• Title/Summary/Keyword: 허용변위

Search Result 197, Processing Time 0.027 seconds

Experimental Investigation of Lateral Retrofitting Effect with CFRP and BRB (Buckling-Restrained Brace) for Beam-column Joints of Low-Rise Piloti Buildings (탄소섬유시트와 비좌굴 가새를 이용한 저층 필로티 구조물의 보-기둥 연결부의 횡방향 보강효과에 관한 실험적 연구)

  • Seo, Sang-Hoon;Yoo, Yeon-Jong;Lee, Young-Hak;Kim, Hee-Cheul;Lee, Ki-Hak;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2009
  • The purpose of this study is to evaluate the structural capacities of beam-column specimens retrofitted with CFRP sheet and BRB (Buckling-Restrained Brace) under sustained axial and cyclic lateral loads. Three specimens were made using different retrofitting methods : non-retrofitted, retrofitted with CFRP sheets only, and retrofitted with both CFRP sheet and BRB systems. Lateral load resistant capacities were evaluated based on the load-displacement relations. From the results, the maximum lateral forces of the FRP sheet retrofitted and both the FRP and BRB retrofitted specimens showed approximately 34% and 138% improvement, respectively, compared with the non-retrofitted specimen.

Seismic Performance Evaluation of Complex-Shaped Tall Buildings by Lateral Resisting Systems (횡력저항시스템에 따른 비정형 초고층건물 내진성능평가)

  • Youn, Wu-Seok;Lee, Dong-Hun;Cho, Chang-Hee;Kim, Eun-Seong;Lee, Dong-Chul;Kim, Jong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.513-523
    • /
    • 2012
  • The objective of this research is to examine how the lateral resisting system of selected prototypes are affected by seismic zone effect and shape irregularity on its seismic performance. The lateral resisting systems are divided into the three types, diagrid, braced tube, and outrigger system. The prototype models were assumed to be located in LA, a high-seismicity region, and in Boston, a low-seismicity region. The shape irregularity was classified with rotated angle of plane, $0^{\circ}$, $1^{\circ}$, $2^{\circ}$. This study performed two parts of analyses, Linear Response and Non-Linear Response History(NLRH) analysis. The Linear Response analysis was used to check the displacement at the top and natural period of models. NLRH analysis was conducted to invest base shear and story drift ratio of buildings. As results, the displacement of roof and natural period of three structural systems increase as the building stiffness reduces due to the changes in rotation angle of the plane. Also, the base shear is diminished by the same reason. The result of NLRH, the story drift ratio, that was subject to Maximum Considered Earthquake(MCE) satisfied 0.045, a recommended limit according to Tall Building Initiative(TBI).

Creep Effect of Shallow Plate Anchor in Soft Clsy

  • Shin, Eun-Chul;Das, Braja
    • Geotechnical Engineering
    • /
    • v.12 no.3
    • /
    • pp.63-72
    • /
    • 1996
  • Plate anchors are often used for various types of offshore construction and maintenance works. When the plates are embedded in soft clay and subjected to sustanined allowable loads, creep may develop. This paper presents some results from laboratory model test designed to study the creep effect that develops with time for a shallow circular anchor subjected to sustained net loads that are less than the net ultimate uplift capacity. Based on the model test results, relationships among the net load, the rate of strain, and time are developed.

  • PDF

A Study of Crack Growth Behavior of Al2024 (Al2024의 균열성장거동에 관한 연구)

  • Lee, Won-Seok;Lee, Hyun-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.49-55
    • /
    • 2000
  • This study describes the fatigue characteristics for Al2024 alloy, which is aircraft structure material. For this work, the plane-strain fracture toughness test, the plane-stress fracture toughness test and the crack growth rates test were conducted under the standard testing method. Test equipment is a computer-controlled closed-loop fatigue testing machine. The data of each test result is very important to aircraft structure reliability estimation, life prediction, design analysis, endurance analysis and damage tolerance analysis. In addition, the fatigue crack growth threshold($\DeltaKth$) value decreased as the stress ratio increased. Also, $\DeltaKth$ decreased as the thickness increased in LT, TL directions.

  • PDF

The Verification Test for the Primary Piping System of Nuclear Power Plant (원자력 발전소 1차계통 배관 건전성 평가)

  • Lee, Hyun;Kim, Yearn-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.318-321
    • /
    • 1995
  • 원자력 발전소의 안전성 보장 및 신뢰성 향상을 위하여 시운전 단계에서 원자력 발전소내 안전등급에 해당하는 배관계통의 상태 확인을 위하여 각종시험을 하도록 되어있다. 특히 새로운 설계기념, 크기 또는 용량을 갖는 원자로 모델에 대해서는 필수적으로 건전성 평가를 하게 되었다. 이를 위해 발전소 건설기간에 시행하는 고온 기능시험 중에 원자로 주변 주요 시스템인 원자로 냉각재 루프 계통에 대한 건전성 확인을 위해 압전형 고온 가속도 센서를 이용하여 정상운전상태의 진동을 측정하여 시스템 진동거동을 규명하였다. 배관시스템의 일상운전상태는 유체의 흐름과 기기운전이 일정한 정상상태와 펌프의 기동 또는 정지 및 밸브의 급격한 개폐등으로 발생하는 과도상태로 나눌 수 있다. 따라서 두 가지 상태의 진동을 측정해야 한다. 배관계통은 정상운전 상태로 설계수명을 유지할 수 있어야 하므로 정상진도잉 최소화 되어야 한다. 진동 평가기준은 배관재질의 응력(S/N 커브) 곡선을 참조하여 설계수명내에 손상이 일어나지 않도록 재료의 허용응력을 산정하고 이를 진동변위로 환산하여 정한 것이며 이 값에 측정 데이타를 비교하여 1차계통 배관의 건전성을 확인하였다.

  • PDF

Optimization of Steel Jacket Subjected to Wave Forces (파랑하중을 받는 Steel Jacket의 최적화에 관한 연구)

  • 장승필;이원표;원종국
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.2 no.1
    • /
    • pp.43-50
    • /
    • 1990
  • This study is concerned with the optimization of steel jacket subjected to wave forces using the allowable stress design method. The optimization of member section is considered here. Objective function for the minmum cost design is obtained by considering the weight of steel jecket. Constraints are imposed to insure that structural displacement and strength are within allowable values. The nonliner otimization problems are solved by SUMT method including the modified Newton-Raphson method.

  • PDF

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Design of Flat Plate Systems Using the Modified Equivalent Frame Method (수정된 등가골조법을 이용한 플랫플레이트 시스템의 설계)

  • Park, Young-Mi;Oh, Seung-Yong;Han, Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • In general, flat plate systems have been used as a gravity load resisting system (GLRS) in building. Thus, this system should be constructed with lateral force resisting system (LFRS) such as shear walls and brace frames. GLRS should retain the ability to undergo the lateral drift associated with the LFRS without loss of gravity load carrying capacity. And flat plate system can be designed LFRS as ordinary moment frame with the special details. Thus, flat plate system designed as GLRS or LFRS should be considered internal forces (e.g., unbalanced moments) and lateral deformation generated in vicinity of slab joints render the system more susceptible to punching shear. ACI 318 (2005) allows the direct design method, equivalent frame method under gravity loads and allows the finite-element models, effective beam width models, and equivalent frame models under lateral loads. These analysis methods can produce widely different result, and each has advantage and disadvantages. Thus, it is sometimes difficult for a designer to select an appropriate analysis method and interpret the results for design purposes. This study is to help designer selecting analysis method for flat plate system and to verify practicality of the modified equivalent frame method under lateral loads. This study compared internal force and drift obtained from frame methods with those obtained from finite element method under gravity and lateral loads. For this purposes, 7 story building is considered. Also, the accuracy of these models is verified by comparing analysis results using frame methods with published experimental results of NRC slab.

Inelastic Time History Analysis of a 5-Story RC OMRF Considering Inelastic Shear Behavior of Beam-Column Joint (보-기둥 접합부 비탄성 전단거동을 고려한 5층 철근콘크리트 보통모멘트골조의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Kim, Tae-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.633-641
    • /
    • 2012
  • In this study, the effects of the inelastic shear behavior of beam-column joint on the response of RC OMRF are evaluated in the inelastic time history analysis. For an example, a 5-story structure for site class SB and seismic design category C was designed in accordance with KBC2009. Bending moment-curvature relationship for beam and column was evaluated using fiber model and bending moment-rotation relationship for beam-column joint was calculated using simple and unified joint shear behavior model and moment equilibrium relationship. The hysteretic behavior was simulated using three-parameter model suggested in IDARC program. The inelastic time history analysis with PGA for return period of 2400 years showed that the model with inelastic beam-column joint yielded smaller maximum base shear force but nearly equivalent maximum roof displacement and maximum story drift as those obtained from analysis using rigid joint. The maximum story drift satisfied the criteria of KBC2009. Therefore, the inelastic shear behavior of beam-column joint could be neglected in the structural design.

A finite element analysis of implant-supported overdenture on the effect of anterior cantilever (임플랜트 bar overdenture에서 bar의 cantilever양이 임플랜트에 미치는 영향에 관한 삼차원 유한요소분석적 연구)

  • Jung, Tae-Wook;Kim, Young-Soo;Kim, Chang-Whe;Ling, Booi-Cie
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.1-17
    • /
    • 1998
  • 두개의 임플랜트로 지지되는 overdenture를 이용한 하악무치악환자의 치료법은 경제적이면서, 실용적인 치료로 인정을 받고 있다. 하지만 해부학적인 조건으로 임플랜트를 설측 혹은 후방에 식립해야 되는 경우에는 일반적인 bar설계는 bar가 구강저 상방을 지나게 되어 혀운동, 발음, 위생관리 등에 많은 문제점을 부여한다. 이에 대한 해결방법으로 전방부 치조제 상에 보철물의 회전을 허용하는 angular bar를 설계할 수 있다. 하지만 이 설계는 임플랜트에 불리한 moment를 유발한다. 그럼에도 불구하고 뛰어난 유지력과 지지능력, 경제적인 면 때문에 angular bar는 임상에서 많이 사용되고 있다. 이에 본 연구는 angular bar의 전방 cantilever양을 달리하여 임플랜트 및 주변조직에 미치는 영향을 삼차원 유한요소분석법을 통해서 알아보고자 하였다. 이공사이의 하악골을 단순화시킨 준하악골모형에 직경 3.75mm인 브로네마르크 임플랜트 2개를 길이가 13,15mm인 경우로 설정하여 제 1소구치 부위에 식립하였다. 두 임플랜트를 연결하는 bar는 전방부 cantilever양을 0-5mm, 1mm씩 하여 6가지 경우를 가정하고 제작하였다. 각각 bar 중앙부에 수직압 (90도) 35N, 경사압(120도) 70N, 수평압(0도) 10N을 가하였으며 이때 나타나는 응력 분산형태와 임플랜트의 골유착에 불리하게 작용하는 최대주응력(인장력)과 변위량을 살펴보았다. 연구결과 다음과 같은 결론을 얻었다. 1. Cantilever양이 증가할수록 주변피질골과 임플랜트로 응력이 집중되었으며 상부 보철물의 변위량도 커졌다. 2. Cantilever양에 대한 수평압의 영향은 크지 않았으며 임플랜트 길이가 긴 것이 변위량과 응력이 작았다. 3. 경사압에 대한 응력의 변화는 cantilever양의 증가에 따라 급격히 증가하는 양상을 띠었으며 임플랜트길이가 응력 및 변위의 양에 미치는 영향은 없었다. 4. 수직압에 대한 응력의 변화는 초기에는 완만한 증가를 보이다가 일정 시점 지난 후에는 증가율이 커지는 경향을 띠었다. 증가현상이 두드러지기 전에는 길이의 증가가 응력의 분산효과는 가져왔으나 이후에는 길이의 응력분산 효과는 없었다. 5. 응력분포양상은 cantilever양이 증가할수록 골조직을 통한 분산정도는 작아지고 특정부위의 피질골과 임플랜트, 상부보철물에 집중되는 경향을 보였다. 6. 임플랜트와 주변 골조직으로의 응력분산능력이 예후를 좌우한다는 점에서 angular bar는 적합치 못하며 부득이한 경우는 임플랜트 길이를 길게 하고 최대한 3mm이내로 cantilever양을 제한하는 것이 추천된다.

  • PDF