• 제목/요약/키워드: 헤테로폴리산 침출

검색결과 2건 처리시간 0.016초

Direct Conversion of Cellulose into Polyols over Pt/CsxH3-xPW12O40

  • You, Su Jin;Baek, In Gu;Park, Eun Duck
    • 청정기술
    • /
    • 제19권1호
    • /
    • pp.13-21
    • /
    • 2013
  • 다른 분율의 Cs이 포함된 Pt/$Cs_xH_{3-x}PW_{12}O_{40}$ 촉매를 제조하여 셀룰로우스의 폴리올로의 수소화분해반응를 수행하였다. 촉매의 비표면적과 Pt의 분산도는 Pt/$Cs_xH_{3-x}PW_{12}O_{40}$ 촉매의 Cs 함량이 증가함에 따라 증가하였다. 그러나 Pt/$Cs_xH_{3-x}PW_{12}O_{40}$ 촉매의 Cs의 함량이 변함에도 불구하고 비슷한 폴리올 수득률을 보였다. Pt/$Cs_xH_{3-x}PW_{12}O_{40}$ 촉매의 반응 활성은 Ni/W/SBA-15와 두 가지의 복합촉매(Pt/AC+$H_3PW_{12}O_{40}$과 Pt/AC+$Cs_{3.0}PW_{12}O_{40}$)와 비슷하였다. 이 반응을 진행하는 동안 Pt/$Cs_xH_{3-x}PW_{12}O_{40}$ 촉매로부터 헤테로폴리 음이온이 침출되는 것을 확인하였다.

$Cs^+$치환에 따른 수전해용 공유가교 SPEEK/HPA 복합막의 안정화 (Stabilization of Covalently Cross-Linked SPEEK/Cs-Substituted HPA Composite Membranes for Water Electrolysis)

  • 지봉철;하성인;송민아;정장훈;문상봉;강안수
    • 한국수소및신에너지학회논문집
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2011
  • To improve the mechanical properties, such as durabilities and antioxidative characteristics, the covalently cross-linked (CL-) SPEEK (sulfonated polyether ether ketone)/Cs-substituted HPA (heteropoly acid) organic-inorganic composite membranes (CL-SPEEK/Cs-HPAs), have been intensively investigated. The composite membrane were prepared by blending cesium-substituted HPAs (Cs-HPAs), including tungstophosphoric acid (TPA), molybdophosphoric acid (MoPA), and tungstosilicic acid (TSiA) with cross-linking agent content of 0.01 mL. And composite electrolytes composed of Cs-HPAs, prepared by immersion (imm.) and titration (titr.) methods to increase the stability of HPAs in water, were applied to polymer electrolyte membrane electrolysis (PEME). As a result, the proton conductivity of Cs-substituted composite membranes increased rapidly over $60^{\circ}C$ but mechanical properties, such as tensile strength, decreased in accordance with added Cs content. The bleeding-out of Cs-TPA membranes by titration method (50 vol.% Cs) decreased steadily to 2.15%. In the oxidative stability test by Fenton solution, the durability of membranes with Cs-HPA significantly increased. In case of CL-SPEEK/ Cs-TPA membrane, duration time increased more than 1200 hours. It is expected that even though CL-SPEEK/Cs-MoPA membrane shows the high proton conductivity, electrocatalytic activity and cell voltage of 1.80 V for water electrolysis, the CL-SPEEK/Cs-TPA (imm.) is more suitable as an alternative membrane in real system with the satisfactory proton conductivity, mechanical properties, anti-oxidative stability and cell voltage of 1.89 V.