• Title/Summary/Keyword: 화염길이

Search Result 116, Processing Time 0.022 seconds

Flame Length Scaling in a Non-premixed Turbulent Diluted Hydrogen Jet with Coaxial Air (희석된 동축공기 수소 난류확산화염의 화염 길이 스케일링)

  • Hwang, Jeong-Jae;Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.242-245
    • /
    • 2009
  • The effect of fuel composition on flame length was studied in a non-premixed turbulent diluted hydrogen jet with coaxial air. The observed flame length was expressed as a function of the ratio of coaxial air to fuel jet velocity and compared with a theoretical prediction based on the velocity ratio. Four cases of fuel mixed by volume were determined. In the present study, we derived a scaling correlation for predicting the flame length in a simple jet with coaxial air using the effective jet diameter in the near-field concept. The experimental results showed that visible flame length had a good relation with the theoretical prediction. The scaling analysis is also valid for diluted hydrogen jet flames with varied fuel composition.

  • PDF

Experimental Investigations of the Characteristics of the Length Variation of Kerosene-Oxygen Laminar Diffusion Flames (등유-산소 층류 확산화염의 길이 변화 특성에 관한 실험적 연구)

  • Lee, Soo-Han;Lee, Jong won;Park, Seul Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • The flame length in coaxial diffusion flame configurations was investigated when the kerosene fuel flow rate, temperature of the oxidizer stream, and inert gas concentrations in the oxidizer stream were varied. The diffusion flame was photographed using a Schlieren camera under each of the experimental conditions and the obtained images were then digitized to measure the flame length. The measured flame lengths were proportional to the kerosene fuel flow rate and increased with increasing temperature of the oxidizer stream. In addition, increases in the inert gas concentration in the oxidizer stream resulted in stretching of the flame. In particular, the flame was further elongated in the oxidizer steam diluted with helium gas. Inert substitutions in the oxidizer stream that can adjust the viscous drag are believed to be one of the important mechanisms that affect the length of the coaxial diffusion flames.

An experimental study on the structure of the jet flame in cross flow (균일 유동장에 수직으로 분사된 제트화염의 구조에 대한 실험적 연구)

  • 유영돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.84-89
    • /
    • 1994
  • 주유동에 수직으로 분사된 제트 화염의 구조는 이해하기 위하여 화염 길이와 온도를 측정하고 reactive mie scattering 방법을 이용하여 단면 가시화를 실시하였다. 주유동 속도와 제트 분사 속도의 증가에 따라 화염 길이도 함께 증가함을 알 수 있고, 단면 가시화 결과 화염 내부에 존재하는 inner vortical structure는 일반적인 동축제트 화염과 같은 대칭 구조를 갖지 앉고 유동 조건에 따라 inner vortical motion 의 생성 위치가 변화함을 알 수 있다 이는 본 유동장의 특성 중의 하나인 bound vortex와 제트와 주유동이 접하는 상류 면에서 발생하는 rolling-up 의 강도에 좌우됨을 알 수 있다.

  • PDF

Effects of Flow Excitation on the Nitrogen Oxide Emission of a Non-Premixed Flame (유동장 자극이 화염의 질소산화물 배출에 미치는 영향)

  • 이기만
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.34-40
    • /
    • 2004
  • The effects of external flow excitation with various frequencies and amplitudes on the flame behavior and pollution emission characteristics from a laminar jet flame are experimentally investigated. Measurements of $NO_x$ emission indices ($EINO_x$), performed in vertical lifted flame like turbulent with various exciting amplitude at a constant resonance frequency, have been conducted. It was also conducted to investigate the effects of excited frequency at a constant exciting amplitude on $NO_x$ emissions with a various frequency ranged 0 Hz to 2 KHz. From the vertical lifted turbulent flame of the excited jet with resonance frequency by strong excitation was shown that the dependence of $NO_x$ emission could be categorized into three groups Group I of long flame length with high disturbances yielding high $NO_x$ emission, Group II of intermediate flame length and relative narrow flame volume with low disturbance yielding low $NO_x$ emission and Group III of long flame length and large flame volume with high time & space disturbances behaviour yielding high $NO_x$ emission.

Combustion Characteristics of the Methane-Oxygen Bipropellant Injected by a Shear-coaxial Injector (전단동축형인젝터를 통해 분사된 메탄-산소 이원추진제의 연소특성)

  • Hong, Joon Yeol;Bae, Seong Hun;Bae, Dae Seok;Kim, Jeong Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.787-790
    • /
    • 2017
  • This study is a preliminary research on characterization of methane - oxygen combustion used in bipropellant thruster. The limit of combustion stability and flame shape of methane - oxygen non-premixed flame injected by shear coaxial injector in the model combustion chamber Experimental studies have been carried out. A direct image of the flame was photographed using a DSLR camera, and combustion characteristics and flame length were quantified through image post-processing. As a result, it was confirmed that the stabilized flame was generated at the stoichiometric ratio as the oxidizer Reynolds number ($Re_o$) was increased, and the length of the turbulent flame was increased under the same injector diameter condition.

  • PDF

Investigation of the Prediction Performance of Turbulence and Combustion Models for the Turbulent Partially-premixed Jet Flame (난류 부분예혼합 제트화염에 대한 난류 및 연소모델의 예측성능 검토)

  • Kim, Yu Jeong;Oh, Chang Bo
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.35-43
    • /
    • 2014
  • The prediction performance of 9 model sets, which combine 3 turbulent models and 3 combustion models, was investigated numerically for turbulent partially-premixed jet flame. The standard ${\kappa}-{\varepsilon}$ (SKE), Realizable ${\kappa}-{\varepsilon}$ (RKE) and Reynolds stress model (RSM) were used as a turbulence model, and the eddy dissipation concept (EDC), steady laminar flamelet (SLF) and unsteady laminar flamelet model (ULF) were also adopted as a combustion model. The prediction performance of those 9 model sets was evaluated quantitatively and qualitatively for Sandia D flame of which flame structure was measured precisely. The flame length was predicted as, from longest to shortest, RSM > SKE > RKE, and the RKE predicted the flame length of the jet flame much shorter than experiment. The flame temperature was over predicted by the combination of RSM + SLF or RSM + ULF while the flame length obtained by RSM + SLF and RSM + ULF was well agreed with the experiment. The combination of SKE + SLF and SKE + ULF predicts well the flame length as well as the temperature distribution. The SKE turbulence model was most superior to the other turbulent models, and SKE + ULF showed the best prediction performance for the structure of turbulent partially-premixed jet flame.

The Characteristics of Unconfined Hydrogen Diffusion Flames in Supersonic Air Flows (초음속 공기 유동장에서의 수소 확산 화염 특성에 대한 연구)

  • 김제흥;심재헌;김지호;윤영빈
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.78-86
    • /
    • 2000
  • The objective of this research is to understand the characteristics of a nonpremixed, turbulent, hydrogen jet flame which is stabilized in Mach 1.8 coflowing air flows. In order to investigate the flame structure, flame lengths and fuel trajectories were measured by using direct photography, acetone PLIF, Mie scattering techniques, and numerical simulation. Effect of increasing air velocity was investigated when fuel velocity is fixed. The subsonic flame length was decreased drastically, however the supersonic flame length was increased slowly Then the change of flame blow out characteristics was observed as varying fuel nozzle lip thickness. The flame stability can be increased when fuel nozzle lip thickness was increased, which indicates that the minimum fuel lip thickness ratio is required for the stable supersonic flames. Also, it is found that fuel jet is blocked by high pressure zone and low scattering zone is made. Then the fuel that was moving along the recirculation zone had longer residence time within the supersonic flames, which made partially premixed zone.

  • PDF

Combustion Characteristics of a Gaseous Methane-Gaseous Oxygen Diffusion Flame Sprayed by a Shear Coaxial Injector (전단 동축형 인젝터를 통해 분사된 기체메탄-기체산소 확산화염의 연소특성)

  • Hong, Joon Yeol;Bae, Seong Hun;Kwon, Oh Chae;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.41-48
    • /
    • 2017
  • The combustion characteristics of gaseous methane-gaseous oxygen, an eco-friendly bipropellant injected by shear coaxial injector, were investigated. Flame was photographed under various combustion conditions using a DSLR camera, and the characteristics of the flame shape was quantified by image post-processing. From the view point of stabilization, the diffusion flame could be divided into anchored flame regime and blow-off regime. As the oxidizer Reynolds number ($Re_o$) increased, a probability of the formation of anchored flame increased with the length of flame. The shear coaxial injector used in this experiment was found to require a large length-to-diameter ratio of combustion chamber because it formed a relatively long flame in the injection direction due to a poor mixing depending only on the momentum diffusion of two propellant jets.

A Study on the Combustion Characteristics of Diffusion Flame with the Fuel Injection Condition (연료분출 조건에 따른 확산화염의 연소특성에 관한 연구)

  • Lee, Sung-No;An, Jin-Geun
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.300-307
    • /
    • 2007
  • The combustion characteristics of diffusion flame formed in the wake of a cylindrical stabilizer with varying fuel injection angle were studied. This study was performed by measuring the flame stability limits, lengths and temperatures of recirculation zones of flames, turbulence intensity in the wake of stabilizer, and concentration distribution of combustion gas, and by taking photographs of flames. The flame stability limits are dependent on fuel injection angle and main air velocity. The length and temperature of recirculation zone are dependent on fuel injection angle. As the length of the recirculation zone is decreased, the flame shows more stable behavior. The temperature of recirculation zone has a maximum value at the condition of theoretical mixture. The flame stability is enhanced when the temperature in the recirculation zone decreases. The turbulence intensity in the wake of stabilizer is independent of the fuel injection angle, but it is affected by stabilizer itself and main air flow condition. If the stabilization characteristics of flame is good, the concentration of $C_3H_8$ is high, but the concentration of $CO_2$ is low at the boundary of recirculation zone. The combustion characteristics of diffusion flame can be controlled by changing the fuel injection angles. The appropriate fuel injection angle should be selected to get high combustion efficiency, high load power, low environmental pollution, and clean combustion condition of fuel.

  • PDF

Experimental Study of Flow Characteristics with Swirl Number on Dump Combustor (모형 가스터빈 연소기에서 스월수에 따른 유동 특성에 관한 실험적 연구)

  • Park, Jae-Young;Han, Dong-Sik;Kim, Han-Seok;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.338-345
    • /
    • 2011
  • The swirl flow applied for high efficiency and reduction of emission such as NOx, CO in a gas turbine engine makes recirculation zone by shear layer in the combustion chamber. This recirculation zone influences a decreasing flame temperature and flame length by burned gas recirculation. Also it is able to suppress from instability in lean-premixed flame. In this study, it was found that the swirl flow field was characterized as function of swirl number using PIV measurement in dump combustor. As increasing swirl number, a change of flow field was presented and recirculation zone was shifted in the nozzle exit direction. Also turbulent intensity and turbulent length scale in combustor were decreased in combustion. It has shown reduction of eddies scale with swirl number increasing.