• Title/Summary/Keyword: 행렬식

Search Result 482, Processing Time 0.022 seconds

A Study on the Validity of Technology Innovation Aid Programs for IT Small and Medium-sized Enterprises: Focusing on the Dynamic Characteristics and Relationship (IT중소기업 기술혁신 지원사업의 타당성 연구: 동태적 특성 및 연관성을 중심으로)

  • Park, Sung-Min;Kim, Heon;Sul, Won-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10B
    • /
    • pp.946-961
    • /
    • 2008
  • This study aims to provide guidelines on future policy for restructuring the scheme of aid programs associated with If small and medium-sized enterprises (i.e. SME) in Korea. For this purpose, we investigate an empirical dataset of recent aid programs deployed by Ministry of Information and Communication (i.e. MIC) for the last four years First, it is examined that the programs are practiced in accordance with their own policy objective by comparing matching samples between two groups such as program beneficiary and non-beneficiary companies. Second, positioning transition of programs within a same category is visualized in terms of two business portfolio analysis matrices. Third, an affiliation network matrix of (he programs is newly developed and then we attempt to analyze the programs relationship by the application of multidimensional scaling method to the affiliation network matrix. The empirical dataset is composed of two different kinds of corporate datasets. One is a corporate dataset of 8,994 beneficiary companies that are aided by MIC during the year of '03-'06. The other is also a corporate dataset of 18,354 non-beneficiary companies that have no records of the program supports during the years at all. Particularly, the matching samples of non-beneficiary companies are prepared in order to have comparable corporate age years (i.e. CAY) against beneficiary companies' CAY. Results show that; 1) up-to-date, the programs are properly assigned to IT SME conforming to their own policy objective; 2) however, as the year goes on, the following two distinct positioning transitions are revealed such as (1) both CAY and corporate sales (i.e. SAL) are increased simultaneously, (2) ratio of intangible assets (i.e. RIA) is decreased and ratio of operating gain to revenue (i.e. ROR) is increased. Hence, the role of the programs gets weakened with regard to providing seed money to technology innovation-typed IT SME so that a managerial adjustment of the programs is required consequently; 3) even though the model adequacy is not satisfactory through the analysis of multidimensional scaling method, the relationship of indirect-typed programs can relatively be stronger than that of direct-typed programs.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.