• Title/Summary/Keyword: 핵능력

Search Result 127, Processing Time 0.026 seconds

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF

A Study of Kuwoonmong Writing and Enjoyment in the Aspects of Yin-Yang (陰陽) and Wu Xing (五行) Imagination (음양오행적 상상력에 기반한 <구운몽>의 창작과 향유 방식 연구)

  • Hwang, Hye-jin
    • Journal of Korean Classical Literature and Education
    • /
    • no.35
    • /
    • pp.153-193
    • /
    • 2017
  • This study explores the creation and enjoyment of Kuwoonmong (九雲夢) using a reference system called the cultural imagination, which is related to the Yin-Yang (陰陽) and Wu Xing (五行). When Kim Manjung wrote Guwoonmong, he may have composed figures and events based on this imagination. In particular, when he designed the eight seonnyeo (팔선녀), he set the order such as Gap (甲), Eul (乙), Byeong (병), Jeong (丁), etc. and characterized them according to the celestial stem (天干). Thus it was easy to avoid overlapping of characters and to construct various stories and relationships between them. The table below shows the characters of Kuwoonmong corresponding to the celestial stem. In not only the individual person but also the narrative world, Kuwoonmon demonstrates Yin-Yang and Wu Xing's imagination. In this respect, Kuwoonmon can be considered a large symbol encompassing the abstract theory of Yin-Yang and Wu Xing. Of course, the writer, Kim, Manjung would not have tried to symbolize the principle intentionally. However, he was also present in the environment of the cultural imagination that has been formed over the years. The same is true for the contemporary recipients of Guwunmong. They would have had a pleasant experience applying the cultural imagination and strengthening their familiar world view and human view.

CELL CULTURE STUDIES OF MAREK'S DISEASE ETIOLOGICAL AGENT (조직배양(組織培養)에 의한 Marek 병(病) 병원체(病原體)의 연구(硏究))

  • Kim, Uh-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.9 no.1
    • /
    • pp.23-62
    • /
    • 1969
  • Throughout the studies the following experimental results were obtained and are summarized: 1. Multiplication of agents in primary cell cultures of both GF classical and CR-64 acute strain of Marek's disease infected chicken kidneys was accompanied by the formation of distinct transformed cell foci. This characteristic nature of cell transformation was passaged regularly by addition of dispersed cell from infected cultures to normal chicken kidney cell cultures, and also transferred was the nature of cell transformation to normal chick-embryo liver and neuroglial cell cultures. No cytopathic changes were noticed in inoculated chick-embryo fibroblast cultures. 2. The same cytopathic effects were noticed in normal kidney cell monolayers after the inoculation of whole blood and huffy coat cells derived from both forms of Marek's disease infected chickens. In these cases, however, the number of transformed cell foci appearing was far less than that of uninoculated monolayers prepared directly from the kidneys of Marek's disease infected chickens. 3. The change in cell culture IS regarded as a specific cell transformation focus induced by an oncogenic virus rather than it plaque in slowly progressing cytopathic effect by non-oncogenic viruses, and it is quite similar to RSV focus in chick-embryo fibroblasts in many respects. 4. The infective agent (cell transformable) were extremely cell-associated and could not be separated in an infective state from cells under the experimental conditions. 5. The focus assay of these agents was valid as shown by the high degree of linear correlation (r=0.97 and 0.99) between the relative infected cell concentration (in inoculum) and the transformed cell foci counted. 6. No differences were observed between the GF classical strain and the CR-64 acute strain of Marek's disease as far as cell culture behavior. 7. Characterization of the isolates by physical and chemical treatments, development of internuclear inclusions in Infected cells, and nucleic acid typing by differential stainings and cytochemical treatments indicated that the natures of these cell transformation agents closely resemble to those described fer the group B herpes viruses. 8. Susceptible chicks inoculated with infected kidney tissue culture cells developed specific lesions of Marek's disease, and in a case of prolonged observation after inoculation (5 weeks) the birds developed clinical symptoms and gross lesions of Marek's disease. Kidney cell cultures prepared from those inoculated birds and sacrificed showed a superior recovery of cell transformation property by formation of distinct foci. 9. Electron microscopic study of infected kidney culture cells (GF agent) by negative staining technique revealed virus particles furnishing the properties of herpes viruses. The particle was measured about $100m{\mu}$ and, so far, no herpes virus envelop has been seen from these preparations. 10. No relationship of both isolates to avian leukosis/sarcoma group viruses and PPLO was observed.

  • PDF

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

Professional Speciality of Communication Administration and, Occupational Group and Series Classes of Position in National Public Official Law -for Efficiency of Telecommunication Management- (통신행정의 전문성과 공무원법상 직군렬 - 전기통신의 관리들 중심으로-)

  • 조정현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.3 no.1
    • /
    • pp.26-27
    • /
    • 1978
  • It can be expected that intelligence and knowledge will be the core of the post-industrial society in a near future. Accordingly, the age of intelligence shall be accelerated extensively to find ourselves in an age of 'Communication' service enterprise. The communication actions will increase its efficiency and multiply its utility, indebted to its scientic principles and legal idea. The two basic elements of communication action, that is, communication station and communication men are considered to perform their function when they are properly supported and managed by the government administration. Since the communication action itself is composed of various factors, the elements such as communication stations and officials must be cultivated and managed by specialist or experts with continuous and extensive study practices concerned. With the above mind, this study reviewed our public service officials law with a view to improve it by providing some suggestions for communication experts and researchers to find suitable positions in the framework of government administration. In this study, I would like to suggest 'Occupational Group of Communication' that is consisted of a series of comm, management positions and research positions in parallel to the existing series of comm, technical position. The communication specialist or expert is required to be qualified with necessary scientific knowledge and techniques of communication, as well as prerequisites as government service officials. Communication experts must succeed in the first hand to obtain government licence concerned in with the government law and regulation, and international custom before they can be appointed to the official positions. This system of licence-prior-to-appointment is principally applied in the communication management position. And communication research positions are for those who shall engage themselves to the work of study and research in the field of both management and technical nature. It is hopefully expected that efficient and extensive management of communication activities, as well as scientific and continuous study over than communication enterprise will be upgraded at national dimensions.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF