• Title/Summary/Keyword: 형광분석

Search Result 1,192, Processing Time 0.039 seconds

Uranium Fluorescence Analysis in the Raffinate Solution of Nuclear Fuel Conversion Process Using Time-resolved Laser-induced Fluorimetry (레이저 유발형광법을 이용한 변환공정 폐액중의 우라늄 형광분석)

  • Lee, Sang-Mock;Kim, Duk-Hyeon;Shin, Jang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.548-551
    • /
    • 1993
  • A simple and new uranium analysis technique for raffinate solution of nuclear fuel conversion process was developed using a time-resolved laser-induced fluorimetry. The addition of 4 M-phosphoric acid more than 10 times in volume to the raffinate sample was found to be efficient for obtaining stable uranium fluorescence signal which was not influenced by many fluorescence quenchers. A calibration curve of a good linearity for the fluorescence intensity vs. the uranium concentration was obtained at the range of 3.0$\times$10$^{-6}$-6.0$\times$10$^{-5}$ M U $O_2$$^{2+}$ in the raffinate samples.

  • PDF

Fluorescence Signal Analysis of Mixed Rare Earth Elements by Nonlinear Fitting Method (비선형 Fitting법에 의한 희토류 혼합물의 형광신호 분석)

  • Kim, Dukhyeon;Shin, Jangsoo;Song, Kyuseok;Cha, Hyungki;Lee, Jongmin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.41-45
    • /
    • 1995
  • To analyze mixed rare earth elements quantitatively a nonlinear fitting method was applied to laser induced fluorescence signals. Mixed flourescence signal of two elements, Sm and Eu were resolved independently and determined the concentration of these two elements simultaneously. It was found that detection limit for each element in the mixture was sub-ppb level which was the same as that of the single element sample. Additionally it was found that lifetimes of Sm and Eu extracted from the nonlinear fitting method is the same as in the single element cases.

  • PDF

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

나트륨 Flux 혼합첨가에 따른 MgWO4:Tb3+ 형광체의 합성과 발광 특성

  • Gang, Dong-Gyun;Lee, Seong-Jae;Jo, Seon-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.221-221
    • /
    • 2016
  • 최근에 희토류 이온이 도핑된 텅스텐산(tungstates) 형광체에 대한 연구가 재조명되고 있다. 텅스텐산 형광체는 우수한 광학적 특성과 높은 화학적 안정성을 나타내기 때문에 X-선 증강 스크린(X-ray intensifying screens), 광고판용 형광 램프, 발광 다이오드, 레이저, 섬광체(scintillator), 전계방출 디스플레이 영역에 그 응용성을 넓히고 있다. 본 연구는 모체 결정 MgWO4에 희토류 이온인 Tb3+와 융제(flux)의 몰 비를 변화 시켜 고상반응법을 사용하여 합성을 하였다. 합성한 형광체를 여기 파장 281 nm로 제어하였을 시, 545 nm의 녹색 발광 스펙트럼을 관찰 하였다. Tb3+이온이 0.10 mol일 때, 가장 발광 세기가 컸으며, 몰비가 증가 할수록 발광의 세기는 점차 커지다가 0.12 mol에서 작아졌다. 주 발광 신호 이외에도 489 nm, 586 nm, 621 nm에서 상대적으로 작은 발광 스펙트럼을 보였다. XRD를 통해 분석한 결정구조는 단사정계임을 알 수 있었으며 주 피크는 $23.9^{\circ}$에서 발생 하였고 이는 (110)면에서 발생한 회절 신호이다.

  • PDF

Performance Evaluation and Analysis of Fluorescent Parallel Lamp Electronic Ballast System (FPL용 전자식 안정기 시스템의 성능평가 및 분석)

  • Kim, Sun-Gi;Kim, Yeong-Su;Hong, Seok-Jeong;Kim, Eung-Rae;Lee, Jang-Won;Min, Dae-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.101-105
    • /
    • 2005
  • 형광램프의 절전화에 있어서 기본적으로 고려해야 할 점은 램프측의 절전은 램프전력을 감소시키고, 안정기측의 절전은 램프전류를 감소시킴으로써 이루어진다. 형광램프의 절전화에 있어 핵심요소는 봉입기체의 변경, 관경의 세관화 그리고 형광체의 개량에 있다. 즉, 램프 전력을 절감하기 위해 최적의 봉입기체를 선택하도록 하고, 램프전류를 억제하기 위해 관경을 줄이는 한편, 관경의 축소에 따른 형광체의 열화를 막기 위해 3파장 형광체와 같은 새로운 형광체를 사용해야 한다. 본 논문에서는 FPL36W에 대해 전기적 특성시험과 안정기수명시험 및 램프수명말기시험, 저온에서의 온 오프 시험 등을 실시하여 전자식 안정기 성능을 향상시키는 방안을 모색하였다.

  • PDF

무기물 형광체를 사용한 고효율 순백색 유기발광소자의 전기적 성질과 광학적 성질

  • An, Seong-Dae;Jeong, Hwan-Seok;Chu, Dong-Cheol;Kim, Tae-Hwan;Lee, Jun-Yeop;Park, Jeong-Hyeon;Gwon, Myeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.427-427
    • /
    • 2010
  • 전색 디스플레이의 배경조명과 일반조명으로 응용 가능한 백색 유기발광소자를 제작하기 위해서는 삼원색을 혼합하는 방법과 단색광원의 색변환을 이용하는 방법등이 제안되었다. 삼원색을 혼합하는 방법의 연구가 접근방법 및 효율개선이 용이하기 때문에 많은 연구가 진행되어왔다. 그러나 색변환 방법을 사용하는 구조는 삼원색을 혼합하는 방법에 비해 공정이 단순하며 공정 가격이 낮아지고 안정적인 구조라는 장점이 있기에, 본 연구에서는 무기물 형광체를 청색유기발광 소자에 결합하여 제작된 백색 유기발광소자의 전기적 성질과 광학적 성질을 규명하는 연구를 진행하였다. 본 연구에서는 나노크기의 균일한 형광체를 제작 할 수 있는 졸겔 방법으로 적색 형광체를 제작하였다. 졸겔 방법으로 제작된 형광체에 대한 주사현미경 측정 결과 입자의 표면이 고르며 크기가 작고 균일 하였고, 높은 온도 열처리에 따라서 용매제가 대부분 제거되었기 때문에 형광체 발광 특성이 잘 일어났음을 확인 할 수 있었다. 제작된 형광체의 광학적 성질을 조사하기 위해 형광 루미네센스 측정을 하여 발광특성을 분석하였으며 실제 청색 유기발광소자에 적용하기 위해 tris((3,5-difluoro-4-cyanophenyl)pyridine)iridium (FCNIr)-doped 3,5-bis (N-carbazolyl) benzene (mCP)를 발광층으로 사용하는 진청색의 인광 유기발광소자 배면에 무기물 형광체를 결합하여 인가한 전압에 따른 전계발광분광특성의 변화를 조사하였다. 유기발광소자와 결합된 적색 무기물 형광체는 진청색 인광 유기발광소자에서 발광된 청색빛의 일부를 흡수하여 적색으로 색변환을 하였고 이는 무기물 형광체내에 첨가된 Mn 원자에 의해 색변환이 이루어졌음을 확인하였다. 무기물 형광체를 사용한 백색 유기발광소자의 색변환 메카니즘 및 효율 증진에 대한 연구는 고효율 유기발광소자 제작을 가능하게 할 것이다.

  • PDF

Laboratory-scale fluorescence spectroscopic method using UV for monitoring soils contaminated with petroleum produce (자외선 형광 분석법을 이용한 유류 토양오염 모니터링 시스템의 현장 적용을 위한 기초 연구)

  • 김우진;박재우;이주인
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.48-58
    • /
    • 2002
  • As a pilot experiment for developing the monitoring system for oil spill from storage tank, previous approach of monitoring contaminated oil from mixed soil sample had the limitation that it cannot reflect the real situations of the contamination. In this study, more realistic contamination condition and water contents were considered. Fluorescence intensity was not affected by water contents. To acquire the stability of media, sand, Ca-bentonite, alumina, Fe-oxide, bead and silica were tested. Only sand was suitable to our system. These results should provide basic information for constructing reliable monitoring system.

Nondestructive Analysis of Textile Dyed with Traditional Blue and Green (전통 청색 및 녹색 염료로 염색한 직물의 비파괴 분석)

  • Yun, Eunyoung;Kwon, Hyeyoung
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.81-89
    • /
    • 2013
  • This study concerns UV-Vis spectrophotometry and 3D-fluorescence spectrophotometry analysis of textile parts of blue and green tones dyed with indigo of blue tone and turmeric, gardenia, goldthread and amur cork tree of yellow tone. In order to verify whether the kinds of textiles affected analysis result of each dye, silk and cotton textile samples were produced. According to the analysis of the degree of reflection of UV-Vis spectrophotometry, unique reflection spectrum of indigo appeared regardless of the kinds of textiles when they were dyed with indigo. As for textiles of green tone, the 3D-fluorescence spectroscopic analysis result showed that unique spectrums of yellow dyes, turmeric, goldthread and amur cork tree appeared regardless of the kinds of textiles but the fluorescence spectrums of gardenia and indigo did not appear.

DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증의 진단)

  • Seol, Jae-Heon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.236-246
    • /
    • 2004
  • Artificial carious lesions in various depths were observed with visual examination using light transillumination, bite-wing radiography, laser fluorescence, and dye-enhanced laser fluorescence to determine the reproducibility, correlation of each diagnostic method, diagnostic sensitivity and diagnostic specificity. And optical densities according to demineralized times were measured whether laser fluorescence could be used as a quantitative diagnostic method. The following results were obtained whether laser fluorescence could be used for diagnosis of initial proximal caries. 1. Tau-c values of visual examination was 0.08 which showed lowest reproducibility and those of bite-wing radiography, laser fluorescence, dye-enhanced laser fluorescence were 0.60, 0.48, and 0.64, respectively which showed relatively high reproducibility. 2. The correlation between demineralization time and each examination was the highest in dye-enhanced laser fluorescence$({\gamma}=0.51)$ followed by laser fluorescence$({\gamma}=0.43)$, bite-wing radiograph$({\gamma}=0.35)$, and visual examination$({\gamma}=0.33)$. Dye-enhanced laser fluorescence and laser fluorescence showed significant correlation with demineralization time. 3. The sensitivity of laser fluorescence and dye-enhanced laser fluorescence for diagnosing approximal caries based on bite-wing radiography were 67%, 100% and those of specificity were 57%, 11% which showed diagnostic specificity was relatively lower than sensitivity. 4. The difference in optical density(DFR) between sound teeth and carious lesions according to lesion depth was high with dye-enhanced laser fluorescence compared with laser fluorescence. DFR measured with laser fluorescence according to changes in lesion depth was statistically significant but was not statistically significant with dye-enhanced laser fluorescence. Based on these results, laser fluorescence and dye-enhanced laser fluorescence have comparable diagnostic power as bite-wing radiography in early diagnosis of proximal caries.

  • PDF

Synthesis and Characteristic Evaluation of Downward Conversion Phosphor for Improving Solar Cell Performance (태양전지 성능향상을 위한 하향변환 형광체의 합성 및 특성평가)

  • Jae-Ho Kim;Ga-Ram Kim;Jin-To Choi;Soo-Jong Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.523-528
    • /
    • 2023
  • The applicability as a material to improve solar cell performance was reviewed by synthesizing a phosphor that emits red wavelengths by a liquid synthesis method using a metal salt aqueous solution and a polymer medium as a starting material. An aqueous solution was prepared using nitrate of metals such as Ca, Zn, Al, and Eu, and a precursor impregnated with starch, a natural polymer, was sintered to synthesize CaZnAlO:Eu phosphor powder. The surface structure and composition analysis of the synthesized CaZnAlO:Eu phosphor powder were analyzed by scanning electron microscope(SEM) and energy-dispersed X-ray spectroscopy(EDS). The crystal structure of CaZnAlO:Eu phosphor particles was analyzed by an X-ray diffraction analyzer (XRD). As a result of measuring the photoluminescence(PL) characteristics of the phosphor, it was confirmed that a red phosphor with a light emitting wavelength of 650-780nm was successfully synthesized. According to SEM and EDS analysis, the synthesized Ca14Zn6Al9.93O35:Eu3+0.07 phosphor powder has a uniform particle size, and Eu ions used as an activator are present. The synthesized CZA:Eu3+ phosphor can be used as a material that can increase the light absorption efficiency of the solar cell by converting ultraviolet or visible light down conversion into a wavelength in the near-infrared region.