• Title/Summary/Keyword: 항응고제

Search Result 103, Processing Time 0.019 seconds

Embolectomy of Arteries of Extremities -Clinical analysis of 26 cases (사지동맥의 색전제거술 -26례의 분석-)

  • 강종렬;구본일
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.172-178
    • /
    • 1997
  • We present a etrospective analysis of arterial embolectomies performed at the Inje University Seoul Paik Hospital. During the period of March 1987 Feburary 1996 twenty-six patients underwent embolectomies, eighteen patients were male and eight patients were female, mean age of patients was 56.8 years. Rest pain was the chief complaint in 24 patients, the remaining two patients complained of long term history of claudication after recovery of acute symtoms. But only 10 patients had sensBrylmotor symtoms. Heart was the most common source of embolization and frequent predisposing factor of embolism was ischemic heart disease in 8 cases and valvular heart disease in 11 cases. The sites of embolization were upper extremities artery in 6 cases, saddle embolism in 2 cases, lower extremities artery in 18 cases and the most common site of embolism was femoral artery in 1 1 cases. Preoperative angiography was taken in the diagnosis and planning of the embolectomy in 1) patients while in the other patient p eoperative angiography was not taken. Only two cases were operated within the golden period of 6 hours and other cases were operated in more than 6 hours after embolization. In all patients, the Fogarty embolectomy catheter was used without bypass surgery via bachial ateriotomy in the embolism of upper extremities artery, bilateral groin approaches in the saddle embolism and transfemoral approach in the embolism of lower extremities artery. However 3 patients were re-operated via transpopliteal approach in the distal poplitiotibial embolism. Eighteen patients received perioperative anticoagulation therapy by heparin or fraxiparine and wafarin was used in 17 patients at the time of discharge and the indication of anticogulation was patients of valvular heat disease andfor atrial fibrillation, peripheral artery atherosclerosis and recurrent embolism. Postoperative results of the embolectomy were as follows: fouteen pateints had excellent results, five cases had symtom improvement after re-operation, B. K. amputation in 1 case who had severe atherosclerosis of lower extremities, recurrent embolism in 1 case and death in 2 cases the cause of death were acute renal failure and cerebral artery embolism, respectively. The complications of the embolectomy were reperfusion syndrome, pseudoaneurysm and intimal dissection in one case each. Conclusively the problems of embolism is delayed diagnosis and increasing number of old aged patient who had suffered from ischemic heart diease. Preoperative angiography was not always needed for embol ectomy. Selective anticoagulation therapy can decrease incidence of re-embolism. In the distal poplitiotibial embolism, embolectomy of tibial artery was difficult.

  • PDF

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves (이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.430-438
    • /
    • 2008
  • Background: All the patients with mechanical valves require warfarin therapy in order to prevent them from developing thromboembolic complications. According to the ACC/AHA practice guidelines, after AVR with bileaflet mechanical prostheses in patients with no risk factors, warfarin is indicated to achieve an INR of 2.0 to 3.0. After MVR with any mechanical valve, warfarin is indicated to achieve an INR of 2.5 to 3.5. But in our clinical experience, bleeding complications (epistaxis, hematuria, uterine bleeding, intracerebral hemorrhage etc.) frequently developed in patients who maintained their INR within this value. So, we retrospectively reviewed the patients with bileaflet mechanical heart valve prosthesis and we determined the optimal anticoagulation value. Material and Method: From January 1984 to February 2007, 311 patients have been followed up at a national medical center. We classified the AVR patients (n=60) into three groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II and an INR from 2.5 to 3.0 in Group III. We classified the MVR (n=171) and DVR (n=80) patients into four groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II, an INR from 2.5 to 3.0 in Group III and an INR from 3.0 to 3.5 in Group III. We compared the groups for their thromboembolic and bleeding complications by means of the Kaplan Meier method. Result: In the AVR patients, 2 thromboembolic complications and 4 bleeding complications occurred and the log rank test failed to identify any statistical significance between the groups for thethromboembolic complication rate, but groups I and II had lower bleeding complication rates than did group III. Thirteen thromboembolic complication and 15 bleeding complication occurred in the MVR and DVR patients, and the log rank test also failed to identify statistical significance between the groups for the thromboembolic complication rate, but groups I and II had lower bleeding complication rates that did groups III and IV. Conclusion: The thromboembolic complication rate was not statistically different between groups I and II and groups III and IV, but the bleeding complication rates of groups I and II were lower than those of groups III and IV. So this outcome encouraged us to continue using our low intensive anticoagulation regime, that is, an INR of 1.5 to 2.5.

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

The risk factors for implant survival and marginal bone loss: a retrospective long-term study (임플란트 장기간 유지와 변연골 소실에 영향을 주는 요인들에 대한 후향적 연구)

  • Lee, Eun-Woo;Jung, Ha-Na;Jo, Yujin;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.97-109
    • /
    • 2022
  • Purpose: This study aims to investigate the risk indicators contributing to implant failure, and analyze the relationship between risk indicators and marginal bone loss (MBL) through long-term follow-up over 3 years. Materials and Methods: From 2003 to 2017, patients' medical charts with a history of dental implant surgery at Chonnam National University Dental Hospital were reviewed retrospectively. The patient's demographic variables, and clinical variables were recorded. Periapical radiographs were used to evaluated the changes in MBL around implants. And we analyzed implant survival rates. Multiple regression analysis with backward elimination was conducted to correlate the patient's clinical variables and implant failure and Pearson correlation analysis was performed to the correlated between implant long-term survival rates and MBL and initial stability. Results: In multiple regression analysis, there was a statistically significant negative correlation between abutment connection type (β = -.189, P < .05), with or without SPT (β = -.163, P < .05), diabetes (β = -.164, P < .05), osteoporosis (β = -.211, P < .05) and MBL. Anticoagulant medication influenced the long-term success rate of implants. PTV values at the second implant surgery showed a statistically significant negative correlation with long-term implant survival (P < .05). Conclusion: For the long-term success of the implant, the appropriate abutment connection type must be selected and the periodic SPT is recommended. Systemic diseases such as diabetes and osteoporosis and anticoagulant medication should be considered. Furthermore, since high PTV at the second implant surgery correlated with the long-term survival rates of the implant, initial stability should be carefully considered before undergoing the prosthetic procedure.

Surgical Treatment for Renovascular Hypertension and Iliac Artery Occlusion (신혈관성 고혈압 및 장골동맥 폐쇄에 대한 수술)

  • Ryu, Kyoung-Min;Ryu, Jae-Wook;Park, Seong-Sik;Kang, Tae-Soo;Kim, Seok-Kon;Seo, Pil-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.582-586
    • /
    • 2007
  • A 48-year old male patient visited our hospital with uncontrolled hypertension and pair of the left leg. CT angiography shows atherosclerotic occlusion of both renal artery orifices and the left common iliac artery. Despite of medical treatment for 2 months, the clinical condition of the patient worsened. We performed the surgical revascularization with both renal arteries and aorto-left femoral artery bypass with using an 8 mm artificial vascular graft. He lived well without hypertension with using only angiotensin receptor blocker and an anticoagulant for 10 postoperative months. Using surgical revascularization for renovascular hypertension has decreased due to the development of intervention technology and medication, but this surgery is indicated in cases of renovascular hypertension with extensive atherosclerotic lesions. We report here on a case of surgical revacularization for medically Intractable atherosclerotic renovascular hypertension together with left common iliac artery occlusion.

Comparison of Repair and Replacement for Mitral Valve Regurgitation (승모판막폐쇄부전에 대한 외과적 치료: 승모판막재건술과 승모판막치환술의 비교)

  • 안지섭;최세영;박남희;유영선;이광숙
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.118-124
    • /
    • 2001
  • 배경: 승모판막재건술이 승모판막치환술보다 술후 좌심실기능이 보다 향상될 수 있으며 또한 수술사망율과 인공판막에 관련된 합병즈인 혈전색전증, 심내막염 및 항응고제사용에 따른 출혈빈도는 낮다고 하였다. 방법: 1996년 1월부터 2000년 5월까지 승모판막폐쇄부전으로 진단된 환자 87례를 대상으로 재건술군 59례, 치환술군 28례로 나누어 비교분석하였다. 결과: 술전 환자들의 NYHA 기능분류, 흉부 X-선상 심흉곽의 비, 심초음파상 좌심실박출계수는 두 군간에 유의한 차이가 없었다. 원인질환은 양군에서 퇴행성 병변이 가장 많았다. 체외순환시간은 재건술군에서 유의하게 길었으나 수술사망은 양군에서 없었다. 술후 NYHA 기능분류, 흉부 X-선상 심흉곽의 비는 향상되었으나 두 군간에 차이가 없었으며 술후 좌심실박출계수는 두 군에서 감소되었으나 유의한 차이는 없었다. 결론: 이상의 결과로 승모판막폐쇄부전에 대하여 재건술이 치환술처럼 비교적 안전하게 시행될 수 있는 술식으로 사료된다.

  • PDF

Effects of Herbicides on Growth and Reproductive Characters of Glycine max (대두(Glycine max)의 생장 및 번식 특성에 미치는 제초제의 영향)

  • Gang, Hye-Sun;Ha, Seung-Hui
    • The Korean Journal of Ecology
    • /
    • v.24 no.3
    • /
    • pp.157-168
    • /
    • 2001
  • Herbicides have been used to control weeds for decades. If detoxification upon exposure to herbicides requires considerable amounts of energy, it could affect the pattern of resource allocation to growth and reproduction of crops. We examined the effects of three levels of a herbicide (Control, Low, and High) on germination, growth and reproductive characters of Glycine max treated twice, i.e., before and after seed germination. Since flowering time of G. max was separated into two groups, flowering time was also considered as a variable in this study. The rate of seed germination tended to be higher at the low level of herbicide compared to other levels. Chlorosis and shape variation of leaves were apparent after the second herbicide treatment, but completely disappeared after six weeks of treatment. The herbicide effects on growth characters were somewhat different between early and late flowering plants, but plants treated with both low and high levels of herbicide reduced their growth compared to those in the control group regardless of flowering time. Plants at the high level of herbicide exhibited the highest growth rate later in the season, suggesting that plants compensated to some extent for reduced growth. However, growth reduction among plants at the high level of herbicide was persistent until the end of growing season. Among plants flowered late in the season, plants in the control level bore a higher number of nodules per plant than those in other levels; such a pattern did not exist among plants flowered early in the season. Plants treated with low and high levels of herbicide produced a lower number of flowers than those in the control. Thus, the herbicide examined affected not only the growth and reproductive characters of non-target crops but also the development and growth of root nodules.

  • PDF

Portal Vein Thrombosis in a Dog with Dirofilariasis (심장사상충에 감염된 개에서 발생한 문정맥혈전증)

  • Yun, Seok-Ju;Cheon, Haeng-Bok;Han, Jae-Ik;Kang, Ji-Houn;Chang, Jin-Hwa;Na, Ki-Jeong;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.600-604
    • /
    • 2010
  • A ten-year-old female mongrel dog was presented to Veterinary Medical Center, Chungbuk National University with the signs of anorexia, weakness, and hemoglobinuria. Patient had been diagnosed as dirofilariasis based on heartworm antigen test and treated with adulticide (melarsomine) at local hospital one day before admission. On laboratory examinations, there were hypochromic and microcytic regenerative anemia, thrombocytopenia, moderate neutrophilia, and increase ALT, AST, and ALP. Radiographic exam showed main pulmonary artery bulging, pulmonary infiltration and hypervascularity, reduced abdominal serosal detail and mild hepatomegaly. Abdominal ultrasonographic exam showed mild peritoneal effusion and large hyperechoic thrombi at trifurcation of the porta hepatica and the splenic vein. In addition, intraluminal low density area and intravascular filling defect were confirmed on contrast enhanced CT scanning at the same anatomic locations. Patient was treated with anticoagulant and thrombolytic therapy. On day 42 after treatment, complete resolution of thrombi was confirmed via ultrasonography and improvement of clinical signs was observed.