• 제목/요약/키워드: 합류식 하수관로 시스템

검색결과 6건 처리시간 0.018초

하수관로정비 지역의 분류식과 합류식 하수관로의 침입율 비교 (Comparison of infiltation rate for separate sewer system and combined sewer system in sewer maintenance areas)

  • 구광모;저소웅;임봉수
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.191-200
    • /
    • 2020
  • This study is to improve the efficiency of BTL (Build Transfer Lease) project operation by comparing the infiltration rate based on the data of 5 years of infiltration of the separate sewer system and combined sewer system. In the survey site, the separate sewer system area consists of eight flowmeters in seven treatment basins, and the combined sewer system area consists of eight flowmeters in five treatment basins. The infillration rate was analyzed by night-time domestic flow evaluation method, and the average infiltration rates of the separate sewer system and combined sewer system were 13% and 16%, respectively. Combined sewer system was about 1.3 times higher than the separate sewer system. The average BOD of separate sewer system was 233 mg/L, which was about 2.4 times higher than the combined sewer system was 107 mg/L. In the comparison of the average pipe diameter-length infiltration of separate sewer system and combined sewer system, the separate sewer system and the combined sewer system were about 0.150 ㎥/d/mm/km and about 0.109 ㎥/d/mm/km, respectively. The floating population in mixed residential and commercial areas has been identified as the cause. Therefore, we propose a method to calculate the infiltration rate in consideration of the margin ratio in the area where the night active population is concentrated.

합류식 하수도 지역에 대형 건축물 설계시 정화조 및 전용오수관로의 비용편익분석 사례연구 (A Case Study on Cost-Benefit Analysis of the Septic Tank and Exclusive Sewage Pipe Line in Designing the large Building at Combined Sewer District)

  • 오현택;김성태;임병인;강병준;박규홍
    • 디지털융복합연구
    • /
    • 제17권6호
    • /
    • pp.169-175
    • /
    • 2019
  • 본 연구의 목적은 합류식 하수처리구역 내에 대형 건축물을 건설하는 경우, 정화조를 설치하는 대안과 정화조를 대신하여 전용오수관로를 설치하는 대안의 경제성을 비교분석하는 것이다. 이를 위해 우리나라 대표적 대형 건축물인 롯데월드타워의 사례를 들어 두 대안 간의 비용편익분석을 수행하였다. 롯데월드타워 건물에 정화조를 설치하는 대신에 전용오수관로를 설치할 경우, 회수기간은 6.2년, 순현재가치(NPV)는 약 61.7억 원이 발생하며, B/C비율은 1.93인 것으로 나타났다. 이러한 사례분석 결과는 향후 정화조 폐쇄에 대한 정책수립과 대형 건축물 신축 시 전용오수관로 건설에 대한 타당성을 검토할 때 적용할 수 있는 유용한 지침을 제공해 줄 것으로 보인다. 향후에는 원인자부담금과 전용오수관로 관리책임 부담여부, 악취감소에 따른 경제적 효익 등을 비용편익분석에 추가적으로 고려할 필요가 있다.

분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어 (Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO)

  • 백현욱;류재나;김태형;오재일
    • 한국지능시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.722-728
    • /
    • 2012
  • 도심지역의 하수관거 시스템은 우수 수용능력 및 하수 월류 발생 등의 시스템의 한계점을 가지고 있어, 강우시 우수 유출수로 인한 침수저감과 더불어 도시비점오염원의 저감에 모두 대응할 수 있는 저류시설의 도입이 주목받고 시작하였다. 최근 환경부에서는 방재적 우수관리와 더불어 합류식 하수관거 월류수, 분류식 우수관거 유출수 처리를 포함하는 다기능 저류시설을 "하수저류시설"이라 통칭하고, 이의 도입을 적극 추진하고 있는 실정이다. 반면 대규모 단일 저류시설 설치의 경우에는 공간 확보의 문제가 발생할 수 있으며, 이에 대안으로는 중 소규모의 분산형 저류시설 설치 및 운영을 들 수 있다. 본 연구에서는 분산형 저류시설-하수관망 네트워크 시스템의 최적 운용을 위한 모델 예측 제어기법을 제안한다. 이를 위해 첫째로 네트워크 시스템의 각 구성 요소의 수리모델을 제시함으로써 보다 정밀한 하수관망 네트워크의 거동을 모사하고자 한다. 둘째로 제안된 모델을 기반으로 현재의 강우 유입량을 고려하여 각 저류조의 수위, 하수관로의 유입/유출량을 예측하여, 입자군집 최적화 알고리즘을 이용한 모델 예측 제어기법을 바탕으로 주어진 제약조건을 만족하며 상황을 바탕으로 제안된 제어기법의 사용여부에 따른 효과를 비교 분석하고, 이의 타당성을 검증하고자 한다.

우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구 (Criteria for calculation of CSO volume and frequency using rainfall-runoff model)

  • 이건영;나용운;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

생활용수 회귀수량 산정방법의 개선연구 -중랑천 유역을 대상으로- (A Study on Improving Estimation of Recurrence Rate of Public Water -Jungnangcheon Watershed-)

  • 정충길;안소라;조형경;김성준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.509-509
    • /
    • 2015
  • 물 수요관리측면에 대한 정책을 수립하기 위해서는 현재 또는 장래에 대한 용수수급의 정확한 이해를 필요로 한다. 이를 위해서는 용수 수요량 및 공급량뿐만 아니라 여러 산정요소를 필요로 하는데, 그 중 회귀수량은 물이 이용되고 다시 하천으로 회귀되어 이용될 가능성이 있는 수량으로 정의되며, 용수수급 및 용수절약 측면에서 회귀 수량은 중요한 요소라 할 수 있다. 회귀수량 조사는 유역조사 사업 이래, 10년간 생?공용수를 중심으로 미시적, 거시적으로 조사를 시행하였으나, 측정 자료의 신뢰도, 조사방법 및 지점선정 등의 문제로 인하여 조사 성과의 활용성이 매우 낮은 실정이다. 수자원장기종합계획등에서는 수자원관련 계획 수립시 생?공용수의 회귀율을 65 %로 적용하고 있으나, 이는 1970년대 말의 사회적 여건 및 경제적 상황이 반연된 결과로 현재 상황에 적용되기 곤란하다. 따라서, 현재 실정에 맞는 회귀율 산정은 반드시 필요하게 된다. 본 연구에서는 기존 생활용수 회귀수량 산정 연구 한계를 보완하고 유역조사 시행을 위한 개선된 회귀수량을 산정하고자 한다. 본 연구는 서울시 중랑물재생센터 처리구역을 기반으로 중랑천유역을 시험유역으로 선정하였다. 기존 회귀수량 산정방법을 개선하기 위해 시험유역 회귀수량 산정을 위한 가용 자료 분석 및 용수흐름 네트워크 공간분석을 추가로 진행하였다. 가용자료로 시험 유역내 상수공급자료(정수장 공급량, 상수계통도, 유수 및 누수율), 하수처리자료(하수처리구역도, 하수처리계통도, 유입량 및 방류량) 및 기상자료(기상청 지점 및 AWS 강우자료)를 구축하였고 각각의 상수계통도 및 하수처리계통도로부터 용수 흐름 네트워크망을 구축하였다. 상수공급자료로부터 상수계통도 공급지역을 구분하여 월별 유수율에 따른 월별 실 공급량을 산정하였다. 하수처리자료로부터 시험유역에서의 월별하수처리 유입량 및 방류량을 산정하였다. 최종적으로 회귀율(하수처리 방류량/실 공급량)을 산정한 결과 연평균 회귀율은 각각 93.97 %(2011년), 95.02%(2012년)로 과잉 추정 되었으며 7 ~ 9월의 회귀율은 110 ~ 120 %로 유입량을 초과하였다. 이는, 하수처리로 유입되는 유입량의 하수관거는 합류식으로 구축되어 7 ~ 9월에 많은 양의 강우량이 우수관을 통해 하수처리장으로 이송되어 생활용수 이외에 자연적인 공급량으로 인한 것으로 분석되었다. 따라서, 월별 회귀율 산정을 위해서는 불투수층에서의 면적강우량(mm)을 유입량(m3/s)으로 환산된 값을 고려하여 회귀율을 재산정하였다. 그 결과 연평균 회귀율은 각각 78.27 %(2011년), 77.58 %(2012년)로 나타났다.각각의 월별 회귀율도 매우 유사하게 나타났으며 과거 관용적으로 사용된 65 % 회귀율보다 약 12 ~ 13%로 증가하였으며 이는, 하수처리시설 구축 및 처리효율의 증가와 상수처리시설의 관로시설의 개량으로 인한 유수율 및 누수율 감소로 회귀율이 증가한 것으로 판단된다.

  • PDF

장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구 (Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation)

  • 이건영;나용운;류재나;오재일
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.785-794
    • /
    • 2013
  • 합류식하수관로시스템에서 강우시 유출수는 관로내 퇴적물과 지표면 세척효과에 의한 오염물질 등이 혼합되어 하천으로 방류되기 때문에 방류수계에 화학적 물리적 생물학적으로 상당한 문제를 야기하지만, 현재 국내에서는 CSOs의 오염 부하량 관리기준을 결정함에 있어 통일된 방법론이 부재한 실정이다. 이에 따라 본 연구에서는 우수유출모형을 활용한 장기간 CSOs 유량-수질모의를 통하여 CSOs의 오염부하량 저감목표를 설정하고자 한다. 이를 위하여 국내외 CSOs 관리기준을 검토하였으며, 그 결과 연간 총 월류부하량 및 발생빈도를 총 2단계로 구분하여 관리하고, 1단계에서는 60%, 2단계에서는 85%를 저감하는 것을 목표로 설정하였다. 도출된 저감 목표 기준을 대상지역에 적용하여 장기간(최소 10년간)의 CSOs 발생 모의를 바탕으로 분석한 결과, BOD 월류부하량 저감목표는 1단계 1,123 kg, 2단계 2,374 kg이었으며, 목표 달성을 위해 대응해야 할월류량은 1단계 $11,685m^3$, 2단계 $24,701m^3$으로 나타났다.