• Title/Summary/Keyword: 한국의 방사선치료

Search Result 1,037, Processing Time 0.027 seconds

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

사이버나이프의 Targeting 에러의 평가

  • Jang, Ji-Seon;Gang, Yeong-Nam;Lee, Tae-Gyu;Choe, Byeong-Ok;Lee, Gyeong-Jin;Choe, Il-Bong;Kim, Mun-Chan;Gwon, Su-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.87-88
    • /
    • 2005
  • 사이버나이프를 이용한 두경부와 체부 등의 정위방사선수술에서는 목표점의 식별 및 위치 추적에 대하여 높은 정확성을 요구한다. 본 연구에서는 사이버나이프의 targeting의 정확성을 평가하고자 한다. 사이버나이프의 targeting의 정확성을 평가하기 위하여 두상 팬텀을 사용하였다. 환자 치료시와 동일한 CT 영상 프로토콜로 두상 팬텀의 영상을 얻어 치료계획을 세웠다. 팬텀에 radiochromic 필름을 삽입한 뒤 수립된 치료계획에 맞춰 팬텀에 방사선을 조사하였다. 방사선 조사시 위치 추적은 skull과 fiducial 추적의 두 가지 방법을 사용하였다. 방사선에 조사된 radiochromic 필름을 분석하여 정확성을 평가하였다. 본 연구를 통하여 실시간 영상유도 기술을 사용하는 사이버나이프는 약 1 mm의 targeting 에러를 보였다.

  • PDF

Missing tissue compensator modeling using a digital image technique in Radiation Therapy (디지털 영상을 이용한 방사선치료용 결손조직보상체 모델링)

  • Kim, Yonng-Bum;Choi, O-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.907-910
    • /
    • 2005
  • 방사선치료에서 결손조직의 보호를 위해 사용되는 기존의 결손조직 보상체는 체표윤곽을 얻기위해 컴퓨터단층촬영영상이나 자기공명촬영영상등의 의료영상을 이용해 왔다. 하지만 이러한 촬영을 위해서는 고가의 비용이 소요되고 방사선치료에 따른 체표윤곽의 변화에 적절히 대응하지 못하는 등의 단점이 지적되고 있다. 따라서 본 연구에서는 사용이 간편한 디지털 카메라로 환자를 촬영한 후 얻은 2차원 이미지를 이용하여 결손조직 보상체를 제작하고 이의 유용성 평가를 위해 기하학적, 선량학적 평가를 수행하였다. 그 결과, 조직결손을 보정하고 정상조직을 보호할 수 있어 임상적용의 가능성을 확인 할 수 있었다.

  • PDF

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

Evaluation of Lead Oxide Dosimeter for Quality Assurance of Electron Beam in Radiotherapy (방사선치료 전자선의 정도관리를 위한 Lead Oxide 선량계 평가)

  • Yang, Seungwoo;Han, Moojae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.79-83
    • /
    • 2021
  • In radiation therapy, electron beam is often used in the treatment of superficial lesion. Accurate measurements are required because electron beam interacts with them in the beam path and affects dose measurements. However, no research has been conducted on electron beam quality assurance. in this study, PbO-based dosimeter was fabricated as a basic study for electron beam quality assurance. Thus, the reproducibility and linearity of the energy of 6, 9, and 12 MeV were analyzed to evaluate measurement accuracy and precision. Reproducibility measurements show RSD value of 1.024%, 1.019% and 0.890%, respectively, at 6, 9, and 12 MeV. linearity measurements show 0.9999 R2 at 6, 9, and 12 MeV altogether. Both evaluations show that the PbO dosimeter has very good measurement accuracy and precision with excellent results.

Postoperative Complications after Preoperative Chemoradiotherapy Combined with Hyperthermia in Locally Advanced Rectal Cancer (국소 진행성 직장암의 수술전 동시 화학방사선치료와 온열치료병합시 수술후 부작용)

  • Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • We investigated whether regional hyperthermia (HT) increased post-surgical complications in patients with locally advanced rectal cancer treated with preoperative concurrent chemoradiotherapy (CCRT). Between 1996 and 2007, 205 patients treated with preoperative CCRT and curative surgery were evaluable for the analysis of acute and late toxicities. A total dose of 39.6 Gy or 45 Gy was delivered concurrently with one or two cycles of chemotherapy (5-fluorouracil, leucovorin). Eighty-eight patients received regional HT twice a week using an 8-MHz radiofrequency capacitive heating device. Surgery was performed 4~6 weeks after the completion of preoperative CCRT. The median age was 59 years (range, 18~83) and the median follow-up period was 61months (range, 2~191). The 5-year overall survival and complication-free survival rate of all patients was 77.4% and 73.7%, respectively. Early leakage, delayed leakage, anastomotic stricture, fistula, and small bowel obstruction occurred in 1.0%, 2.9%, 1.5%, 5.9%, and 17.1%, respectively. HT did not increase all kinds of complications. The 5-year complication-free survival rate was 71.8% in the non-HT group and 76.3% in the HT group (p=0.293). Regional HT did not increase postoperative complications in patients with locally advanced rectal cancer treated with preoperative CCRT followed by curative surgery.

A Study of Cancer Incidence Rate due to Photoneutron Dose during Radiation Therapy for Prostate Cancer Patients (전립샘암 환자의 방사선 치료 시 광중성자 선량으로 인한 암 발생률의 연구)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.471-476
    • /
    • 2022
  • The purpose of this study was to study the probability of cancer occurrence due to photoneutron dose exposure of the colon and thyroid gland, which are normal organs, in 3D CRT, IMRT 5 portals, and IMRT 9 portals, which are radiotherapy methods for prostate cancer. The total prescribed dose for prostate cancer was 6600 cGy, 220 cGy per dose, and 30 divided irradiations were applied for the total number of times. After setting up the Rando phantom on the treatment table (couch) of the medical linear accelerator used in the experiment, an optically stimulated luminescence albedo neutron dosimeter was placed on the corresponding area of the large intestine and thyroid gland of the phantom for measurement. During 3D CRT of prostate cancer, the probability of secondary cancer due to photoneutron dose to the colon and thyroid gland, which are normal organs, was 1.8 per 10,000 people. And IMRT 5 portals were 8.7 per 10,000 people, which was about 5 times larger than 3D CRT. IMRT 9 portals derived the result that there is a probability that 1.2 people per 1,000 people will develop cancer. Based on this study, the risk of secondary radiation exposure due to the dose of photoneutrons generated during radiation therapy is studied, and it is thought that it will be used as useful data for radiation protection in relation to the stochastic effect of radiation in the future.