• Title/Summary/Keyword: 화재위험도

Search Result 1,680, Processing Time 0.028 seconds

A Study on the Risk Assessment Using Simulation and Case Study of Urban Fire - Focusing on Market - (도시화재 사례 조사 및 시뮬레이션을 이용한 위험성 평가 - 시장지역을 중심으로 -)

  • Shin, Yi-Chul;Koo, In-Hyuk;Hayashi, Yoshihiko;Ohmiya, Yoshifumi;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.1-7
    • /
    • 2011
  • As population grows and urban facilities are concentrated in specific areas due to recent urbanization and industrialization, cities have structures vulnerable to both natural and man-made disasters. Most of these structures, whether buildings or residential houses, are left in a defenseless state if not given the appropriate check-up before they are built. The process of rapid urbanization without establishing the proper urban fire risk assessment will surely lead to disasters. This phenomenon occurred during the process of rapid urbanization and maybe said the result of chaotic urban expansion where modern urban infrastructure is not yet equipped in the city. Under the said circumstances, propagation processes of Korean urban fire cases were investigated to establish fire risk assessment system. Moreover, this paper explains the experiment performed for establishing urban risk assessment model. The said experiment was conducted using the new urban fire risk assessment model.

Fire Risk Index and Grade Evaluation of Combustible Materials by the New Chung's Equation-XII (새로운 Chung's equation-XII에 의한 연소성 물질의 화재위험성지수 및 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.388-396
    • /
    • 2023
  • The evaluation of fire risk for combustible materials was carried out using Chung's equations-X, Chung's equations-XI, and Chung's equation-XII, which were newly established. The fire risk index-XII (FRI-XII) and fire risk rating (FRR) were calculated for specimens including camphor tree, cherry, rubber tree, and elm. The combustion characteristics were determined using a cone calorimeter according to ISO 5660-1. Chung's equations caculated the fire performance index-X (FPI-X) and fire growth index-X (FGI-X) values ranged from 89.34 to 1696.75 s2 /kW and from 0.0006 to 0.0107 kW/s2 , respectively. In addition, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) varied from 0.08 to 1.48 and from 0.67 to 11.89, respectively. The fire risk index-XII (FRI-XII), which is an indicator of fire risk, showed that camphor tree had a value of 148.63 (fire risk rating: G), indicating a very high fire risk. This suggests that combustible materials with a high concentration of volatile organic compounds have lower FPI-X and FPI-XI values, higher FGI-X and FGI-XI values, and consequently higher FRI-XII values, indicating an increased fire risk.

Rating of Fire Risk of Combustible Materials by the New Chung's Equation-IX (새로운 Chung's equation-IX에 의한 연소성 물질의 화재 위험성 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.2
    • /
    • pp.144-152
    • /
    • 2023
  • To evaluate the fire risk of combustible materials, Chung's equations VII, VIII, and IX were newly established. The fire risk index-IX (FRI-IX) and fire risk rating (FRR) were calculated. Ginkgo, dawn redwood, toona, lime, walnut, and polymethylmethacrylate (PMMA) were selected as test specimens. The combustion characteristics were evaluated using a cone calorimeter according to ISO 5660-1. After combustion, the fire performance index-VII (FPI-VII) of the specimens, varied between 15.15 and 182.53 s2/kW, as determined by Chung's equations, and the fire growth index-VII (FGI-VII) varied between 0.0023 and 0.0165 kW/s2. The fire performance index-VIII (FPI-VIII) based on PMMA varied between 0.29 and 3.45, and the fire growth index-VIII (FGI-VIII) varied between 2.88 and 20.63. The FRI-IX, which is the fire risk rating, showed dawn redwood has a very high fire risk, with FRI-IX values of 71.14 (fire risk rating: G). Therefore, wood with a large amount of volatile organic compounds and a low bulk density showed a high value of FRI-IX by lowering FPI-VII and FPI-VIII and increasing FGI-VII and FGI-VIII.

Categorizing Safety Management Elements for Fire Preparation and Assessemnt of Fire Hazard (화재에 대비한 지하공간의 안전관리 요소분류 및 화재위험성 평가방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.96-109
    • /
    • 2011
  • In this study, risk categorized five safety management elements(equipment and structure, evacuation, lifesaving and fire extinguishing, performance based fire safety plan, operations management) were classified in order to establish safety system of underground space. Using classified safety management elements, assessment of fire hazard was performed. After calculating the grade of evaluation categories, assessment of fire hazard was suggested. The three grades of evaluation categories are classified as to importance and four criteria of evaluation are classified as to check result based on subdivisions.

A Study on the Characteristics & Fire Hazard of Electric Range (전기레인지의 특성과 화재 위험성에 관한 연구)

  • Lee, Jung-Il;Ha, Kag-Cheon;Kim, Ji-Myong
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.380-390
    • /
    • 2019
  • Purpose: Recently, in addition to increase in the use of electric ranges, fires have also been increasing. Method: To find out the fire risk of induction and highlights range, looked at the structure and operation methods. Combustion tests, heat transfer tests, and ignition tests were performed on both types. Results: The highlight electric range burned the towel two minutes later, takes about 25 minutes for the residual heat to cool down after cooking, and the energy of the red color disappeared in three to four minutes and no sparks were seen. Conclusion: Experiments have shown that burn and fire hazards exist, especially if there is cracks in the top, there is a risk of fire and explosion.

도장부스의 발화에 관한 연구

  • Guk, Jung-Gyun;O, Eun-Cheol;Heo, Seong-Gu;Park, Yeong-Geun
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.12a
    • /
    • pp.147-171
    • /
    • 2010
  • 도장작업은 기계 기구, 금속, 자동차, 전기 전자, 선박, 가구제조업 등 각종 사업장에서 많이 취급되고 있는 작업으로서 취급물질이 대부분 합성수지 유기용매 등 인화성 또는 가연성 액체이거나 가연성 분체로서 용매 또는 분진으로 인한 폭발 화재의 위험성이 아주 높은 실정이다. 보통 4류 위험물의 유증기는 공기보다 무겁다 라는 생각으로 발생된 모든 유증기는 위험물 인근에 체류할 것이라는 생각을 하지만 상온에서 증발한 유증기 대부분은 인근의 대기와의 밀도차에 의해 주변으로 흩어지거나 연소하고 중량(重量)의 유증기만이 남아 화재조사에서 중요한 단서로 역할을 한다. 대부분분의 페인트 제품이 가열과 동시에 끊기 시작해서 비등점 측정이 어려웠고 발화점이 비슷한 다른 페인트에 비해 중량(重量)유증기 발생이 단시간 동안 낮은 온도에서 많이 발생한 것은 페인트의 안료가 유증기 발생을 방해해서 시너의 유증기 발생량과 동일한 양의 페인트 유증기 발생시간이 더 걸린 것 같다. 대부분의 유증기는 집진시설을 통해 A/C타워의 활성탄에 흡착되어 제거된다. 하지만 슬러지에 남아있는 희석제는 A/C타워를 정지하고 집진시설등의 배관에 있는 슬러지 청소 과정에서 주위 열원에 의해 많은 유증기를 발생하여 화재의 위험성이 존재함으로 작업자의 각별한 주의가 필요하다.

  • PDF

A Study on the Electrical Fire Risk of Terminal Block Due to Single and Composite Cause (단일 및 복합 원인에 의한 단자대 전기화재위험성에 관한 연구)

  • Kim, Si-Kuk;Gum, Dong-Shin;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.57-66
    • /
    • 2015
  • This thesis is based on a research to investigate the electrical fire risk due to the single and composite cause in a terminal block. This paper analyzed the thermal characteristics depending on the screw torque change and contact resistance change to measure the fire risk due to the poor contact from single cause first. To measure the fire risk due to the composite cause, the acceleration tracking depending on the contact resistance change was experimented to check the correlation of poor contact and tracking to fire. The experiment result showed that the thermal characteristics were clearer as the screw torque in poor contact status and magnitude of contact resistance increased and that the thermal characteristics of terminal block depending on the contact resistance change was more reliable than the thermal characteristics depending on the screw torque change. Moreover, the terminal block poor contact and tracking were correlated in the case of the composite cause, and when two composite causes were interacted, the electrical fire risk was higher than the single cause.

Study on the Risk Analysis of Complex Electrical Fire by the Partial Disconnection and Tracking (반단선과 트래킹에 의한 복합적 전기화재의 위험성분석 연구)

  • Park, Sang-Min;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.111-118
    • /
    • 2017
  • The present paper is a study on the risk analysis of complex electrical fire by the partial disconnection and tracking. First, in order to analysis the single cause of electrical fire risk by the partial disconnection, the thermal characteristic has been measured by the change in the number of strands and the rated current of a wire. And then, in order to analysis the electrical fire risk by complex cause, an experiment on the accelerated tracking has been carried out in a condition of partial disconnection and confirmed the fire relation between partial disconnection and tracking. From the experiment, if the partial wire disconnection acts as a single cause, the existing thermal characteristics generated by the flowing current has appeared more clearly by the increase in the flowing current due to the complex action of tracking. Accordingly, the disconnection of strands has appeared by the complex cause due to the drastic temperature increase which was not generated in the single cause. Namely, it has been confirmed that if the partial disconnection and tracking act complexly rather than the risk of electrical fire by the existing partial disconnection, relatively its risk has been increased in large.