• Title/Summary/Keyword: 화염직경

Search Result 54, Processing Time 0.033 seconds

Combustion Characteristics of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns (이중 콘형 부분 예혼합 GT 노즐의 연료 분사구 형상 변화에 대한 연소특성)

  • Kim, Han Seok;Cho, Ju Hyeong;Kim, Min Kuk;Hwang, Jeongjae;Lee, Won June
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.25-31
    • /
    • 2020
  • Experimental investigations were conducted to examine the combustion characteristics of a swirl-stabilized double cone premixed burner nozzle used for industrial gas turbines for power generation. Several variants with different fuel injection patterns are tested to compare the combustion characteristics such as NOx and CO emissions, stability, and wall temperature distributions. Main results show that NOx emissions and stability are decreased either when the fuel hole diameter is decreased with the same number of fuel holes, or when the number of fuel holes is reduced with the same total area of fuel holes, both of which are due to a higher penetration of fuel into the air stream. Not only is NOx reduced but also stability is enhanced when the fuel hole diameter varies in an alternating manner with the same total area of fuel holes, showing that NOx reduction is due to a higher penetration of mean fuel injection path while stability enhancement is due to a lowered penetration of minimum fuel injection path.

Characteristics of Far Infrared Heater for Grain Drying (곡물 건조용 원적외선 방사체의 특성)

  • 이호필;김유호;한충수;연광석;조성찬;이재석;조영길;최태섭
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.349-354
    • /
    • 2002
  • 쌀 소비량은 생활 수준 향상과 외식 및 식품 산업의 발달로 감소하고, 고품질 쌀을 요구하는 성향이 높아지고 있다. 현재, 고품질 쌀을 생산할 수 있는 기술과 제반 요건은 구비되어 있으나, 수확 후 건조·저장 중에 쌀의 품질이 저하된다. 특히 건조 중 품질 저하는 고온건조에 의한 동할 발생 및 과건조가 주요 원인이다. 이를 해결하기 위해 원적외선 건조 시스템에 관한 연구가 진행 중이다. 본 연구에서는 방사율이 높고, 접착성 및 내열성 등이 강한 곡물 건조기용 방사체 코팅원료를 개발하고, 이 원료를 원적외선 방사체에 코팅한 후 방사체의 형태와 크기에 따라 표면 온도 분포 및 연료 소비량 등을 측정 분석하여 방사체의 특성과 적정 조건을 규명하고자 하였다. 연구 결과를 요약하면 다음과 같다. (1) 세라믹 코팅 원료의 배합비는 세라믹분말 40%와 결합재 60%가 접착력과 가열경화 후 표면이 양호한 것으로 나타났다. (2) 노즐의 유량 및 분무각에 따른 버너의 화염길이 및 폭은 노즐유량이 증가함에 따라 증가하는 경향을 나타내었다. (3) 방사체 위치별 표면온도편차는 방사체 길이가 1350mm인 것이 작은 것으로 나타났고, 열풍유동관 직경이 Rounding type의 경우 76.3mm, Right angle type의 경우 89.1mm일 때 표면 온도편차가 적었다. (4) 연료소비량은 열 풍유동관 직경이 클수록, 방사체 길이가 길수록 증가하는 경향을 나타내었고, Right angle type이 Rounding type에 비하여 연료소비량이 약간 높은 것으로 나타났다.

  • PDF

Stabilization Characteristics of the Diffusion Flame Formed in the Wake of Bluff Body with Fuel Injection (연료분출을 수반하는 보염기 후류에 형성되는 확산화염의 보염특성)

  • 안진근
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.223-232
    • /
    • 2001
  • To study the stabilization characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection, the flame stability limits, length and temperature of recirculation zone of flame, turbulence intensity distribution near the recirculation zone of flame were measured and analyzed. The length of recirculation zone is independent on main fuel injection quantity, but it is dependent on fuel injection angles, air stream velocity, and auxiliary fuel injection into recirculation zone. For diffusion flame, in general, the flame stabilization is deteriorated with increase of he length of recirculation zone, but if the turbulence generator is installed, the flame stabilization is improved with increase of the length of recirculation zone. The temperature of recirculation zone is dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it has a maximum value at the condition of each theoretical mixture. In general, the more temperature of recirculation zone is low, the more flame is stable. But when the turbulence generator is installed, the more temperature of recirculation zone is low, the more flame is unstable. The turbulence intensity in the wake of bluff body is increased with increase of diameter or blockage ratio of grid. The more turbulence intensity is increased by installation of turbulence generator, the more flame is unstable. Finally, It is clear that the stabilization characteristics of diffuser flame can be controlled by some parameters such as fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators.

  • PDF

Analysis of effect of hydrogen jet fire on tunnel structure (수소 제트화염이 터널 구조체에 미치는 영향 분석)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2021
  • A policy to expand the hydrogen economy has been established in Korea and the supply of FCEV is being expanded to realize a hydrogen society. Therefore, the supply of FCEV is expected to increase rapidly, and a solution to respond to accidents of FCEV is required. In this study, an experimental study was conducted to analyze the effect of the hydrogen jet flame generated by a FCEV on the inner wall of the tunnel and the characteristics of the internal radiant heat. For the experiment, the initial pressure of hydrogen tank was set to 700 bar, and the injection nozzle diameter was set to 1.8 mm in order to make the same as the conditions generated in the FCEV. In addition, a tunnel fire resistance test specimen having the same strength as the compressive strength of concrete applied to general tunnels of 40 MPa was manufactured and used in the experiment. The results were analyzed for the separation distance (2 m and 4 m) between the hydrogen release nozzle and the tunnel fire resistance test concrete. As the result, the maximum internal temperature of the test concrete was measured to 1,349.9℃ (2 m separation distance), and the radiant heat around the jet flame was up to 39.16 kW/m2.

A Study on the Development of After Burner in Inert Gas Generator (비활성 가스 제네레이터의 후방연소기 개발에 관한 연구)

  • Kim, H.K.;Ahn, K.Y.;Kim, H.S.;Lim, I.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.909-914
    • /
    • 2001
  • After burner which is main part of inert gas generator(IGG) is studied for the development of IGG. The results of many experimental equations are applied to estimate characteristics of the spray nozzle and evaporation of spray, and selected the optimum design point of after burner. The selected design point of after burner are validated experimentally through the pilot plant of after burner. The flame stability is favorable at design point(150mm), that distance from stabilizer to nozzle. The emission of $NO_x$ and CO is lower than gas turbine combustor which was used in primary combustor.

  • PDF

A Numerical Study of Water Mist Behavior According to Droplet Diameter-Size (입자 직경에 따른 물분무수 거동 특성에 관한 수치적 연구)

  • Lee, Dong-Chan;Jung, Woo-Sung;Lee, Cheul-Kyu;Lee, Duck-Hee;Jang, Yong-Jun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.415-419
    • /
    • 2008
  • In this study, analysis of water mist behavior is performed using numerical simulation. Water mist is characterized by the droplet flow which is one of the multiphase flows and is discrete fluid droplets in continuous air. It is important to choose the proper diameter of droplet-size and the distance between the fire location and the position of water mist because it depends on the buoyancy from fire. Therefore the behavior of water mist with fire should be simulated by FLUENT, a commercial computational fluid dynamics(CFD) program, with Lagrangian discrete phase model. (DPM)

  • PDF

The Effect of Bluff-Body Shapes on the Drop Size and Flame Temperature (Bluff-Body형상이 연료액적크기와 화염온도에 미치는 영향)

  • Hwang, Sang-Ho;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.937-942
    • /
    • 2000
  • The characteristics of spray combustion and dropsize of spray through twin-fluid atomizer was experimentally investigated. The distribution of flame temperature have an effect on the generation of NOx. To investigate there effects, flame temperature with different spray shape was observed. The spray shape was varied by various bluff-bodys. Mean temperature were measured by thermocouple respectively, and NOx concentration was measure by NOx analyser. Distribution of droplet sizes were measured by PMAS. The result showed that the flame with wide distribution has lower temperature and lower NOx emission compared with narrow.

  • PDF

Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space (수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구)

  • Baek, Doo-San;Kim, Hyo-Gyu;Park, Jin-Yuk;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2021
  • Hydrogen in hydrogen-electric vehicles has a wide range of combustion and explosion ranges, and is a combustible gas with a very fast flame propagation speed, so it has the risk of leakage, diffusion, ignition, and explosion. The fuel tank has a Thermally active Pressure Relief Device (TPRD) to reduce the risk of explosion and other explosions, and in the event of an accident, hydrogen inside the tank is released outside before an explosion or fire occurs. However, if an accident occurs in a semi-closed space such as an underground parking lot, the flow of air flow is smaller than the open space, which can cause the concentration of hydrogen gas emitted from the TPRD to accumulate above the explosion limit. Therefore, in this study, the leakage rate and concentration of hydrogen over time were analyzed according to the diameter of the nozzle of the TPRD. The diameter of the nozzle was considered to be 1 mm, 2.5 mm and 5 mm, and ccording to the diameter of the nozzle, the concentration of hydrogen in the underground parking lot increases in a faster time with the diameter of the nozzle, and the maximum value is also analyzed to be larger with the diameter of the nozzle. In underground parking lots where air currents are stagnant, hydrogen concentrations above LFL (Lowe Flammability Limit) were analyzed to be distributed around the nozzle, and it was analyzed that they did not exceed UFL (Upper Flammability Limit).

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (IV) -Torch Ignition (2) - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (IV) -토치 점화 (2)-)

  • Ko, Ansu;Ohm, Inyong;Kwon, Soon Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.135-146
    • /
    • 2015
  • This paper is the fourth on the combustion characteristics of the landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine and the second dealing with torch ignition. It discusses the combustion characteristics of torch ignition on the basis of the heat release and visualization. The results show that the jet and/or spout from the torch promote combustion by accelerating the flame front in the main combustion chamber. In addition, a hot gas jet exists when the orifice diameter is 4 mm, whereas the flame passes directly through the orifice if the diameter is 6 mm or greater. In addition, the effect of torch ignition differs according to the combination of the methane fraction, torch volume, and orifice size because various combustion processes occur as a result of the interaction of these parameters. Finally, it was found that the most suitable torch should have an orifice diameter of not less than 6 mm and an area ratio of not more than 0.15 to secure a consistent combustion process in a real engine.

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.