• Title/Summary/Keyword: 항주파고

Search Result 43, Processing Time 0.017 seconds

A Study on Efficiency Improvement of X-Band Power Amplifier Using Harmonic Control Circuit (고조파 제어 회로를 이용한 X-대역 전력 증폭기의 효율 개선에 관한 연구)

  • Kim, Hyoung-Jong;Choi, Jin-Joo;Kim, Dong-Yoon;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.987-994
    • /
    • 2010
  • In this paper, a simple and effective active load-pull method is proposed, and the method to improve the efficiency of X-band power amplifier using harmonic control circuit is presented. The proposed active load-pull system mainly consists of directional coupler, phase shifter, short circuit, and power amplifier, and allows a user to access reflection coefficients near the edge of the Smith chart($\Gamma$=1) easily. The device used in this paper is Mitsubishi's GaAs FET MGF1801, and the operating frequency of the power amplifier is 9 GHz, The amplifier had output power of 21.65 dBm and drain efficiency of 24.9 % at class-A, and had output power of 21.46 dBm and drain efficiency of 53.3 % at class-AB. Harmonic control circuit is designed only second and third harmonic components because of the bandwidth limitation of the microwave components. The drain efficiency is improved as much as 6.4 % compared with class-AB power amplifier.

Effects of Regional Hyperthermia with Moderate Temperature on Cancer Treatment (국부 중등도 온열요법의 암치료 효과)

  • Kang, Chi-Dug;Kim, Sun-Hee
    • Journal of Life Science
    • /
    • v.26 no.9
    • /
    • pp.1088-1096
    • /
    • 2016
  • Despite that moderate hyperthermia can exert various antitumor activities such as direct cytotoxic effects on tumor cells, effects on tumor vasculatures and immunological effects, hyperthermia has been usually combined with radiotherapy or chemotherapy due to its limited efficacy in cancer treatment, showing some positive clinical benefits with generally well-tolerated side effects. Since heat shock responses itself can interfere with the anti-tumor effects of hyperthermia, not all of these studies might have demonstrated positive clinical outcomes in cancer patients. Therefore, the negative anti-tumor effect of hyperthermia should be reduced to enhance the effectiveness of hyperthermia. Although the responses to heat stress of tumor tissues containing vessels, immune cells, connective tissues as well as cancer cells, are very complicated, it is needed to study in the near future if some clinically available drugs, which can modulate heat stress responses, can improve the efficacy of hyperthermia in patients with cancer. In this review, the effect of clinical hyperthermia centered on non-invasive external hyperthermia using radiofrequency at moderate temperature will be discussed, since it is the state-of-the-art technology in the current clinical practice of hyperthermia, and a moderate operational temperature is used to increase the therapeutic effectiveness of conventional therapy without additional toxicity to normal tissues.

The Phase-Shift Method for the Langmuir Adsorption Isotherms of Electroadsorbed Hydrogens for the Cathodic H2 Evolution Reactions at the Poly-Pt Electrode Interfaces (다결정 Pt 전극계면에서 음극 H2 발생반응을 위한 전착된 수소의 Langmuir 흡착등온식에 관한 위상이동 방법)

  • Chun, Jang H.;Jeon, Sang K.;Lee, Jae H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.3
    • /
    • pp.131-142
    • /
    • 2002
  • The Langmuir adsorption isotherms of the under-potentially deposited hydrogen (UPD H) and the over-potentially deposited hydrogen (OPD H) at the poly-Pt/0.5M $H_2SO_4$ and 0.5 M LiOH aqueous electrolyte interfaces have been studied using cyclic voltammetric and ac impedance techniques. The behavior of the phase shift $(0^{\circ}{\leq}{-\phi}{\leq}90^{\circ})$ for the optimum intermediate frequency corresponds well to that of the fractional surface coverage $(1{\geq}{\theta}{\geq}0)$ at the interfaces. The phase-shift method, i.e., the phase-shift profile $({-\phi}\;vs.\;E)$ for the optimum intermediate frequency, can be used as a new electrochemical method to determine the Langmuir adsorption isotherms $({\theta}\;vs.\;E)$ of the UPD H and the OPD H for the cathodic $H_2$ evolution reactions at the interfaces. At the poly-Pt/0.5M $H_2SO_4$ aqueous electrolyte interface, the equilibrium constant (K) and the standard free energy $({\Delta}G_{ads})$ of the OPD H are $2.1\times10^{-4}$ and 21.0kJ/mol, respectively. At the poly-Pt/0.5M LiOH aqueous electrolyte interface, K transits from 2.7(UPD H) to $6.2\times10^{-6}$ (OPD H) depending on the cathode potential (E) and vice versa. Similarly, ${\Delta}G_{ads}$ transits from -2.5kJ/mol (UPD H) to 29.7kJ/mol (OPD H) depending on I and vice versa. The transition of K and ${\Delta}G_{ads}$ is attributed to the two distinct adsorption sites of the UPD H and the OPD H on the poly-Pt surface. The UPD H and the OPD H on the poly-Pt surface are the independent processes depending on the H adsorption sites themselves rather than the sequential processes for the cathodic $H_2$ evolution reactions. The criterion of the UPD H and the OPD H is the H adsorption sites and processes rather than the $H_2$ evolution reactions and potentials. The poly-Pt wire electrode is more efficient and useful than the Pt(100) disc electrode for the cathodic $H_2$ evolution reactions in the aqueous electrolytes. The phase-shift method is well complementary to the thermodynamic method rather than conflicting.