• Title/Summary/Keyword: 호재

Search Result 380, Processing Time 0.023 seconds

Experimental Study for Evaluation of Chloride Ion Diffusion Characteristics of Concrete Mix for Nuclear Power Plant Water Distribution Structures (원전 취배수 구조물 콘크리트 배합의 염소이온 확산특성 평가를 위한 실험적 연구)

  • Lee, Ho-Jae;Seo, Eun-A
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.112-118
    • /
    • 2022
  • In this study, the diffusion characteristics were evaluated using the concrete mix design of nuclear safety-related structures. Among the concrete structures related to nuclear power safety, we selected the composition of intake and drainage structures that are immersed in seawater or located on the tidal platform and evaluated the chloride ion permeation resistance by compressive strength and electrical conductivity and the diffusion characteristics by immersion in salt water. analyzed. Compressive strength was measured on the 1st, 7th, 14th, 28th, 56th, and 91st days until the 91st day, which is the design standard strength of the nuclear power plant concrete structure, and chloride ion permeation resistance was evaluated on the 28th and 91st. After immersing the 28-day concrete specimens in salt water for 28 days, the diffusion coefficient was derived by collecting samples at different depths and analyzing the amount of chloride. As a result, it was found that after 28 days, the long-term strength enhancement effect of the nuclear power plant concrete mix with 20% fly ash replacement was higher than that of concrete using 100% ordinary Portland cement. It was also found that the nuclear power plant concrete mix has higher chloride ion permeation resistance, lower diffusion coefficient, and higher resistance to salt damage than the concrete mix using 100% ordinary Portland cement.

Evaluation of Fluidity Over Time and Mechanical Properties of Cement-based Composite Materials for 3D Printing (3D 프린팅용 시멘트계 복합재료의 경시변화 및 역학적 특성평가)

  • Seo, Eun-A;Lee, Ho-Jae;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.73-80
    • /
    • 2022
  • This study evaluated changes in fluidity and rheological properties over time for 3D printed composite materials, and evaluated compressive strength and splitting tensile strength properties for laminated and molded specimens. The composite material for 3D printing starts to change rapidly after 30 minutes of extrusion, and the viscosity of the material tends to be maintained up to 90 minutes, but it was confirmed that construction within 60 minutes after mixing is effective. The compressive strength of the laminated test specimen showed equivalent or better performance at all ages compared to the molded test specimen. In the stress-strain curve of the laminated specimen, the initial slope was similar to that of the molded specimen, but the descending slope was on average 1.9 times higher than that of the molded specimen, indicating relatively brittle behavior. The splitting tensile strength of the P-V laminated specimen was about 6% lower than that of the molded specimen. It is judged that this is because the interfacial adhesion force against the vertical load is affected by the pattern direction of the laminated test specimen.

Strength Characteristics of 3D Printed Composite Materials According to Lamination Patterns (적층 패턴에 따른 3D 프린팅 복합재료의 강도특성)

  • Seo, Eun-A;Lee, Ho-Jae;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.193-198
    • /
    • 2021
  • In this study, the rheological characteristics and of 3D printing composite materials and the compressive strength characteristics according to the lamination patterns were evaluated. As a result of rheology test, rapid material change was observed after 60 minutes of extrusion, yielding stress 1.4 times higher than immediately after mixing, and plastic viscosity was 14.94-25.62% lower. The compressive strength of the specimens manufactured in the mold and the laminated specimens were compared, and the lamination pattern of the laminated specimens were 0°, 45°, and 90° as variables. The compressive strength of the mold casting specimen and the laminated specimen from 1 to 28 days of age showed similar performance regardless of the lamination pattern. In particular, at the age of 28 days, the modulus of elasticity, maximum compressive strength, and strain at maximum stress of all specimens were almost the same. In order to analyze the interface of the laminated specimens, X-ray CT analysis of the specimen whose compressive strength were measured was performed. Through CT analysis, it was confirmed that cracks did not occur at the lamination interface, which can be judged that the interface in the laminated specimen behaved in an integrated manner.

Accounting Conservatism of Public Firm of KONEX (KONEX 상장기업의 회계 보수성에 관한 연구)

  • Jeong, Jong-gu
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.341-348
    • /
    • 2022
  • This study analyzed the accounting conservatism of companies listed on KONEX. The analysis of the existing accounting conservatism presents the analysis results for the KOSPI market or the KOSDAQ market. However, in July 2013, Korea opened a new publicly traded market called KONEX, which has been continuously operated to increase the possibility of SMEs' financing. However, research on KONEX has not been conducted relatively actively, and the current prior research is also focused on earnings management. This study differs from previous studies in that it analyzes accounting conservatism, which is one of the accounting policies. For this purpose, the period from 2014 to 2020 was set as the analysis period, and empirical analysis was conducted using the asymmetric timeliness models, Ball and Shivakumar (2005) and Basu (1997). As a result of the analysis, conditional conservatism was also confirmed in the KONEX market. That is, it was confirmed that the timeliness of the bad news was higher than the good news. Second, no significant difference was found in the results of analyzing whether there is a difference in the conservatism of KONEX companies according to the size of the auditor. In other words, it was confirmed that the size of the auditor in the KONEX market is not a significant variable. This study expanded the existing research in that it analyzed accounting policies targeting the KONEX market.

Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor (봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정)

  • Kim, Byung-Kook;Lee, Ho-Jae;Kim, Go-Tak;Dan, Jinmyoung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.574-578
    • /
    • 2019
  • For the treatment of a bony Bankart lesion accompanied by an acute traumatic shoulder dislocation, anatomical reduction and stable fixation of the bone fragment and glenohumeral ligament are essential to avoid chronic instability or degenerative changes. If the Bankart lesion has large bony pieces or comminuted fragments, it can be difficult to perform precise and secure fixation of the big intraarticular fragment to the fracture site because of the limited visualization of the arthroscopic procedure. In addition, in the case of the open procedure, it requires an extensive surgical dissection to access the fractured fragment, which may cause surgical approach-related morbidity, such as neurovascular complications, delayed subscapularis healing, and increased risk of stiffness. This paper describes an alternative open suture anchor technique for a large bony Bankart lesion, which was secured anatomically with squared knots after a shuttle relay through bony tunnels and adjacent soft tissue and labrum. This technique can achieve anatomical and firm fixation under direct vision, and reduce the number of surgery related morbidities.

Analysis of the factors of the failure of the North Korean Army's Great Bypass Maneuver to Honam during the Korea War from an indirect approach strategy: Focusing on the Naval and Marine Corps' Tongyeong Amphibious Operation to Stop the "Dislocation" (간접접근전략으로 본 6·25전쟁기 북한군의 호남 방면 대우회기동 실패 요인 분석 -'교란'을 저지한 해군·해병대의 통영상륙작전을 중심으로-)

  • Choi, Ho-jae
    • Maritime Security
    • /
    • v.6 no.1
    • /
    • pp.109-135
    • /
    • 2023
  • The North Korean military's maneuver toward Honam was the fastest maneuver the North Korean army had demonstrated during the Korean War, and it was a threatening attack that forced the Korean and Allied forces to fully adjust the defenses of the Nakdong River. However, when this study analyzed the North Korean military's maneuver toward Honam in terms of indirect approach strategy, there were a number of factors that inevitably led to its failure. In terms of implementing the indirect approach strategy, the North Korean military cited a number of failure factors, including the dispersion of combat forces, the inflexibility of changing the line of operation, the maneuvering of ground forces, and the lack of psychological distaction. However, the North Koreans were preparing for a final "surprise attack," in which the 7th Division, which was following the North Korean 6th Division, took another diversion and attempted to attack in the direction of Tongyeong. With this, the North Koreans intended to break through the Nakdong River defenses and head for Pusan. However, the North Korean attack was ultimately thwarted by the Korean Navy and Marine Corps' Tongyeong Amphibious Operation. With a swift maneuver using the sea as a maneuvering space, the Navy and Marine Corps occupied key points first, creating an advantageous situation and fending off an attack by the North Korean 7th Division. The Navy and Marine Corps' Tongyeong Amphibious Operation finally thwarted the North Korean military's maneuver toward Honam, thus maintaining the Nakdong River defenses.

  • PDF

Analysis of Permeability Characteristics for Fly Ash Concrete According to Aggregate Size and Mixing Ratio (골재크기와 배합비에 따른 플라이애시 콘크리트의 투기특성 분석)

  • Eun-A Seo;Do-Gyeum Kim;Chul-Woo Jung;Ho-Jae Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.400-406
    • /
    • 2023
  • In this study, the relationship between the material properties and air permeability characteristics was examined, an experimental method to analyze the air permeability characteristics was presented, and experimental results were derived. The effects of compressive strength and apparent density of hardened concrete on air permeability characteristics were evaluated experimentally. Focusing on the mix proportions used in nuclear power plant concrete structures, concrete test specimens were manufactured and air permeability characteristics were measured according to changes in binder, maximum aggregate size, and water-binder ratio. The apparent density was over 2,400 kg/m3 for the OPC mix and the FA-35 mix, and the air permeability for both mixes were low, in the range of 0.1-0.2 L/min. On the other hand, in the case of the combination of FA-40, FA-45, and FA-M, the apparent density was measured to be less than 2,400 kg/m3 and the air permeability was measured to be more than 0.3 L/min, experimentally verifying that the apparent density is an important factor in air permeability characteristics.

Analysis of Buildability and Strength Characteristics of Cement-based Composite Materials by Manufacturing Method of Laminated Specimens (적층시험체 제작 방식에 따른 시멘트계 복합재료의 적층성능 및 강도 특성 분석)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.9-15
    • /
    • 2023
  • In this study, the lamination performance and strength characteristics of cement-based composite materials according to the laminated specimens manufacturing method were analyzed. As a result of evaluating the buildability according to the layer height, the highest dimensional stability was shown when the layer height was 10 mm in all parts. The mold casting specimen and the printing-Z specimen showed the same compressive strength performance at the age of 28 days. On the other hand, the compressive strength at 28 day of printing-X specimen was the lowest at 71.72 MPa, and 8% lower than that of the mold casting specimen and the printing-Z specimen. The split tensile strength of the laminated specimen may show similar performance to that of the mold casting specimen, but the strength performance may decrease by more than 10% depending on the direction of the layer and the number of layers in the specimen. As a result of the interface analysis of the laminated specimen through X-ray CT analysis, it was confirmed that pores of a certain size were distributed along the interface of the layer.

The Buildability and Strength Properties of 3D Printed Concrete in the Air and Underwater Environment (수중과 기중환경에서 출력된 3D 프린팅 콘크리트의 적층성능 및 강도 특성 분석)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.35-42
    • /
    • 2024
  • This study evaluated the buildability and mechanical properties of 3DP concrete printed in air and underwater environments. Buildability was evaluated by green strength test on fresh concrete and height and deflection immediately and 1 hour after printing. The green compressive strength of the concrete was 5.0 kPa after 30 minutes and 7.9 kPa after 3 hours, an increase of 1.6 times the initial strength. The total height of the laminated parts met the design height regardless of the printing environment. The amount of deflection in air and under water 1 hour after printing was 1 mm and 0.2 mm, respectively, indicating a small amount of deflection under water. The apparent density of the sample appeared in the order of A-M > A-P > UW-P. This is believed to be because a large amount of air is mixed into the concrete during the printing process, and water infiltrates during the underwater printing process. The compressive strength ratio of UW-P/A-P was 0.86 at 1 day, but the compressive strength of the underwater printed concrete was high from 7 days.

Relationship Between Vaginal Cytology and Reproductive Hormone During the Estrous Cycle in Korea Jin-do Bitches (진돗개에서 발정주기 동안 질세포상과 번식호르몬의 관계)

  • 손창호;김정훈;정경아;강현구;오기석;박인철;박상국;한호재
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.225-233
    • /
    • 2000
  • The aim in this study was to obtain the basic data for estimation of optimal mating time and ovulation time by finding out the relationship between vaginal cytology and reproductive hormone profiles during the estrous cycle in 36 Korea Jin-do bitches. A characteristic features of vaginal cytology during the estorous cycle were the high proportion of superficial cell, anuclear cell and erythrocyte in proestrus, superficial cell, anuclear cell and erythroucyte in estrus, parabasal cell, small and large intermediate cell and leukocytes in diestrus, and parabasal cell and small intermediate cell in anestrus, respectively. Cornification index(CI) was the high proportion in proestrus and estrus, then it was decreaed in diestrus and anestrus. It indicated that the CI was significantly high proportion in proestrus and estrus in comparison with the other phases. Plasma progesterone concentration was below 1.0ng/ml at the first day of vulval bleeding in pregnant and non-pregnat bitches, and then it was increaed slowly. When Day 0 was timed from the day that plasma progesterone concentration was first increased above 4.0ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant above 4.0 ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant bitches were $5.2{\pm}0.3ng/ml and 5.7{\pm}0.5ng/ml$$46.5{\pm}3.3 ng/ml$ in pregnant bitches and at Day 20 with $39.8{\pm}0.1ng/ml$ in nonpregnant bitches. It indicated that plasma progesterone concentration was higher in pregnant bitches than in non-pregnant bitches. Hereafter plasma progesterone concentration was decreased steadily. At Day 63 which is parturition day, plasma progesterone concentration was decreased below 1.0ng/ml with $0.8{\pm}0.2ng/ml$ in pregnant bitches whereas in the non-pregnant bitches at Day 75 were decreased below 1.0ng/ml with 40.5{\pm}0.4ng/ml$. Plasma progesterone concentrations was maintained below 1.0ng/ml during anestrus in all of them. The plasma estradiol-17 $\beta$ concentration was increased above 1.0 pg/ml at the first day of vulval bleeding and it showed a peak Day-1 with 38.2 pg/ml. Thereafter it was sharply decreased after Day 0, which was the day that plasma progesterone concentration was first increase above 4.0ng/ml, and was maintained below basal levels. In relationship between CI and reproductive hormones, plasma estradiol-17 $\beta$concentration showed a peak at Day-3 and CI showed a peak at Day-1 which was the second day after plasma estradiol-17 $\beta$ peak, and plasma progesterone concentration was first increased above 4.0ng/ml at Day 0 which was the first day after CI peak. CI was first increased above 80% at Day-6 which was the third day before plasma estradio-17 $\beta$ peak and it was maintained above 80% between Days-6 and Day 3 during 10 days, and showed above 90% at Day-3 which was the day that plasma estradiol-17 $\beta$peak and was maintained above 90% between Day-3 and Day 3 during 7 days. In conclusion, ovulation in Koran Jin-do bitches occurred at the first day after CI peak, at the third day after plasma estradiol-17 $\beta$peak and the day when plasma progesterone concentration was first increased above 4.0 ng/ml. And it was estimated that the optimal mating time was the day when the CI was maintained above 90% and plasma progesterone concentration was between 3.0~8.0ng/ml. Therefore plasma progesterone concentration measurement was used for determination of an accurate ovulation time and the optimal mating time but also vaginal cytology, which is low-priced with equipment and is the simple examination method, was reliable method for estimating estrous cycle, optimal breeding time and ovulation time in Korea Jin-do bitches.

  • PDF