• Title/Summary/Keyword: 화재사

Search Result 222, Processing Time 0.023 seconds

고객 스스로 궁금증 실시간 해결

  • Korea Database Promotion Center
    • Digital Contents
    • /
    • no.9 s.76
    • /
    • pp.42-43
    • /
    • 1999
  • 사이버증권, 사이버 뱅킹에 이어 인터넷 열풍이 생명, 손해, 화재 보험업계에도 불고 있다. 대형 보험사들을 중심으로 급히 전담팀을 구성해 기존 홈페이지를 개편하거나 전용 보험 쇼핑몰을 구축하고 있다. 최근에는 인터넷만을 통해 보험을 판매하는 사이버보험사까지 탄생하는 등 보험업계도 피할 수 없는 사이버경쟁 시대에 돌입하고 있다. 국내 인터넷 보험 시장에 대해 살펴봤다.

  • PDF

Fire Patterns According to the Blood Hb-CO Concentration of Charred Bodies (소사체의 혈중 헤모글로빈-일산화탄소 농도에 따른 연소형태 연구)

  • Choi, Seung-Bok;Oh, Bu-Yeol;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.40-48
    • /
    • 2012
  • Fire patterns have been used to determine the origin and cause of fires in every setting imaginable. However, it is very difficult to identify fire patterns and causes from the fire-damaged remains of a devastated structure. If someone was killed by the fire, it is possible to identify fire patterns by analyzing the Hb-CO concentration in charred bodies of deceased as well as the pace of the fire. For example, a low level of Hb-CO concentration in the charred bodies indicate a rapid fire with accelerants and the death was caused by severe heat and thick toxic fumes. However, a high level of Hb-CO concentration in the charred bodies demonstrates that the fire was slow and/or there was a flameless form of combustion. Thus, it is possible to identify fire patterns through analyzing the level of Hb-CO concentration on the dead from the fire. In this study, the Hb-CO concentration in the charred bodies was from 3 % at the case of gas burning oneself to death to 93 % at the death caused by smoldering fire.

승강기용 구명호흡장치의 개발을 위한 실험적 연구

  • Jeong, Hwa-Jin;Gwak, Ji-Hyeon;Gu, Jae-Hyeon;Baek, Jong-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.9-10
    • /
    • 2013
  • 최근 산업의 고도화에 따른 건물의 고층화로 하나 또는 그 이상의 승강기를 보유한 건물들이 증가하고 있다. 이러한 건물에서 화재와 같은 긴급한 재난 발생 시 피난계단을 이용하여 탈출해야 한다는 상식에도 불구하고 본능적으로 승강기를 이용하여 대피하려는 경향이 뚜렷하다. 화재상황에서 승강기 이용 시 독성의 연기 유입으로 피난 활동이 어려우며, 전원 차단으로 정지 시 연기에 질식사할 확률이 급증한다. 따라서 승강기 내부로의 고립이나 승강기를 이용한 피난활동 시 연기로부터 안전한 호흡장치의 개발을 위한 연구를 진행하고자 한다.

  • PDF

A Study on the Measures of Fire Protection System of Historic Timber Architecture in Kangwon-Do (강원도지역 중요목조문화재 소방대책에 관한 연구)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.446-449
    • /
    • 2011
  • 2005년 낙산사 이후 강원도 지역의 목조문화재의 소방대책 및 안전의식의 증대와 함께 많은 소방시설의 보강 및 정비가 이루어 졌다. 그럼에도 2008년 숭례문화재가 발생하는 등 목조 문화재의 손실이 발생하고 있다. 이 논문에서는 강원도에 위치한 중요 목조 문화재를 중심으로 목조 문화재의 소방 시설을 비교하고 삼척시에 위치한 죽서루를 중심으로 소방 현황과 대책에 대해서 알아보고 목조문화재의 화재 예방 및 소방대책에 대하여 제안하고자 한다.

  • PDF

A Numerical Study for the Atrium Smoke Control by Fire Shutter and Evacuation (방화셔터를 이용한 아트리움 제연과 피난안전에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.50-59
    • /
    • 2010
  • Four fire scenarios, as the cases of fire sizes of 2 MW and 5 MW, and no installation and activation of atrium fire shutter for dormitory building of Daegu 'D college', were developed and fire simulations were run using FDS (ver. 5.5.0) and Pathfinder 2009 programs. By assessing fire and evacuation, the effects of atrium fire shutter and vents on the smoke control of atrium were evaluated and this study also analyzed fire hazard and egress safety for occupants in the dormitory. Fire shutter's preventing smoke transport around atrium was much effective, but smoke layer descended down the design limit of smoke height and kept about 2 m height from the atrium floor in all cases because flow rate through vents was not enough. For the case of 5 MW fire and no fire shutter, fire hazard was higher due to visibility than temperature and allowable egress time to stairwell was short less than 5 seconds for the occupants on the floors of 4F to 7F. For total occupants, egress time out of main doorway was calculated about 136 seconds. It is sure that additional systems improving the performance of smoke control need to be installed for more safe evacuation.

The Study of fire Driven flow and Smoke Exhaust Efficiency for PSD Installation Subway Station (PSD 설치역사의 화재유동 및 배연 효율 연구)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1054-1061
    • /
    • 2009
  • This research was performed with emphasis on fire driven flow behavior and smoke exhaust efficiency which depend on the presence of PSD which are being installed domestically and overseas. For simulation, Jung-ang-ro station of Dae-gu subway station was chosen as model, and fire driven flow analysis was performed by using FDS as flow analysis code. Since many calculation time are required for calculation due to increase in the number of grid as the entire station is modeled, simulation was conducted in parallel processing technique. The fire driven flow analysis was analyzed case by case with composing fire scenario to compare fire driven flow and smoke exhaust efficiency changes depending on the presence of PSD. For fire scale, fire strength of 10MW was studied by referring to NFPA-l30. The calculation results were analyzed with focus on passenger safety by referring to NFPA-130.

  • PDF

A Study on the Application of Fire Risk Assessment Index on the Wooden Cultural Properties -focused on buddhist temples- (목조 건축문화재의 화재위험도 평가지표 및 활용방안 연구 -사찰 건축물을 중심으로-)

  • Kang, Seok-Jin;Ko, Myong-Hwan;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3550-3561
    • /
    • 2013
  • The purpose of this study was to propose the categorized checklist for fire risk assessment on the wooden cultural properties and to carry out field survey. The survey checklist was composed of categories such as management and administration measures(management, training and countermeasure), architectural planning measures(site plan and facility plan), and equipment measures(fire-fighting and crime prevention facility). In this study, the field survey was carried out in the Nae-jang-sa and Wha-um-sa and it was found that there were some problems in the items which were assessed importantly by experts.

VTS 관제구역 해양사고 분석

  • Yu, Sang-Rok;Kim, Ji-Gwan;Jeong, Jae-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.568-570
    • /
    • 2012
  • 해양사고는 충돌, 좌초, 접촉, 화재, 폭발, 침몰, 전복, 인명사상, 손상 등으로 분류할 수 있다. 이 중 관제사와 관련있는 것은 충돌사고다. VTS 관제구역내 최근 10년간 발생한 충돌사고를 재결서를 통해 분석하였다. 충돌사고 분석으로 각 VTS별 관제 주안점을 정리하여, 신임관제사 및 전입자에게 OJT 교육자료로 활용하고자 한다.

  • PDF

Comparison of Effectiveness on Hospital-based Skill Training in Level 2 Emergency Medical Technician (2급 응급구조사 병원임상실습교육 효과 비교)

  • Kim, Dong-Ok
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.104-109
    • /
    • 2014
  • This study is analysis of the effectiveness and satisfaction index of hospital-based skill training (HST) in level 2 emergency medical technicians. The purpose of this study is to provide basic data for the effective operation. The survey carried out to 70 level 2 emergency medical technicians who participate in HST from July 29 to August 22 in 2013. From the study, self evaluated operation skills scale were 3.09 before training and 3.80 after training. It showed statistically significant enhancements. satisfaction index were 3.80. appopriate education periods were (1~2) weeks (64.3%). the longer the time had been since their training completion, the higher education satisfaction. The multilateral studies on problems and needs of HST and development of training programs that includes hospital training monitoring are necessary.

공동주택 전용 유수검지장치의 성능개선에 관한 연구

  • Gang, Won-Seon;Son, Bong-Se;Jeong, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.169-170
    • /
    • 2013
  • 공동주택은 단독주택과는 달리 대지와 건물의 계단, 벽 등을 공동으로 사용하지만 각 세대별로는 독립된 주거생활을 영위할 수 있도록 건축된 소방대상물로서 아파트, 연립주택, 다세대주택 및 기숙사 등이 이에 해당된다. 공동주택은 대부분 단지 내 기계실에서 전 세대에 소화수를 공급하고 있기 때문에 부재중인 세대와 사생활침해 등의 이유로 출입이 자유롭지 못한 세대로 인하여 스프링클러의 점검 작업 시 많은 어려움을 겪고 있다.

  • PDF