• Title/Summary/Keyword: 형광분석법

Search Result 417, Processing Time 0.032 seconds

Fluorescence Signal Analysis of Mixed Rare Earth Elements by Nonlinear Fitting Method (비선형 Fitting법에 의한 희토류 혼합물의 형광신호 분석)

  • Kim, Dukhyeon;Shin, Jangsoo;Song, Kyuseok;Cha, Hyungki;Lee, Jongmin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.41-45
    • /
    • 1995
  • To analyze mixed rare earth elements quantitatively a nonlinear fitting method was applied to laser induced fluorescence signals. Mixed flourescence signal of two elements, Sm and Eu were resolved independently and determined the concentration of these two elements simultaneously. It was found that detection limit for each element in the mixture was sub-ppb level which was the same as that of the single element sample. Additionally it was found that lifetimes of Sm and Eu extracted from the nonlinear fitting method is the same as in the single element cases.

  • PDF

Enumeration of Weissella cibaria phage with cytometry, epifluorescence microscopy, and plaque assay (유세포분석기, 형광현미경, 용균반검사 분석을 이용한 Weissella cibaria 박테리오파지 정량분석 및 상관관계분석)

  • Park, Won Jeong;Lim, Ga-Yeon;Park, Jong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.244-247
    • /
    • 2018
  • Quantitative analysis for non-host infection bacteriophage was conducted for their enumeration. Flow cytometry and epifluorescence microscopy (EPM) were selected as counting methods. Correlation analysis was performed based on the plaque assay method on the existing host infection and consisted of Pearson correlation statistical analysis, regression analysis, and difference analysis. Analyses of 12 samples with flow cytometry and plaque assay methods showed that there was a correlation of 96.7% with Pearson correlation value r=0.967, $R^2$ 0.9352, and difference value of 1.063. Analyses of 12 samples with EPM and plaque assay methods showed that there was a correlation of 99.0% with Pearson correlation value r=0.990, $R^2$ 0.9811, and difference value of 1.605. Therefore, flow cytometry and epifluorescence microscopy would be effective for enumeration of Weissella cibaria bacteriophage with plaque assay.

A Study on the Development of Quantitative Analysis Methods to Characterize the Transport of Microplastics in Saturated Porous Media (포화 다공성 매체에서 미세플라스틱 이동 특성 규명을 위한 정량분석 방법 개발 연구)

  • Suhyeon Park;Minjune Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.376-376
    • /
    • 2023
  • 전 세계적으로 중요한 담수 자원인 지하수의 미세플라스틱 오염에 대한 우려가 커지고 있다. 지하수 환경에서 미세플라스틱의 오염을 예측하고 평가하기 위해 대수층 내 현장 실태조사가 수행 중에 있으며, 실험실 규모의 컬럼 실험을 통해 지하수에서 미세플라스틱 이동 메커니즘을 조사하는 연구들이 수행되고 있다. 이러한 연구들은 많은 개수의 분석 시료를 동반하며, 환경 중 미세플라스틱 정량분석을 위해서 고가의 분석기기(라만분광기, 푸리에 변환 적외선(FTIR) 분광기, 열분해 가스크로마토그래피 질량분석기)를 사용하여 플라스틱의 종류를 판별하고 개수를 측정하고 있다. 또한, 컬럼 실험을 수행한 대부분의 선행 연구에서는 미세플라스틱 정량분석을 위해 탁도 분석, 분광광도계를 이용한 흡광도 분석, 현미경을 이용한 계수 방법 등을 이용하여 고가의 분석기기를 사용하지 않고 연구를 수행하였다. 하지만, 이러한 방법들은 유체 속 다른 물질이 포함되어있을 경우에 민감하고 농도를 비율 혹은 개수로 표현하기 때문에 질량 측면에서 미세플라스틱의 농도를 과소·과대 평가할 수 있다. 특히, 현미경을 이용한 계수 방법의 경우에는 분석에 많은 시간이 소요된다는 단점이 있다. 위에 언급한 다양한 분석법들의 단점들을 보완하기 위하여, 본 연구에서는 대수층 내 미세플라스틱 이동 특성을 규명하기 위한 실내 실험에 사용될 수 있는 형광이미지 기반의 미세플라스틱 정량분석법을 개발하였다. Nile Red 형광염료를 이용하여 미세플라스틱을 염색하고 사진을 촬영하여 미세플라스틱 시료의 질량과 미세플라스틱 형광이미지의 형광강도 간 상관관계를 분석하였다. 또한, Nile Red로 염색된 미세플라스틱 입자의 수중 노출 테스트를 진행하여, 실내 대수층 모의실험 시 미세플라스틱 질량을 정량화할 수 있는 적용 가능성을 평가하였다. 상관 분석 결과, 미세플라스틱 질량과 이미지의 형광강도는 높은 상관관계를 보였으며, 수중 노출 실험 전과 후의 미세플라스틱 입자의 형광강도 차이는 미미한 것으로 나타났다. 이러한 연구결과를 통해 본 연구에서 개발된 미세플라스틱 정량분석 방법이 포화 다공성 매체로 구성된 컬럼실험 시 유출수의 미세플라스틱 질량 추정에 유용하게 사용될 것으로 생각되며, 대수층 내 미세플라스틱의 이동 특성 규명 연구에 많은 도움이 될 것으로 기대된다.

  • PDF

나트륨 Flux 혼합첨가에 따른 MgWO4:Tb3+ 형광체의 합성과 발광 특성

  • Gang, Dong-Gyun;Lee, Seong-Jae;Jo, Seon-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.221-221
    • /
    • 2016
  • 최근에 희토류 이온이 도핑된 텅스텐산(tungstates) 형광체에 대한 연구가 재조명되고 있다. 텅스텐산 형광체는 우수한 광학적 특성과 높은 화학적 안정성을 나타내기 때문에 X-선 증강 스크린(X-ray intensifying screens), 광고판용 형광 램프, 발광 다이오드, 레이저, 섬광체(scintillator), 전계방출 디스플레이 영역에 그 응용성을 넓히고 있다. 본 연구는 모체 결정 MgWO4에 희토류 이온인 Tb3+와 융제(flux)의 몰 비를 변화 시켜 고상반응법을 사용하여 합성을 하였다. 합성한 형광체를 여기 파장 281 nm로 제어하였을 시, 545 nm의 녹색 발광 스펙트럼을 관찰 하였다. Tb3+이온이 0.10 mol일 때, 가장 발광 세기가 컸으며, 몰비가 증가 할수록 발광의 세기는 점차 커지다가 0.12 mol에서 작아졌다. 주 발광 신호 이외에도 489 nm, 586 nm, 621 nm에서 상대적으로 작은 발광 스펙트럼을 보였다. XRD를 통해 분석한 결정구조는 단사정계임을 알 수 있었으며 주 피크는 $23.9^{\circ}$에서 발생 하였고 이는 (110)면에서 발생한 회절 신호이다.

  • PDF

Development and comparison of convenient residue analysis for avermectin B1 in apple and soil (사과 및 토양중 avermectin B1의 간편한 잔류 분석법 개발과 비교)

  • Lee, Kang-Bong;Kim, Yong-Du;Shim, Jae-Han;Suh, Yong-Tack
    • Applied Biological Chemistry
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 1992
  • Avermectin B1(abamectin) is an very effective acaricide/insecticide. Because it is applied at low rates, the resultant residue level would be quite low and this requires highly sensitive analytical method. In this study, three analytical methods for avermectin $B1_a$, were compared in view of detectability and sensitivity. The first analytical method was an HPLC method employing the fluorescence detection of avermectin. The second analytical technique to quantitate avermectin $B1_a$, and its photodegradative delta 8,9-isomer employed trifluoroacetic anhydride and 1-methylimidazole in DMF. The new method was the modification of trifluorescence method. The average recoveries of avermectin $B1_a$ for the concentration range from 1 and 10 ng/g in whole apple fruit by fluorescence method were 90.3% and 88.2% respectively. In trifluorescence method, the recoveries of the avermectin $B1_a$ and delta 8,9-isomer were 100.7% and 94.7% in concentration from 5 ng/g and 25 ng/g. The average recoveries of 5 ng and 25 ng/g in the newly modified method were 95.0, 99.0. 96.0, 92.8% in whole apple and soil respectively.

  • PDF

Properties of Powder and Fluorescence as a Function of Oxygen Partial Pressure in ZnO : Zn System Prepared by Glycine Nitrate Process (GNP 방식으로 제초한 ZnO : Zn의 산소분압에 따른 분말특성 및 형광특성)

  • Choi, Woo-Sung;Park, Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.378-382
    • /
    • 1999
  • 저 전압용 형광체는 최근에 활발히 연구가 진행되고 있으며 가장 대표적인 형광체가 ZnO Zn 녹색 형광체이다. ZnO : Zn 형광체는 자체발광형 형광체로써 ZnO을 환원분위기 하에서 열처리를 함으로써 얻을 수 있다. 본 연구에서는 자발착화 연소반응법(Glycine Nitrate Process)을 이용하여 ZnO : Zn 분말을 합성하고 형광특성 및 분말특성을 알아보았다. 출발물질로는 Zn Nitrate와 Glycine을 이용하였고 자발연소 반웅이 발생하는데 적절한 글리신의 양을 확인하기 위해서 글리신과 양이온의 비를 변화시키며 ZnO를 합성하였다. 그리고 Zn Excess가 생겨난 앙과 그에 따른 형광특성을 관찰하기 위해 $N_2$ 분위기 에서 각기 50$0^{\circ}C$, 75$0^{\circ}C$, 95$0^{\circ}C$의 온도에서 열처리를 행하였다. 제조된 ZnO 분말의 입자형태와 결정상 태는 SEM과 XRD를 이용하여 분석하였고 TG-DTA를 측정하여 열처리온도에 따른 질량감소(Zn excess)를 관찰하였다. 또 Particle size analyzer로 분말의 크기를 알아보았고 형광체로써의 발광특성을 살펴보기 위해 PL을 이용하여 발광피크를 관찰하였다.

  • PDF

Studies on Membrane Fouling Monitoring by Fluorescence Nano Particle and Fluorescent Spectrometry (형광 나노 입자 및 형광 분광 분석을 이용한 막오염 측정법 연구)

  • Seo, Mi-Rae;Nam, Mi-Yeon;Kim, Beom-Sik;Nam, Seung-Eun;Kim, In-Chul;Park, You-In
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.163-170
    • /
    • 2011
  • Membrane fouling control in water treatment may be the main obstacle for wider implementation and lower cost. A novel fluorescent spectroscope sensor device for membrane fouling integrity monitoring has been developed and evaluated in this study. PSf membranes for water treatment has been fabricated with three types of organic fluorescent materials, OB, FP, KCB. The fluorescent signal from membrane surface was analyzed throughout the filtration process. It was found that the fluorescent signal due to the membrane fouling decreased and the developed device is reliable for membrane fouling monitoring.

The Optical Property of nano-sized $Gd_2O_3:Eu^{3+}$ Phosphor using solution method (액상반응법으로 합성한 $Gd_2O_3:Eu^{3+}$ 나노형광체의 열처리 온도에 따른 광학적 특성)

  • Park, Chung-Sik;Kwak, Min-Ki;Yoon, Seung-Pil;Hong, Sung-Jei;Han, Jeong-In;Song, Yo-Seung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.157-159
    • /
    • 2005
  • 본 연구에서는 저온 액상반응법을 이용하여 활성제 Eu의 농도를 10wt%로 도핑하고 열처리를 각각 450, 700, $900^{\circ}C$로 1h 유지하여 $Gd_2O_3:Eu^{3+}$ 나노형광체를 합성하였다. 제조된 형광체의 결정화, 입자크기를 XRD, BET로 분석하였고, 이들이 발광 휘도에 미치는 영향을 확인하였다. 또한 합성된 형광체의 PL(photoluminescence) 특성을 알아보기 위해 여기파장 254nm 의한 발광스펙트럼, 611nm에 의한 여기스펙트럼을 조사하였다. 발광 특성은 611nm에서 주 peak을 갖는 $Eu^{3+}$ 이온에 의한 $^5D_0-^7F_{J(J=0,1,2)}$ 전이에 기인된 전형적인 Red 형광체의 특성을 나타냈고, 입자크기는 평균 20-60nm 정도이고, 발광강도는 열처리 온도가 증가함에 따라 향상되었다.

  • PDF

X-Ray Fluorescence Analysis of Iron and Titanium in Iron Ores by Dilution Parameter Method (희석 파라미터법에 의한 철광석 중 철과 티탄의 X-선 형광분석)

  • Young Sang Kim;Lee Chong Wook
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.3
    • /
    • pp.183-189
    • /
    • 1981
  • Iron and titanium, the major constituents in iron ores, were X-ray spectrometrically determined by using the dilution parameter method. A standard and samples possessing a similar composition were diluted with the diluent $ZrO_2$ to their proper respective ratios. After measuring the intensity of the fluorescent X-ray, the dilution parameter was calculated from the following equation. $Pa=\frac{\frac{I_{as}}{(I_{as})_d}}{D-1}{^{-1}}$The dilution parameters were used to correct the difference between the matrix effect of the standard and that of the sample. The content of the major constituents was calculated, without using any standard calibration curves, from the following equation;$W_a=W_a^*{\cdot}{\frac{I_as}{I_{as}^*}{\cdot}\frac{P_a^*}{P_a}$where asterisks indicate the standard. The results agreed with those of the wet analysis within 2% of relative error, and the precision of the experiment was also tolerably good.

  • PDF

액상법으로 제조된 ZnS:Cu계 나노 형광체의 합성 및 광특성 연구

  • Wang, Yeong-Im;Lee, Won-Hui;Lee, Seong-Ui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.180-180
    • /
    • 2009
  • 나노 형광체 합성에 있어서 입자 형상 및 입자 크기의 변화를 알아보기 위해 녹색 발광하는 ZnS:Cu 형광체를 액상반응법으로 합성하였다. X선 회절 분석기로 결정성을 확인하였으며, 전계 방사 주사 전자 현미경 (FE-SEM)을 통해 각각 30~80 nm 이하 크기임을 확인하였다. 녹색발광을 하며, 450 $^{\circ}C$부터 900 $^{\circ}C$ 까지 온도 상승함에 따라 결정성이 증가 하였으며, hexagonal구조에서 가장 효율이 높은 PL 값을 보였다.

  • PDF