• Title/Summary/Keyword: 호흡주기

Search Result 203, Processing Time 0.03 seconds

Comparison of Daytime Sleepiness between Normal Subjects and Patients with Sleep Disorders and Analysis of Its Clinical Implications (정상인과 수면장애 환자군 간의 주간졸림증 비교 및 임상적 의미 분석)

  • Lee, Jin-Sung;Kim, Seog-Ju;Choi, Jong-Bae;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.2
    • /
    • pp.106-114
    • /
    • 2002
  • Objectives: Daytime sleepiness is a common symptom and is associated with sleep behavior, sleep deprivation, and night shift, etc. It is also one of the most important symptoms of sleep disorders like obstructive sleep apnea (OSA). According to our survey on Korean literature, a few studies have dealt with daytime sleepiness, and we have not been able to locate any study comparing normal subjects with polysomnography-proven sleep disorder patients regarding daytime sleepiness. We aimed at comparing daytime sleepiness among normal healthy daytime workers, medical students being expected to have daytime sleepiness due to chronic sleep deprivation, and patients having sleep disorders diagnosed with polysomnography. We also studied the association between subjective daytime sleepiness and objective polysomnographic findings in patients with sleep disorders. Methods: One hundred three hospital workers, 137 medical students, and patients with sleep disorders were studied. Sleep disorders included OSA, periodic limb movements in sleep (PLMS), insomnia, and narcolepsy. The degree of subjective sleepiness in each group was measured by the Korean version of Epworth sleepiness scale and compared. The relationship between polysomnographic findings reflecting severity of sleep disorder in each patient group and subjective sleepiness was analyzed. As for patients with narcolepsy, the relationship between the mean sleep latency and subjective sleepiness was studied. Results: There was a significant difference of ESS score (F=68.190, dF=5.752, p<0.001) among daytime workers, medical students, and sleep disorder patients. In OSA patient group, the degree of the sleepiness had no significant correlation either with mean O2 satuaration (p=0.062) or with RDI (p=0.807). In PLMS patient group, there was no correlation between periodic limb movement index (PLMI) and subjective sleepiness (p=0.761). In narcolepsy patient group, the subjective sleepiness had no correlation with mean sleep latency measured with MSLT (p=0.055). Conclusion: We found a significant difference of subjective sleepiness among daytime workers, medical students, and patients with sleep disorders. However, no consistent correlation was found between severity of subjective sleepiness and objective polysomnographic findings reflecting severity of each sleep disorder. This research confirms that the evaluation of subjective sleepiness is important clinically, but it cannot substitute the objective measures such as nocturnal polysomnography and MSLT.

  • PDF

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Respiration in the Adult of the Water Striders, Gerris paludum insuralis(Insecta, Hemiptera, Gerridae) (소금쟁이(G. paludum insuralis)성체의 흐름)

  • Park, Sang-Ock;Joo, Eun-Young
    • The Korean Journal of Zoology
    • /
    • v.29 no.3
    • /
    • pp.201-207
    • /
    • 1986
  • The authors attempted to investigate the oxygen consumption rate of sexuals in the water-striders, Gerris paludum insuralis, at four temperature groups of 25, 30, 35 and $40^\\circ C$ in a series of studies on respiration of a heminetabolous insects. THe results are summarised as follows: (1) At $30^\\circ C$, the change of oxygen consumption rate according to the lapse of time was small in comparison with the other three temperature groups which shows a cyclic decreasing pattern. The rate during initial and final 5 minutes was much alike. Thereupon, the optimum temperature was regarded as $30^\\circ C$. (2) The oxygen consumption rate of male was higher than that of female. (3) The oxygen consumption rates at 25, 30, 35 and $40^\\circ C$ were 0.42, 0.49, 0.79 and 1.11 $\\mu$l/mg/h respectively. That is, the rate was increased as the temperature was increased. (4) The $Q_10$ of male showed a high value in the lower temperature interval ($25^\\circ C \\sim 35^\\circ C$), but the female showed a high value in the higher temperature interval ($30^\\circ C \\sim 40^\\circ C$). The mean $Q_10$ was 2.12. (5) The respiratory rate was decreased as the body weight was increased in the above fresh weight of 10mg and dry weight 5 mg. (6) The upper temperature threshold for respiration was $48.31^\\circ C$ and the lower temperature threshold was $17.68^\\circ C$. (7) The ceasing time of breathing at the other three temperature groups except $30^\\circ C$ was infered to be about 110 minutes after the start of experiment.

  • PDF

computer-aided-diagnosis by image subtraction in conventional radiography (단순 x선 영상의 차영상을 통한 컴퓨터 도움 진단)

  • 김승환;이수열;박선희;표현봉
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.425-427
    • /
    • 1999
  • 본 논문에서는 시간 간격을 두고 활영한 흉부의 단순 x선 영상의 차영상을 이용하여 컴퓨터 도움 진단에 활용할 수 있는 방법에 대해 연구하였다. 시간 간격을 두고 촬영한 흉부 단순 x선 영상의 차영상은 시간에 따른 변화를 명확히 보여줌으로써 질병의 조기진단 및 질병의 전개과정 등을 알아보는데 유용하게 쓰일 수 있다. 특히, 이 방법은 폐암과 같이 조기진단이 매우 어려운 질병에 대하여 정기검진 등에서 정기적으로 촬영한 단순 x선 영상을 이용하여 조기진단을 할 수 있는 방법으로 활용될 수 있다. 그러나, 촬영시의 여러 가지 조건들, x선의 세기와 조영시간, 환자의 촬영 자세 및 호흡 상태 등에 따라 단순 x선 영상이 크게 달라져 단순한 뺄셈에 의한 차영상은 진단에 도움이 되지 못한다. 진단에 도움을 주기 위해서는 두 영상 사이의 전체적인 밝기와 대조도를 맞추고 늑골, 쇄골 등 해부학적 구조물의 위치와 크기를 서로 맞추어 차영상을 얻는 영상처리 방법이 필요하다. 또한, 폐의 크기와 위치도 서로 맞추어 차영상을 얻어야 한다. 그러나, 이러한 방법도 늑골과 폐의 크기와 위치 변화가 서로 일치하지 않는 문제점을 가지고 있다. 본 논문에서는 이러한 영상처리를 통하여 차영상을 얻는 방법에 대하여 논하고 방법상의 문제점과 해결 방법을 제시한다.

  • PDF

A Case of Dyspnea due to Endobronchial Metastasis from Rectal Cancer (주기관지내 전이에 의해 호흡곤란을 일으킨 직장암 1예)

  • 이정익;신성준;손장원;양석철;윤호주;신동호;박성수;장세진
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.2
    • /
    • pp.204-208
    • /
    • 2000
  • Endobronchial metastases from extrathoracic primary malignancies are uncommon. Breast, renal, and colonic carcinomas are primary sites most likely to give rise to endobronchial metastases. A number of other tumours have been reported as being complicated by endobronchial metastasis, including ovarian, thyroid, uterine, adrenal, testicular and prostatic carcinomas. The incidence of endobronchial metastasis has been estimated at 2% in patients who died of metastatic disease. Lung parenchymal metastases are common manifestations in patients with rectal cancer, however spread to the major airway is extremely rare. We herein report a case of endobronchial metastasis from rectal adenocarcinoma. A 69-year-old male patient who had been previously treated with surgical resection with rectal cancer presented with a 8-month history of gradually increasing dyspnea and non-productive cough. Clinical and radiological investigations revealed endobronchial metastasis involving, and penetrating, the lower carina and the left main bronchus. We confirmed endobronchial metastasis from the rectal carcinoma by bronchoscopic biopsy.

  • PDF

A Case Report of Lung Cancer with Tracheobronchomegaly -A Case Report of Mounier-Kuhn syndrome- (기관지비대증을 동반한 폐암 - 1례 보고 -)

  • 김주현;김태헌;김영태
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.847-850
    • /
    • 1999
  • Tracheobronchomegaly or Mounier-Kuhn syndrome a is rare disease characterized by marked dilatation of the trachea and main bronchi. It is thought to be due to a congenital anomaly, but is uncertain. It has variable clinical manifestations from causing chronic respiratory infections and bronchiectasis to being asymptomatic for the lifetime. Recently, we experienced a case of Mounier-Kuhn syndrome patient with tracheal diverticulum, who had lung cancer. Our case is reported with literature reviews.

  • PDF

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

The changes of symptom, EKG and hemodynamic in healty firefighters after delivering multiple cycles of cardiopulmonary resuscitation (반복적인 심폐소생술 시행 후 건강한 소방대원에서 나타나는 증상, 심전도 및 혈역학적 변화)

  • Lee, Hyo-Ju;Kim, Ho-Jung;Jung, Eun-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.381-388
    • /
    • 2017
  • The CPR guidelines emphasize the delivery of effective chest compressions but do not address the effects of chest compressions on CPR providers. This study determined the effects of chest compressions on healthy adult firefighters' symptoms, hemodynamics, and electrocardiography after performing multiple cycles of CPR. Healthy adult firefighters were trained in CPR and performed CPR on mannequins. The provider vital signs, electrocardiography, and fatigue scores were determined immediately before CPR, after 5cycles of CPR, and after 10 cycles of CPR. In addition, the presence of clinical symptoms among the providers was determined after CPR; 39 firefighters participated in the study. Their mean age was $35.54{\pm}10.26years$. Many providers developed fatigue, shortness of breath, and dizziness. Significant changes in heart rate (p=0.000), respiratory rate (p=0.010), end-tidal CO2(p=0.000), O2 saturation(p=0.000), and pulse pressure (p=0.000) were observed after both 5 and 10 cycles of CPR. One participant developed sinus dysrhythmia and premature ventricular contractions after 10 cycles of CPR. The delivery of chest compression results in fatigue and hemodynamic alterations in many young healthy adults after performing 5 or 10 cycles of CPR. The CPR guidelines and education should take into consideration the effects of chest compressions on CPR providers.

The Influences of Maintenance Hemodialysis on Sleep Architecture and Sleep Apnea in the Patients with Chronic Renal Failure (만성신부전 환자에서 혈액투석 유지요법이 수면구조 및 수면 무호흡에 미치는 영향)

  • Park, Yong-Geun;Lee, Sang-Haak;Choi, Young-Mee;Ahn, Seok-Joo;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.824-835
    • /
    • 1999
  • Background: Sleep-related breathing disorders are commonly found in patients with chronic renal failure and particularly, sleep apnea may have an influence on the long-term mortality rates in these patients. Maintenance hemodialysis is the mainstay of medical measures for correcting the metabolic derangements of chronic renal failure but it is uncertain whether it may alleviate sleep disorders including sleep apnea. Methods: Forty seven patients on maintenance hemodialysis were surveyed with the sleep questionnaire about their clinical symptoms related to sleep disorders. Among them, 15 patients underwent the polysomnography and their blood levels of urea nitrogen, creatinine, electrolytes and the arterial blood gases in the nights before and following hemodialysis were measured. Results: Forty(85.1%) of the 47 patients complained of the symptoms associated with sleep-wake cycle disturbances, 55.3% experienced snoring and 27.7% reported witnessed apneas. The duration of REM sleep increased significantly in the nights after hemodialysis compared to the nights without hemodialysis(p<0.05) and the percentage of total sleep time comprising NREM sleep decreased significantly in the nights following hemodialysis compared to the nights before hemodialysis(p<0.05). The percentage of total sleep time consisting of the stage 1 and 2 NREM sleep showed the trend for a decrease in the nights after hemodialysis(p=0.051), while the percentage of total sleep time comprising the stage 3 and 4 NREM sleep did not change between nights. The obstructive sleep apnea was more predominant type than the central one in both nights and there were no differences in the apnea index and the apnea-hypopnea index between the nights. The decrease in the blood level of urea nitrogen, creatinine, potassium and phosphorus was observed after hemodialysis(p<0.05), but the differences of parameters measured during polysomnography between the nights did not correlate with the changes of biochemical factors obtained on the two nights. Arterial blood gas analysis showed that pH was significantly greater in the nights after hemodialysis than in the nights before hemodialysis(p<0.05), but there were no correlations between the parameters examined during polysomnography and the parameters of arterial blood gas analysis(p<0.05). Conclusion: These results suggest that chronic renal failure is an important systemic disorder which is strongly associated with sleep disorders. Maintenance hemodialysis, although it is a widely accepted measure to treat chronic renal failure, did not significantly modulate the sleep architecture and the severity of sleep apnea. Thus, taking the patients with chronic renal failure into account, it is advisable to try not only to find a substantial way for correcting metabolic derangements but also to consider the institution of more effective treatments for sleep disorders.

  • PDF

Method Development for the Odor-Active Compound Determination by Gas Chromatography/Flame Ionization Detection/Olfactometry (냄새성분 측정을 위한 기체 크로마토그래피/불꽃이온화 검출/후각 검출법의 개발)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Yang, Hee-Hwa
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.180-190
    • /
    • 2001
  • Oder-active compounds are complex in a sample. These compounds are usually analyzed by GC or GC/MSD while such analytical measurement can quantify specific volatile organic compounds, it has limitations in identifying odor-active compounds. To resolve this problem, GC-Sniffing or GC-Olfactometry method has been attempted. In this study, GC/FID/Olfactometry system was developed. This system can simultaneously sniff and detect GC effluents by traditional GC combined with human olfactory system. The time gap between FID and ODP response was dependent on the kinds and concentrations of chemicals and panels, with more volatile, stronger and shorten breath cycle panel showing narrow time gap. Thus, clear relationship between FID and ODP should be considered to identify the odor-active compounds.

  • PDF