• Title/Summary/Keyword: 한국인정기구 인증

Search Result 14, Processing Time 0.025 seconds

Improvement of Management of Long-Term Care Facilities Through FGI (FGI를 통한 노인장기요양시설 운영 개선 방향에 관한 연구)

  • Park, Sung Won;Lee, Won Jae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.1
    • /
    • pp.587-597
    • /
    • 2019
  • With the rapid aging of the nation's population and the increasing number of elderly people with difficulties in daily life, the elderly care system was implemented for social solidarity. Structural problems in the long-term care system that emerged after the introduction of the system are demanded, and the problem of functional readjustment between nursing hospitals and facilities is raised due to the lack of continuity of care for the elderly by institutional and salary types. In this study, we set up research problems related to personnel, staff, and services to address the problem and conducted FGI. Research has shown that the number of elderly and recognized people in the region, the number of elderly and elderly patients, needs to be reflected in long-term care demand, the direction of appropriate institutional and manpower supply policies, and the establishment of local government goals and plans to strengthen the long-care institutions. It was revealed that non-medical accident arbitration bodies are needed to apply the cost of food insurance, provide programs through links with relevant institutions, and manage the admission smoothly.

진공 측정 기술 개발 동향

  • Sin, Yong-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.3-3
    • /
    • 2010
  • 이번 성원에드워드 학술상 수상자 선정은, 진공기술의 중요성에 공감하고 진공기술 발전을 위한 노력을 독려하자는 진공학회 회원들의 의견을 모아주신 결과로 생각한다. 본 발표에서는 그동안 한국표준과학연구원에서 수행해 온 진공 기술 연구 및 산학연 협력 네트워크 활동을 소개하고자 한다. 진공기술은 진공 환경을 발생시키고 측정 제어하며, 만들어진 진공 환경 안에서 원하는 작업을 할 수 있도록 하는 기술을 말한다. 우리나라의 주력산업인 반도체 및 디스플레이의 경우 그 생산 설비의 1/3이상이 진공 장비이며 진공 공정을 통해 만들어진다. 때문에 우리나라에서는 주력 산업분야나 그 전후방 산업의 경쟁력 강화 측면에서 진공기술 개발 중요성이 아주 크다. 한국표준과학연구원은 국가 대표 측정 기관으로 국가 측정 표준을 확립하고 측정관련 과학기술을 연구개발하며 그 성과를 보급하여 경제발전과 과학기술발전, 그리고 삶의 질 향상에 기여하는 것을 임무로 하고 있다. 우리나라에서 진공 측정 표준에 대한 연구가 본격적으로 시작된 것은 1984년으로 불용 장비로 불하받은 펌프와 챔버, 그리고 차관으로 도입된 Capacitance Diaphragm Gauge 몇 개만으로 시작되었다. 지금은 발전을 거듭하여 초음파 간섭 수은주 압력계를 비롯하여 정적 팽창시스템, 동적 팽창 시스템 등 진공도 범위별 국가 표준기와 리크 표준기를 자체 개발 하여 국가 측정 표준을 확립하고 있다. 우리나라의 진공 표준 및 측정 능력은 국제기구인BIPM에서 실시하는 국가 측정능력 비교시험을 통해 세계 최고 수준으로 인정 받은 바 있으며 교정검사 등을 통해 산학연에 보급되고 있다. 진공 측정 및 표준기술을 토대로, 1999년부터 과학기술부와 산업자원부의 지원을 받아 산학연이 필요로 하는 펌프 계측기 부품 소재 및 공정 특성을 평가하기 위한 장치와 절차를 개발하였다. 이를 이용해 보급되는 기술 data는 진공부품 및 장비 국산화, 국산제품 신뢰성 제고, 검증부품 사용을 통한 장비 품질 향상, 독자적 장비 기술 확보, 생산품 품질관리 등에 쓰이고 있다. 한국 표준연구원 진공센터의 교정 및 시험 능력은 ISO 9001 인증 획득과 국제 전문가의 review를 거쳐, 국제기구 측정능력표에 등재되어 있어 국제적 신뢰도도 확보하고 있다. 정기적인 진공기술 교류회를 개최하고 진공기술 홈페이지를 운영 하는 등 산학연 정보 교류 및 협력 네트워킹 활성화를 위해 노력한 바 있으며 이 분야의 연구 성과는 '국가 우수 연구성과 100선'에 선정된 바 있고, 산업자원부 지정 '산학연 연계 우수사례' 첫 번째로 선정되기도 하였다. 2008년부터는 진공기술 교류회 등을 통한 네트워킹 활동으로 도출된 기술 수요에 따라 대기업과 중소기업 학교 연구소들과 함께 진공공정 실시간 측정 진단 기술과 센서 개발 연구, 그리고 이들 개발품의 신뢰성 검증 및 평가 기술 개발을 위해 노력하고 있다.

  • PDF

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Calibration of δ13C values of CO2 gas with different concentrations in the analysis with Laser Absorption Spectrometry (레이저흡광분석기(Laser Absorption Spectrometry)를 이용한 CO2가스의 탄소안정동위원소비 보정식 산출)

  • Jeong, Taeyang;Woo, Nam C.;Shin, Woo-Jin;Bong, Yeon-Sik;Choi, Seunghyun;Kim, Youn-Tae
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.537-544
    • /
    • 2017
  • Stable carbon isotope ratio of carbon dioxide (${\delta}^{13}C_{CO2}$) is used as an important indicator in the researches for global climate change and carbon capture and sequestration technology. The ${\delta}^{13}C$ value has been usually analyzed with Isotope Ratio Mass Spectrometer (IRMS). Recently, the use of Laser Absorption Spectrometry (LAS) is increasing because of the cost efficiency and field applicability. The purpose of this study was to suggest practical procedures to prepare laboratory reference gases for ${\delta}^{13}C_{CO2}$ analysis using LAS. $CO_2$ gas was adjusted to have the concentrations within the analytical range. Then, the concentration of $CO_2$ was assessed in a lab approved by the Korea Laboratory Accreditation Scheme and the ${\delta}^{13}C_{CO2}$ value was measured by IRMS. When the instrument ran over 12 hours, the ${\delta}^{13}C$ values were drifted up to ${\pm}10$‰ if the concentration of $CO_2$ was shifted up to 1.0% of relative standard deviation. Therefore, periodical investigation of analytical suitability and correction should be conducted. Because ${\delta}^{13}C_{CO2}$ showed the dependency on $CO_2$ concentration, we suggested the equation for calibrating the concentration effect. After calibration, ${\delta}^{13}C_{CO2}$ was well matched with the result of IRMS within ${\pm}0.52$‰.