• Title/Summary/Keyword: 혈액 유동

Search Result 104, Processing Time 0.027 seconds

Flow Visualization of Arteriovenous Grafting Using PIV Technique (PIV 기법을 이용한 동정맥루 문합에 대한 유동가시화)

  • Jeon, Min-Gyu;Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Young Ho;Lee, Hyun-Jin;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.985-990
    • /
    • 2013
  • An arteriovenous fistula is artificially produced using a graft for hemodialysis in patients. In an arteriovenous graft (AVG), the angle of its arterial or venous anastomosis play an important role in producing flows inside blood vessels, through which a stenosis may occur. Most studies thus far have focused on CFD results. In this study, a PIV technique is used to analyze the hemodynamic characteristics at the arterial or venous anastomosis of an AVG having an angle of $30^{\circ}C$. For flow dynamic similarity, the Reynolds number is set to be the same for real and simulated flows. A PIV experiment is performed with a control valve in the arterial part. In conclusion, the recirculation flow appeared in the bifurcation area and the total blood velocity changed according to the extent of valve opening.

In-vitro Study on Hemorheological Behaviors of Blood Flow Through a Micro Tube (미세튜브 내부를 흐르는 혈액유동의 유변학적 특성에 대한 in-vitro 연구)

  • Kang, Myung-Jin;Ji, Ho-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • In order to obtain velocity profile of blood flow with high spatial resolution, a micro PIV technique consisted of a fluorescent microscope, double-pulsed YAG laser, cooled CCD camera was applied to in-vitro blood flow experiment through a micro round tube of a diameter $100{\mu}m$. Velocity distributions of blood flow for rabbit were obtained. The viscosity profiles for shear rate were found at flowing condition. To provide hemorheological characteristics of blood flow, the viscosities for shear rate were evaluated. The viscosity of blood also steeply increase by decreasing shear rate resulting in Non-Newtonian flow, especially in low shear rate region caused by RBC rheological properties. The results show typical characteristics of Non-Newtonian characteristics from the results of velocity profile and viscosity for blood flow. From the inflection points, cell free layer and two-phase flow consisted with plasma and suspensions including RBCs can be separated.

A NUMERICAL ANALYSIS ON BLOOD FLOOD FLOW INSIDE A CAROTID ARTERY WITH THE PATIENT SPECIFIC ARTERIAL GEOMETRY AND BLOOD RHEOLOGY DATA (실제 혈관 형상 및 혈액 특성을 고려한 경동맥 내 혈액 유동에 대한 수치해석 연구)

  • Lee, Sang-Hyuk;Jeong, Seul-Ki;Hur, Nahm-Keon;Cho, Young-Il
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.224-227
    • /
    • 2010
  • In the present study, the characteristics of blood flow inside a carotid artery numerically investigated with shear rate specific blood viscosity. To simulate the blood flow with a patient-specific arterial geometry, the geometry of a carotid artery was constructed from 2D rain MRA data. The measured data of blood flow velocity at the common carotid artery were used as boundary conditions of the simulation. For the blood rheology data to be used in the simulation, the patient specific blood viscosity over the whole ranges of shear rate was obtained using $BioVisco^{TM}$. From the numerical results of the blood flow in the carotid artery, the increase of blood viscosity and the decrease of wall shear stress could be found in the carotid bifurcated region, more specifically at the post-plaque dilated region. These characteristics of blood viscosity and wall shear stress can be used more precisely and efficiently to predict the region vulnerable to plaque growht or thrombosis on top of the plaque.

  • PDF

NUMERICAL STUDY ON BLOOD FLOW CHARACTERISTICS IN A ARTERIOVENOUS GRAFT WITH DELIVERED DOSE DURING HEMODIALYSIS (인조혈관 동정맥루의 혈액 투석량에 따른 인조혈관 내부 유동 특성에 관한 수치해석 연구)

  • Kim, J.Y.;Ro, K.C.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.4
    • /
    • pp.84-91
    • /
    • 2011
  • Hemodialysis is essential for patients with end stage renal failure. It is important to improve the patency rate and to minimize occurrence of the stenosis. Also, the blood flow to the artificial kidney can affect the blood flow characteristics through arteriovenous graft. Thus, the delivered dose are important factors for analyzing hemodynamic characteristics during hemodialysis access. In this study, the numerical analysis was performed for the effect of the delivered dose during hemodialysis access on the blood flow through the graft. As a result, The adverse pressure gradient occurred in case of a larger delivered dose through a catheter than standard dose and the flow instability increased. Also the circulation flow appeared largely at anastomotic site of the vein when the delivered dose was exceeded about half blood flow of inlet blood flow.

Blood Flow Characteristics due to Catheter Insertion in the Eccentric Stenosed Coronary Artery (편심협착부가 있는 관상동맥내 카테터삽입에 따른 혈액유동특성)

  • Roh Hyung-Woon;Suh Sang-Ho;Kwon Hyuk-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.707-708
    • /
    • 2002
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Catheter insertions during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. In general, the form of stenoses are no uniform. Sometimes, these are occurred the irregularly eccentricity If the analyses are conducted for uniform stenosed artery, the results will be underestimated. Thus, in this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter insertion during the coronary angioplasty. The results for the eccentric stenosed artery are compared with those of the concentric stenosed artery.

  • PDF

In Vivo Measurements of Blood Flow in a Chicken Embryo Using Micro PIV Technique (유정란 배아 혈액유동의 in vivo 계측)

  • Yeo Chang-Sub;Han Kyu-Yeon;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.314-319
    • /
    • 2006
  • To analyze in-vivo blood flow characteristics in a chicken embryo, in-vivo experiment was carried out using micro-PIV technique. Because endothelial cells in blood vessels are subject to shear stress of blood flow, it is important to get velocity field information of the placental blood flow. Instantaneous velocity fields of an extraembryonic blood vessel using a high-speed camera and intravital microscope. The flow images of RBCs were obtained with a spatial resolution of $20\times20{\mu}m$ in the whole blood vessels. The mean velocity field data confirm that the blood flow does show non-Newtonian fluid characteristic. The blood in a branched vessel merged smoothly without any flow separation into the main blood vessel with the presence of a slight bump. This in-vivo micro-PIV measurement technique can be used as a powerful tool in various blood flow researches.

Numerical Study on Blood Flow Characteristics in a Arteriovenous Graft with Delivered dose During Hemodialysis (혈액 투석 시 주사침에서의 투석량에 따른 인조혈관 내부 유동 특성에 관한 수치해석 연구)

  • Kim, J.Y.;Ro, K.C.;Ryou, H.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.469-476
    • /
    • 2011
  • Hemodialysis is essential for patients with end stage renal failure. It is important to improve the patency rate and to minimize occurrence of the stenosis. Also, the blood flow to the artificial kidney can affect the blood flow characteristics though arteriovenous graft. Thus, the delivered dose are important factors for analyzing hemodynamic characteristics during hemodialysis access. In this study, the numerical analysis was performed for the effect of the delivered dose during hemodialysis access on the blood flow through the graft. As a result, The adverse pressure gradient occurred in case of a larger delivered dose through a catheter than standard dose and the flow instability increased. Also the circulation flow appeared largely at anastomotic site of the vein when the delivered dose was exceeded about half blood flow of inlet blood flow.

  • PDF