여 알아보고자 한다.

  • PDF

업계탐방 - 동양화재 위험관리 연구소

  • O, Jeong-Gyu
    • 방재와보험
    • /
    • s.107
    • /
    • pp.59-61
    • /
    • 2005
  • 이번 탐방은 대한민국 최초의 손해보험회사로서 83년의 역사와 전통을 자랑하는 동양화재의 중추 조직으로서 보험계약자를 위한 사고예방활동과 적정요율 산출을 위한 언더라이팅 업무를 수행하고 있는 동양화재 위험관리연구소를 방문하였다.

  • PDF

위험물저장소의 화재방호 비용효과 분석

  • Yun, Jong-Cheol
    • 방재와보험
    • /
    • s.106
    • /
    • pp.27-32
    • /
    • 2005
  • 이 글은 The Hazardous Installation Directorate의 최우수 조사관인 Alan Tyldestey와 Atkins에서 화재안전 컨설턴트로 근무하고 있는 Peter Rew와 Richard Houlding가 위험물저장소의 화재방호 비용효과분석에 관해 발표한 연구보고서를 번역한 것이다.

  • PDF

'92방재세미나 - 위험성 평가 기법

  • Korea Fire Protection Association
    • 방재와보험
    • /
    • s.53
    • /
    • pp.68-77
    • /
    • 1992
  • 한국화재보험협회에는 지난 2월 25일 협회 1층 강당에서 위험성 평가 기법에 대한 위험관리 세미나를 개최했다. 대형 특수건물 소유주 및 화화공장의 관계자, 내무부 및 유관가관, 방재시험연구소의 방재기술 정보회원, 손해 보험회사 임직원 등 3백여 명이 참석한 이번 세미나의 개최 목적은 보험시장 개방과 보험의 국제화에 따라 과학적인 위험관리 기법을 도입해 위험방지와 함께 인수위험을 효율적으로 관리, 보험 회사의 경쟁체제 확립에 기여하기 위한 것이다.

  • PDF

Effects of evacuation delay time and fire growth curve on quantitative risk for railway tunnel fire (철도터널 화재 시 피난개시시간지연 및 화재성장곡선이 정량적 위험도에 미치는 영향)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu;Lee, Hoo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.809-822
    • /
    • 2018
  • A quantitative risk assessment has been introduced to quantitatively evaluate fire risk as a means of performance based fire protection design in the design of railway tunnel disaster prevention facilities. However, there are insufficient studies to examine the effect of various risk factors on the risk. Therefore, in this study, the risk assessment was conducted on the model tunnel in order to examine the effects of the evacuation start time delay and the fire growth curve on the quantitative risk assessment. As a result of the analysis of the scenario, the fatalities occurred mainly when escapes in the same direction as the direction of the fire smoke movement. In addition, after the FED exceeded 0.3, the maximum fatalities occurred within 10 minutes. In the range of relatively low risk, distance between cross passages, evacuation delay time and fire growth curve were found to affect the risk, but they were found to have little effect on the condition that the risk reached the limit. Especially, in this study, it was evaluated that the evacuation delay time reduction, fire intensity and duration reduction effect were not observed when the distance between cross passages was more than 1500 m.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

A Study on Fire Risk & Countermeasure of RDF(Refuse Derived Fuel) (생활폐기물 고형연료제품의 화재위험과 안전대책에 관한 연구)

  • Jeong, Ui-Su;Gang, Gyeong-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.17-25
    • /
    • 2009
  • 세계의 모든 나라가 화석연료를 대체하는 태양광, 풍력 등의 그린에너지 기술개발에 주력하고 있으며, 한편으로는 에너지의 효율제고 및 재생을 위하여 폐기물로부터의 자원순환을 이룩하는 폐기에너지 회수에도 많은 노력을 기울이고 있다. 그 하나의 방편이 버려지는 쓰레기에서 에너지를 회수하는 고형재생연료인 RDF(생활폐기물 고형연료 제품, Refuse Derived Fuel) 생산이다. 우리나라에서는 유일하게 강원도 원주시에서 하루 80톤을 생산하고 있으며 아직은 기술도입 초기단계에 있는 가연성폐기물의 연료화 기술이다. RDF의 특성은 불연성 성분이 제거된 일반 가연물을 분쇄하여 압출성형 가공한 펠릿형상의 고체연료로서의 열적 특성이 우수하나 화재안전 측면에서는 제조 및 취급공정에서의 일반적인 가연물 화재위험성을 가지고 있고, 저장과정에서는 축열발열에 의한 자연발화 위험성이 상존하며, 저장형태, 특히 사이로의 경우 구조특성으로 인하여 화재진압도 쉽지않다. 본 논문에서는 일본의 RDF 화재사례를 중심으로 그 화재 위험 특성과 안전대책을 고찰하고자 한다.

  • PDF