• Title/Summary/Keyword: 한국표준과학연구원

Search Result 467, Processing Time 0.029 seconds

Development of Speed and Precision in the Mass Measurement of Moving Object (이송 물체의 질령 측정 속도 및 정밀도 향상 모사 연구)

  • Lee, Woo Gab;Chung, Jin Wan;Kim, Kwang Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.136-142
    • /
    • 1994
  • This study presents an algorithm and related techniques which could satisfy the important properties of check weighers and conveyor scales. The algorithm of Recursive Least Squares Regression is described for te weighing system simulated as a dynamic model of the second order. Using the model and the algorithm, model parameters and then the mass being weighed can be determined from the step input. The performance of the algorithm is illustrated in digital simulation. Discussions are extended to the development of fast converging algorithm. It turns out that the algorithm shows several desirable features suitable for microcomputer assisted real-time signal processing, which are high precision and stability in noisy environment.

  • PDF

Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft (회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구)

  • Kim, G.S.;Kang, D.I.;Ahn, B.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF

가스장 이온원 시스템에서 마이크로 채널 플레이트의 잡음 제거 방법

  • Han, Cheol-Su;Park, In-Yong;Jo, Bok-Rae;Park, Chang-Jun;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.422.2-422.2
    • /
    • 2014
  • 가스장 이온원(GFIS: Gas Field Ionization Source)은 전자현미경보다 분해능이 향상된 이온현미경의 광원으로 사용하기 위하여 연구되고 있고, 큰 각전류 밀도, 작은 크기의 가상 이온원 그리고 좁은 에너지 퍼짐을 특징으로 한다. 여러 가지 장점을 가지고 있는 GFIS을 개발하기 위해서는 GFIS에서 발생된 이온빔의 형상을 관찰 것이 매우 중요하며, 이러한 관찰을 위한 시스템에는 주로 마이크로 채널 플레이트 (MCP: Micro Channel Plate)가 사용된다. MCP는 채널내부에 입사한 입자의 에너지에 의해서 생성된 이차전자를 수 천 배에서 수 백 만 배 이상 증폭시켜 형광판에 조사하고 발광시키는 방법으로 작은 신호를 영상으로 관찰 할 수 있도록 한다. MCP의 큰 증폭비는 작은 크기의 신호를 큰 신호로 증폭하여 관찰하는데 용이하여, GFIS 방법으로 생성된 이온빔(이온빔 전류 값은 pA 수준)을 관찰하기에 적합하다. 그러나 MCP를 이용하여도 증폭된 이온빔의 세기가 매우 작기때문에 생성된 이온빔 형상을 정확하게 관찰하기 위해서는 MCP의 형광판을 촬영하는 카메라 노출시간을 길게하여 데이터 수집 시간을 늘려야 하는 문제가 있다. 본 발표에서는 이온빔 형상 관찰에 소요되는 시간을 단축하기 위하여 MCP의 잡음이 GFIS의 이온빔 이미지 관찰에 미치는 영향을 분석하고 이를 제거 방법을 소개한다. 본 연구에서는 GFIS 방출 이온빔의 이미지에 포함된 MCP 잡음 특성을 장(전계)이온현미경 (Field Ion Microscope)실험을 통하여 분석하였고, 디지털 이미지 처리 방법을 이용하여 방출 이온빔 이미지에서 MCP 잡음을 제거하여 방출 이온빔 이미지만 추출할 수 있었다. 본 연구에서 제안한 방법을 GFIS 방출 이온빔 관찰시스템에 적용함으로써 기존 방법에 비해 노출시간을 단축하여 방출 이온빔을 관찰 할 수 있었으며, 노이즈 제거 효과로 향상된 이온빔 형상을 얻을 수 있었다. 본 연구결과의 관찰시간 단축과 향상된 이온빔 형상 획득은 이온현미경 개발에 필수적인 단원자 이온빔을 보다 효율적으로 개발할 수 있으며 디지털 이미지 처리로 GFIS 이온빔 생성을 자동화하는데 응용할 수 있다. 더불어 기존방법에 비해 이미지 획득을 위한 MCP의 노출시간을 단축할 수 있으므로 실험장비 수명 단축 방지 및 관리에 큰 장점이 있다.

  • PDF

Measurement of a Phase Plate Simulates Atmospheric Turbulence Depending on Laser Power (레이저 출력에 따른 난류 모사 위상판 측정)

  • Han-Gyol Oh;Pilseong Kang;Jaehyun Lee;Hyug-Gyo Rhee;Young-Sik Ghim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.99-105
    • /
    • 2023
  • The performance of astronomical telescopes can be negatively affected by atmospheric turbulence. To address this issue, techniques for atmospheric turbulence correction have been developed, requiring the simulation of atmospheric turbulence in the laboratory. The most practical way to simulate atmospheric turbulence is to use a phase plate. When measuring a phase plate that simulates strong turbulence, a Shack-Hartmann wave-front sensor is commonly used. However, the laser power decreases as it passes through the phase plate, potentially leading to a weak laser signal at the sensor. This paper investigates the need to control the laser power when measuring a phase plate that simulates strong atmospheric turbulence, and examines the effects of the laser power on the measured wavefront. For phase plates with relatively high Fried parameter r0, the laser power causes a variation of over 10% in r0. For phase plates with relatively low r0, the laser power causes a variation of less than 5%, which means that the influence of the laser power is negligible for phase plates that simulate strong atmospheric turbulence. Based on the system described in this paper, a phase plate simulating strong atmospheric turbulence can be measured at a laser power of 5 mW or higher. Therefore, controlling the laser's output power is necessary when measuring a phase plate for simulating atmospheric turbulence, especially for phase plates with low r0 values.

Calculation of the ultrasonic radiation force acting on a rigid circular cone and the study on the metrology for the acoustic power measurement (강체원뿔표적에 대한 초음파 방사힘 계산과 음향파워측정모델에 관한 연구)

  • Kyungmin Baik;Jooho Lee;Elmina B. C. Fritzie;Yong Tae Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.335-343
    • /
    • 2024
  • This paper came up with the theoretical modelling of the metrology for the acoustic power using ultrasonic radiation force and showed some theoretical results. In order to do this, a scattering model for a rigid circular cone based upon the Kirchhoff approximation was made, which was followed by the calculation of acoustic power, and then, was converted to the radiation force. From these works, it provided the accuracy and limitation of the conventional method using a circular cone, and the expanded metrology modelling that can be applied to a circular cone with arbitrary apex angle. Using these, this study provided the dependence of the metrology for the acoustic power using ultrasonic radiation force on the frequency and the size of the target. As a result, the correction was yielded in the value of the acoustic power calculated by the suggested International Electrotechnical Commission (IEC) method, which needs to be added when the frequency and the size of the target was considered.