• Title/Summary/Keyword: 화재시나리오

Search Result 287, Processing Time 0.029 seconds

Analysis of Smoke Spread Effect Due to The Fire Location in Underground Subway-Station (대심도 역사의 화재위치에 따른 연기확산 영향 분석)

  • Jang, Yong-Jun;Koo, In-Hyuk;Kim, Jin-Ho;Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2885-2890
    • /
    • 2011
  • Simulation study were performed for fire location effect on the smoke spread in the deeply-underground subway station(DUSS). In this research, Shingumho station (The line # 5, Depth: 46m) has been selected as case-study for the analysis of smoke-spread effect with the different fire location. Field test data measured for actual fan in DUSS was applied as a condition of a simulation. The whole station was covered in this analysis and 4 million grids were generated for this simulation. The fire driven flow was analyzed case by case to compare the smoke-spread effect according to the fire location. In order to enhance the efficiency of calculation, parallel processing by MPI was employed and LES(large eddy simulation) method in FDS code was adopted.

  • PDF

Research of the Method for Required Fire Resistance of the Concrete Structures in Tunnel (터널에서의 콘크리트 구조물 내화성능 확보방안을 위한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Kim, Hyung-Jun;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.506-512
    • /
    • 2009
  • 최근 건설 중인 금정터널(총 연장 20.3km)이나 부산-거제간 침매터널은 화재 발생시 구조체의 강도저하로 인한 붕괴 및 사회기반시설인 교통망을 장시간 끊어놓은 등 큰 피해를 야기시킬 수 있다. 이러한 초장대터널이나 침매터널은 다른 터널보다 밀폐된 공간이므로 화재 시 단시간에 급격하게 온도상승이 일어날 수 있으며 이로 인해 구조물의 주재료인 콘크리트의 폭렬이 발생하고 구조물 내부까지 고온이 전달되어 경우에 따라 구조체의 붕괴의 원인이 되기도 한다. 따라서 본 연구에서는 콘크리트 구조체의 내화성능을 확보하기 위해 유럽에서 사용되고 있는 터널내화용 보드와 모르타르를 적용한 콘크리트의 내화성능 확보방안을 위한 시험을 수행하였다. 실험에 대한 내화성능 평가는 ITA(International Tunneling Association)에서 정한 화재 손상범위를 평가기준으로 하였고 터널화재 시나리오는 네덜란드의 TNO에 의해 실행된 실험결과를 따른 RWS 화재곡선을 이용하여 수행하였다.

  • PDF

Fire and Evacuation Simulation Analysis of Large-Scale Domestic Data Centers (국내 대규모 데이터센터 화재 및 피난 시뮬레이션 분석 )

  • Kim, Dong-Min;Go, Eun-Seong;Park, Hyeong-Gyoon;Gwak, Ji-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.347-348
    • /
    • 2023
  • 본 논문에서는 실제 규모 데이터센터의 3D 모델링을 기반으로 대상 공간별 화재 시나리오를 선정하여 화재 및 피난 시뮬레이션을 수행하였다. FDS와 Pathfinder는 full coupling 방식을 사용할 수 없는 한계가 있으며 semi coupling의 경우 가시화에는 도움이 되나 결과에 영향을 주지 않는다. 따라서 재실자의 피난 상황 시 경로에 대한 안전성과 화재 위험 노출 정도를 시각적으로 분석하는 것이 가능한 semi coupling과 시뮬레이션 결과 데이터 분석을 병행하여 수행하였다. 전산실의 경우 서버의 기능상실 한계 온도가 32도이기 때문에 서버 기능 정지 상황에 도달하는 시간을 중점적으로 분석하였다. 전산실은 업무 및 고객 서비스와 관련된 모든 데이터들을 저장하기 위해 항시 기동 되어야 하는데 전산실 내 화재가 발생할 경우 1~2분 이내 서버 기능이 정지되는 상황이 발생하였다. 따라서, 서버가 안전하게 계속 동작하기 위해서는 전력 계측 및 제어 케이블 열화, 서버 장치의 건전성이 유지되어야 하며 초기 화재를 빠르게 감지하여 진압하여야 한다. 피난 시뮬레이션의 경우 가시도를 상실하게 되는 시간이 약 195초(5m 미만) 인근으로 인원이 해당 층을 완전히 벗어나는 데 걸리는 시간이 약 125.6초였던 것을 보면 대피하기에 충분한 허용 피난시간(ASET)을 확보하고 있음을 알 수 있었다.

  • PDF

An Experimental Study on Thermal Damage and Spalling of Concrete Lining in Tunnel Fire (터널화재시 콘크리트 라이닝의 폭렬 및 화재손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Kyung-Suk;Lee, Jae-Sung;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.110-120
    • /
    • 2009
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F 2257-1. Referring to tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, $1^{\circ}C$/SEC, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 30mm under ISO fire condition, 20mm under $1^{\circ}C$/SEC, 100mm under MHC and 50mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS and MHC.

A Study on the Damage Range According to Leakage Scenarios in Natural Gas Pipeline of LNG Fueled Ship (LNG 추진선의 천연가스 배관에서 누출 시나리오에 따른 피해범위에 관한 연구)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.317-326
    • /
    • 2020
  • In this study, damages caused by flash fire, overpressure, and thermal radiation based on the sizes of leak holes were evaluated using the areal location of hazardous atmospheres when natural gas leaked owing to the damage of pipeline in a LNG fueled ship. In addition, environmental variables (wind speed, atmospheric temperature, and atmospheric stability) and process variables (pipe pressure and pipe length) were classified to analyze the damage impact ranges caused by various scenarios. From the results, the damage range caused by the environmental variables was the largest, followed by overpressure and thermal radiation. Additionally, for the process variables, regardless of the pressure, length, or size of the leak holes, the damage range attributed to flash fire was the most significant, and the damage range was high in the order of overpressure and thermal radiation, similar to the environmental variables. The larger the size of the leak holes, the higher the values of the environmental and process variables, and the higher the damage range caused by jet fire compared to the environmental variables.

Study on the Fire Safety Estimation for a Pilot LNG Storage Tank (PILOT LNG저장탱크의 화재안전성 평가에 관한 연구)

  • 고재선;김효
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.57-73
    • /
    • 2004
  • Quantitative safety analysis through a fault tree method has been conducted for a fire broken out over the spilling LNG from a pilot LNG tank, which may have 4 types of scenarios causing potentially risky results. When we consider LNG release from venting pipelines as a first event, any specific radius of Low Flammable Limit(LFL) has not been built up. The second case of LNG outflow from the rupture of storage tank which will be the severest has been analyzed and the results revealed various diffusion areas to the leaking times even with the same amount of LNG release. As a third case LNG leakage from the inlet/outlet pipelines was taken into consider. The results showed no significant differences of LFL radii between the two spilling times of 10 and 60 minutes. Hence, we have known the most affecting factor on the third scenario is an initial amount of LNG release. Finally, the extent of LFL was calculated when LNG pipelines around the dike area were damaged. In addition, consequence analysis has been also performed to acquire the heat radiation and flame magnitude for each case.

Feasibility Study on the Fire Scenario Design of a Couch Burning through a Fire Spread Model (화염 전파모델을 이용한 소파화재 설계화원구성의 적용성 연구)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The present study has been performed to examine the feasibility of a flame spread model on the design fire scenario for fire risk analysis. Thermo-Gravimetric analysis and sample burning test were conducted to obtain the material properties of a single couch covered with synthetic leather material and a series of FDS calculations applying with the measured material properties were performed for different grid sizes. The overall fire growth characteristics predicted by the fire model were quite different from the results of a real scale fire test and the initial peak value of the HRR and total released energy showed the results within a 30% discrepancy for the computational grids used in the present study. The current model has some limitations in predicting the fire growth characteristics, such as fire growth rate and the time to the maximum HRR. This study shows that the fire model may be applicable to creating the design fire scenario through continuous model improvement and detailed material properties.

Study on Design Technology for Disaster Management System for Super Long Span Bridge (초장대교량의 재난관리시스템 설계기술에 관한 연구)

  • Yun, Jung-Hyun;Kim, Moon-Ok;Jang, Min-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.437-440
    • /
    • 2010
  • 연육 연도교에 주로 건설되는 초장대교량은 시설물 특성상 이용객들의 대피공간이 제약받고 태풍, 해일 등 자연재해에 노출이 많기 때문에 다른 공공시설물보다 재난에 취약한 구조물이다. 최근 공공시설물의 건설동향은 구조물이 장대화 되어가고 있어 재난 발생시 예상 위험이 점점 더 커지고 있다. 본 연구는 국내외 장대교량의 재난사고와 재난관리 사례연구를 통해 초장대교량에서 관리되어야 할 재난을 정의하였다. 초장대교량의 재난은 자연재해와 인적재해로 구분할 수 있는데, 자연재해로는 안개, 강설, 결빙, 강풍, 지진, 해일이 있으며 인적재해로는 교통사고, 화재, 테러, 선박충돌, 구조물 파괴 및 재료열화가 있다. 또한 초장 대교량에서 발생 가능한 모든 사고의 잠재가능성을 분석하여 가상의 재난관리 시나리오를 작성하였다. 이 시나리오는 예방, 대비, 대응 및 복구로 구분되는 관리단계별 실행계획 수립에 기초를 제공하게 될 것이다.

  • PDF

A Study on the Fire Safety of a Hybrid Composite Train Carbody (하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구)

  • Kim, Jung-Seok;Lee, Duk-Hee; Jung, Woo-Sun;Cho, Sea-Hyun
    • Composites Research
    • /
    • v.21 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • This paper explains fire safety tests of a hybrid composite train carbody with carbon/epoxy sandwich bodyshell and stainless steel underframe. In this study, a large scale mock-up was used to evaluate the fire safety of the composite train carbody. The test was conducted to the bare composite carbody mock-up without interior facilities and the fully equipped one. Tile fire propagation and temperature distribution of the carbon/epoxy bodyshell and the glass phenol interior panels was evaluated under the real fire accident scenario. The test scenario was based on the DaeGu subway fire accident. From the tests, both the surface temperature of the interiors and the composite bodyshell wore lower than tile ignition temperature. In addition, the fire spread along the surface of the interiors and bodyshell was not occurred.

CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process (반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석)

  • Chun, Kwang-Su;Yi, Jinseok;Park, Myeongnam
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.35-44
    • /
    • 2021
  • The PR (Photo Resist) process in the semiconductor process is a process that uses a mixture of flammable substances. Due to the process equipment is installed in a clean room and when flammable substances leak, there is a high risk of suffocation, fire, and explosion. It is necessary to analyze the impact of accidents that may occur during operation and to evaluate whether the safety of workers can be guaranteed. In this study, the value of radiant heat and temperature change at the monitor point set up virtual inside the clean room was confirmed through CFD simulation of 10 leak and fire scenarios using the FLACS CFD - Fire Module. A fire that occurs inside a clean room transfers high radiant heat to the inter-story structure, but its scope is quite limited, and it is unlikely that it will collapse in a single fire accident. There was no scenario in which two stairs leading to the exit were exposed to high radiant heat at the same time due to a fire accident, therefore workers were able to escape in case of a fire. In addition, it was confirmed that the level of radiant heat and temperature rise rapidly decreased as they moved downstairs. According to the API 520 standard, workers exposed to 6.31 kW/m2 of radiant heat that workers can withstand for 30 seconds were confirmed that it was possible to sufficiently escape from the inside.