• Title/Summary/Keyword: 혈중산소포화도

Search Result 58, Processing Time 0.021 seconds

Effects of Three Levels of Flow Rate of Highly Concentrated Oxygen Administration on SpO2 and HR of 60s Male and Female (세가지 유량의 고농도 산소 공급이 60대 남녀의 혈중 산소 포화도와 심박동률에 미치는 영향)

  • Kim, Ji-Hye;Choi, Mi-Hyun;Lee, Su-Jeong;Yang, Jae-Woong;Jun, Jae-Hoon;Min, Byung-Chan;Lee, Tae-Soo;Chung, Soon-Cheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.853-860
    • /
    • 2010
  • This study investigated differences in blood oxygen saturation($SpO_2$) and heart rate(HR) according to flow rate, gender, and phase in males and females in their 60s when the supply of 93% highly concentrated oxygen administration was changed (1L/min, 3L/min, and 5L/min). It recruited totally 20 elderly subjects including 10 males($68.0{\pm}2.6$ years) and 10 females ($65.5{\pm}3.1$ years). The experiment consisted of three phages of Rest 1(5 min), Hyperoxia(10 min), and Rest 2(10 min), and $SpO_2$[%] and HR[bpm] were measured during all phages. $SpO_2$ was higher in Hyperoxia phase supplied with highly concentrated oxygen than in Rest phases. Higher flow rate was associated with more increase in $SpO_2$. HR was reduced in Hyperoxia phase compared to Rest phases. More supply of highly concentrated oxygen was associated with more decrease of HR. However, there were no differences in both $SpO_2$ and HR according to gender.

The Influence of the Preoperative Chronic Cyanosis on the Cardiac Troponin I in the Pediatric Cardiac Operation (지속적인 청색증에 노출된 선천성 심장병에서 수술 후 Cardiac Troponin I의 농도 변화)

  • Song, Jinyoung;Lee, Sungkyu;Lee, Jaeyoung;Kim, Soojin;Shim, Wooseup
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.498-504
    • /
    • 2002
  • Purpose : The purpose of this study was to evaluate the perioperative myocardial damage in pediatric congenital heart disease with the cardiac specific protein of cardiac troponin I(cTpn-I). Methods : All 25 pediatric patients who were diagnosed with tetralogy of Fallot or double outlet right ventricle were classified as group A(acyanotic, $SaO_2$ >90%), group B(mildly cyanotic, $SaO_2$ >80-90%) and group C(moderately cyanotic, $SaO_2$ <80%). The control group D was consisted of 10 patients with ventricular septal defects who were operated in the same period. We measured preoperative hemoglobin, preoperative and postoperative(24 and 72 hour) arterial oxygen saturation, cTpn-I and creatine kinase(CK-MB). Results : Total 25 patients were subdivided into 6 of group A, 12 of group B and 7 of group C. The concentrations of preoperative cTpn-I were $0.23{\pm}0.12ng/mL$ in group A, $0.25{\pm}00.12 ng/mL$ in group B, $0.26{\pm}0.13ng/mL$ in group C. And the concentrations of cTpn-I in postoperative 24 hour were $10.04{\pm}5.28ng/mL$ in group A, $12.50{\pm}6.86ng/mL$ in group B, $12.55{\pm}9.90ng/mL$ in group C. Which revealed cTpn-I in group C was higher than that of the another less cyanotic groups. In addition, the concentration of cTpn-I of group C in postoperative 72 hour was higher than any other groups. The concentration of cTpn-I in postoperative 72 hour was statistically correlated with that in postoperative 24 hour and preoperative arterial oxygen saturation(P=0.001). Conclusion : Preoperative chronic cyanosis can influence on the postoperative concentration of cTpn-I in pediatric cardiac patients, which means impairment on the postoperative myocardial recovery.

The Changes of Cerebral Metabolic Parameters, Serum Levels of Neuron-Specific Enolase and S-100$\beta$ Protein During Retrograde Cerebral Perfusion Under Profound Hypothermic Total Circulatory Arrest (초저체온하 완전순환정지 시에 이용되는 역행성 뇌관류의 시간에 따른 뇌대사 지표, 혈청 내 neuron-specific enolase, 및 S-100 베타단백의 변화)

  • 김경환
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.653-661
    • /
    • 2001
  • Background: Retrograde cerebral perfusion(RCP) is one of the methods used for brain protection during aortic arch surgery. The author previously published the data, however, for the safety of it, there still remains many controversies. The author performed RCP and checked various parameters to clarify the possibility of early detection of cerebral injury. Material and Method: The author used pigs(Landrace species) weighing 25 to 30kg and performed RCP for 120 minutes. After weaning of cardiopulmonary bypass, we observed pigs for another 120 minutes. Rectal temperature, jugular venous oxygen saturation, central venous pressure were continuously monitored, and the hemodynamic values, histological changes, and serum levels of neuron-specific enolose(NSE) and S100$\beta$ protein were checked. Central venous pressure during RCP was maintained in the range of 20 to 25 mmHg. Result: Flow rates(ml/min) during RCP were 224.3$\pm$87.5(20min), 227.1$\pm$111.0(40min), 221.4$\pm$119.5(60min), 230.0$\pm$136.5(80min), 234.3$\pm$146.1(100min), and 184.3$\pm$50.5(120min). Serum levels of NSE did not increase after retrograde cerebral perfusion. Serum levels of S100$\beta$ protein(ng/ml) were 0.12$\pm$0.07(induction of anesthesia), 0.12$\pm$0.07(soon after CPB), 0.19$\pm$0.12(20min after CPB), 0.25$\pm$0.06(RCP 20min), 0.29$\pm$0.08(RCP 40min), 0.41$\pm$0.05(60min), 0.49$\pm$0.03(RCP 80min), 0.51$\pm$0.10(RCP 100min), 0.46$\pm$0.11(RCP 120min), 0.52$\pm$0.15(CPBoff 60min), 0.62$\pm$0.15(60min after rewarming), 0.76$\pm$0.17(CPBoff 30min), 0.81$\pm$0.20(CPBoff 60min), 0.84$\pm$0.23(CPBoff 90min) and 0.94$\pm$0.33(CPBoff 120min). The levels of S100$\beta$ after RCP were significantly higher than thosebefore RCP(p<0.05). The author could observe the mitochondrial swellings using transmission electron microscopy in neocortex, basal ganglia and hippocampus(CA1 region). Conclusion: The author observed the increase of serum S100$\beta$ after 120 minutes of RCP. The correlation between its level and brain injury is still unclear. The results should be reevaluated with longterm survival model also considering the confounding factors like cardiopulmonary bypass.

  • PDF

Comparison of Daytime Sleepiness between Normal Subjects and Patients with Sleep Disorders and Analysis of Its Clinical Implications (정상인과 수면장애 환자군 간의 주간졸림증 비교 및 임상적 의미 분석)

  • Lee, Jin-Sung;Kim, Seog-Ju;Choi, Jong-Bae;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.2
    • /
    • pp.106-114
    • /
    • 2002
  • Objectives: Daytime sleepiness is a common symptom and is associated with sleep behavior, sleep deprivation, and night shift, etc. It is also one of the most important symptoms of sleep disorders like obstructive sleep apnea (OSA). According to our survey on Korean literature, a few studies have dealt with daytime sleepiness, and we have not been able to locate any study comparing normal subjects with polysomnography-proven sleep disorder patients regarding daytime sleepiness. We aimed at comparing daytime sleepiness among normal healthy daytime workers, medical students being expected to have daytime sleepiness due to chronic sleep deprivation, and patients having sleep disorders diagnosed with polysomnography. We also studied the association between subjective daytime sleepiness and objective polysomnographic findings in patients with sleep disorders. Methods: One hundred three hospital workers, 137 medical students, and patients with sleep disorders were studied. Sleep disorders included OSA, periodic limb movements in sleep (PLMS), insomnia, and narcolepsy. The degree of subjective sleepiness in each group was measured by the Korean version of Epworth sleepiness scale and compared. The relationship between polysomnographic findings reflecting severity of sleep disorder in each patient group and subjective sleepiness was analyzed. As for patients with narcolepsy, the relationship between the mean sleep latency and subjective sleepiness was studied. Results: There was a significant difference of ESS score (F=68.190, dF=5.752, p<0.001) among daytime workers, medical students, and sleep disorder patients. In OSA patient group, the degree of the sleepiness had no significant correlation either with mean O2 satuaration (p=0.062) or with RDI (p=0.807). In PLMS patient group, there was no correlation between periodic limb movement index (PLMI) and subjective sleepiness (p=0.761). In narcolepsy patient group, the subjective sleepiness had no correlation with mean sleep latency measured with MSLT (p=0.055). Conclusion: We found a significant difference of subjective sleepiness among daytime workers, medical students, and patients with sleep disorders. However, no consistent correlation was found between severity of subjective sleepiness and objective polysomnographic findings reflecting severity of each sleep disorder. This research confirms that the evaluation of subjective sleepiness is important clinically, but it cannot substitute the objective measures such as nocturnal polysomnography and MSLT.

  • PDF

Home Health Care Service Using Routine Vital Sign Checkup and Electronic Health Questionnaires (주기적인 생리변수 측정과 전자건강설문을 이용한 재택건강관리서비스)

  • 박승훈;우응제;이광호;김종철
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.469-477
    • /
    • 2001
  • In this Paper. we describe a home health care service using electronic health questionnaires and routine checkup of vital signs Including ECG (Electrocardiography) , blood pressure. and SpO$_2$ (Oxygen Saturation) . This system is for patients at home with chronic diseases, discharged Patients, or any normal people for the Prevention of disease The service requires a home health care terminal and a PC with Interned connection installed at Patient home. The distance health care management center is equipped with a vital-sign and questionnaire interpreter as well as database, Web, and notification servers with UMS (Unified Messaging System). Participating Physician can access the servers at the center using a Web browser running on a PC available to them at any time. These components are linked together through various kinds of data and voice communication channels including PSTN (Public Switched Telephone Network) . CATV(Community Antenna TV) . Interned. and mobile communication network. Following the Physician's direction given to a Patient. he or she uses the home health care terminal to collect vital signs and fill out the questionnaire. When the terminal automatically transmits these data to the management center. the data interpreter and servers at the center process the information fo1lowing the Protocol implemented on the system. Physicians can retrieve and review data corresponding to their Patients and send back their diagnostic reports to the center. UMS at the center delivers the physician 's recommendation to the corresponding patient through the notification server. Patients can also reprieve and review their own records as well as diagnostic reports from physicians. The system Provides a new way of collecting diagnostic information and delivering doctor's recommendation to patients at home for their health management. Future works are needed in the development of new technology for measurements and interpretations of various vital signs .

  • PDF

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

Clinical Trial of Nasal Flumazenil Administration (플루마제닐의 경비 투여)

  • Hong, Soo-Jin;Kim, Hyun-Jung;Yum, Kwang-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.441-446
    • /
    • 2001
  • Flumazenil is a competitive antagonist of benzodiazepines. It is usually administered intravenously. However, if the intravenous route is not available then other routes of drug administration should be considered. This study was designed to evaluate the reversal effects of flumazenil after nasal administration. Twenty-five young, healthy adult volunteers participated in this clinical trial. The dosage of 0.08mg/kg midazolam was administered intravenously to induce deep sedation. Ten minutes after midazolam administration, 0.5mg of flumazenil was dropped nasally, over a period of one minute. Blood samples were taken to measure the concentration of midazolam and flumazenil at 0, 5, 10, and 20min after nasal administration of flumazenil, using High Performance Liquid Chromatography. The degree of sedation was evaluated with sedation score and bispectral index (BIS), Statistical analysis was performed by multivariate ANOVA and correlation analysis (P<0.05). Peak serum flumazenil concentration was reached in 10min. Sedation score decreased after midazolam administration and showed a significant increase after flumazenil administration. However, BIS decreased during the first 10min after midazolam administration and then no significant changes after flumazenil administration. There were two instances representing rapid and complete reversal of midazolam after intranasal administration of flumazenil. In conclusion, intranasal flumazenil administration may be effective in some patients when intravenous route is not available in condition of benzodiazepine overdose.

  • PDF

Prevalence and Predictors of Nocturia in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성수면무호흡증 환자의 야간뇨 유병률 및 관련인자)

  • Kang, Hyeon Hui;Lee, Jongmin;Lee, Sang Haak;Moon, Hwa Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.1
    • /
    • pp.14-20
    • /
    • 2014
  • Objectives: Several studies suggest that nocturia may be related to obstructive sleep apnea syndrome (OSAS). The mechanism by which OSAS develops nocturia has not been determined. The present study aimed to determine the prevalence of nocturia among adults with OSAS and to identify factors that may be predictive in this regard. Methods: Retrospective review of clinical and polysomnographic data obtained from patients evaluated at the sleep clinics of the St. Paul's Hospital between 2009 and 2012. The urinary symptoms were assessed on the basis of the International Prostate Symptom Score (IPSS). Pathologic nocturia was defined as two or more urination events per night. OSAS was defined as apnea-hypopnea index (AHI) ${\geq}5$. A multivariate analysis using logistic regression was performed to examine the relationship between polysomnographic variables and the presence of pathologic nocturia, while controlling for confounding factor. Results: A total of 161 men >18 years of age (mean age $46.7{\pm}14.1$), who had been referred to a sleep laboratory, were included in the present study. Among these, 27 patients with primary snoring and 134 patients with obstructive sleep apnea were confirmed by polysomnography. Nocturia was found in 53 patients with OSAS (39.6%) and 8 patients with primary snoring (29.6%). The AHI was higher in patients with nocturia than in those without nocturia (p=0.001). OSAS patients with nocturia had higher arousal index (p=0.044), and lower nadir oxyhemoglobin saturation (p=0.001). Multiple regression analysis showed that age (${\beta}$=0.227, p=0.003), and AHI (${\beta}$=0.258, p=0.001) were associated with nocturia, and that the presence of pathologic nocturia was predicted by age (OR 1.04 ; p=0.004) and AHI (OR 1.02 ; p=0.001). Conclusion: Nocturia is common among patients with OSAS. The strongest predictors of nocturia are age and AHI in patients with OSAS.