• Title/Summary/Keyword: 한국병원

Search Result 11,437, Processing Time 0.046 seconds

ERUPTION TIME AND SEQUENCE OF PERMANENT TEETH IN STUDENTS FROM E-ELEMENTARY SCHOOL (E-초등학교 어린이의 영구치 맹출시기 및 순서)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Lee, Jae-Ho;Kim, Seong-Oh;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.253-261
    • /
    • 2009
  • The purpose of this study was to present new data on the timing and sequence of permanent teeth emergence and to compare these findings with the results of earlier studies. The dental examinations had been performed to E-elementary school students, who visited the Yonsei University Dental Hospital between 1998 and 2005; 1,307 boys and 1,312 girls with the age ranging from 6 to 12 years old. The followings were concluded. 1. Eruption time of the maxillary permanent teeth is as follows. It was 6.81 years in male and 6.73 years in female for the central incisor, 7.78 years in male and 7.65 years in female for the lateral incisor, 10.48 years in male and 9.92 years in female for the canine, 9.76 years in male and 9.63 years in female for the first premolar, 10.66 years in male and 10.49 years in female for the second premolar, 6.39 years in male and 6.26 years in female for the first permanent molar, and 12.13 years in male and 12.03 years in female for the second permanent molar. 2. Eruption time of the mandibular permanent teeth is as follows. The central incisor could not be determined in this study, but it is assumed to erupt before the age of 6.08. In the mandible, eruption time was 6.78 years in male and 6.65 years in female for the lateral incisor, 9.76 years in male and 9.05 years in female for the canine, 9.82 years in male and 9.59 years in female for the first premolar, 10.67 years in male and 10.52 years in female for the second premolar, 6.22 years in male and 6.12 years in female for the first permanent molar, and 11.58 years in male and 11.14 years in female for the second permanent molar. 3. The eruption sequence is as follows. In the maxilla, the first permanent molar erupted first, followed by the central incisor, the lateral incisor, the first premolar, the canine, the second premolar, and the second permanent molar. In the mandible, the central incisor erupted first, followed by the first permanent molar, the lateral incisor, the canine, the first premolar, the second premolar, and the second permanent molar. 4. Tooth eruption occurred earlier in female compared to male by average of 0.19 year in the maxilla and 0.29 year in the mandible. 5. In both male and female, the hiatus (interval of rest) occurred between the emergence of lateral incisor and first premolar in the maxilla while it was observed between the lateral incisor and canine in the mandible. Male had a hiatus of 1.98 years in the maxilla and 2.90 years in the mandible, while the female's were 1.98 years and 2.40 years, respectively.

  • PDF

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

Detection and Control of Bacterial Diseases of Cultured Fishes in Korea (양식어류(養殖魚類)의 세균성질병(細菌性疾病)의 진단(診斷)과 대책(對策))

  • Chun, Seh-Kyu
    • Journal of fish pathology
    • /
    • v.1 no.1
    • /
    • pp.5-30
    • /
    • 1988
  • This is a comprehensive study for considering the effective treatment and control program of bacterial disease occurring in common carp, israel carp, color carp, crucian carp, eel and tilapia by clarifying the causes, mechanism of infection and onset and the diagnostic criteria. As a first step, the authors investigated the external views, gross and histopathologic findings of diseased fish using 450 infected fishes obtained from various farmer of Korea. This infection was characterized by hyperemia, hemorrhage and swelling of body surface and fins, congestion of liver, spleen, kidney, inflammation of intestine, hemorrhagic inflammation of various tissues, and necrosis and ulcer of various tissues were accompanied in serious cases. Bacteriologically, Aeromonas hydrophila and Edwardsiella tarda were isoiated from these fishes. Particularly in the regular check on 222 eels, 177 strains were isolated as 29.94% of Aeromonas hydrophila, 48.58% of Edwardsiella tarda and 21.47% of Flexibacter columnaris. Hexibacter columnaris was isolated from corroded gill of eels. The identical disease was occurred by innoculating the isolated Aeromonas hydrophila and Edwardsiella tarda and the identical strains were isolated from infected experimental fishes. The eels which were diagnosed Aeromonas disease from Kwangju, Pusan accompanied hemorrhage, swelling of body surface and fins, inflammation of stomach and intestine containing mucous fluids mixed with the pathogens. Color carp and crucian carp which were innoculated with the isolated 5 strins of Aeromomas hydrorphil died within 3 or 4 days accompanying with the characteristics of Aeromonas disease. Edward disease was characterized by abscesses of body surface, pus formation with concentration on phagocytes. The size of absecsses increased with progression elf disease. There were also various abscesses at internal organ and white nodules appeared in kidney. Histologically, various progressive granuloma were examined without inflammation of intestine. Columnaris disease of eels showed no hemorrhage except slight white body color. In autopsy, most of internal organs appeared normal and there were no septic odors. The only character was corrosion of gills. In order to treat these bacterial diseases, infected fishes must bathe in 20ppm chloramphenicol or kanamycin solution for 1 hour. Besides, medication program in oral ingestion of 75mg/kg chloramphenicol per day continuing for 5 to 7 days. After injecting the formalin treated Aermonas hydrophila antigen into carp, relatively high agglutination titer showed between 3 weeks and 6 weeks. Though this titer decreased from that time, it was continued for 18 weeks. In the case of injecting the formalin treated Edwardsiella tarda antigen into tilapia, the titer also increased. But tilapia which were immersed in the suspension fluid of the formalin treated Edwardsiella tarda showed no increase of the titer.

  • PDF

A Study on Influence of Foodservice Managers' Emotional Intelligence on Job Attitude and Organizational Performance (급식관리자의 개인적 감성지능이 직무태도 및 조직성과에 미치는 영향)

  • Jung, Hyun-Young;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1880-1892
    • /
    • 2010
  • The purposes of this study were to: a) provide evidence concerning the effects of emotional intelligence on job outcomes, b) examine the impacts of emotional intelligence on employee-related variables such as 'job satisfaction', 'organizational commitment', 'organizational performance', and 'turnover intention' c) identify the conceptual framework underlying emotional intelligence. A survey was conducted to collect data from foodservice managers (N=231). Statistical analyses were completed using SPSS Win (16.0) for descriptive analysis, reliability analysis, factor analysis, t-test, correlation analysis, cluster analysis and AMOS (16.0) for confirmatory factor analysis and structural equation modeling. The concept of emotional intelligence (EI) has been on the radar screens of many leaders and managers over the last several decades. The emotional intelligence is generally accepted to be a combination of emotional and interpersonal competencies that influence behavior, thinking and interaction with others. The main results of this study were as follows. The four EI (Emotional Intelligence) dimensions correlated significantly with age. The means of job satisfaction score were above the midpoint (3.04 point) scale. The organizational commitment score was above the midpoint (3.41 point) scale and was higher at 'loyalty' factor than 'commitment' factor. The means of organizational performance score were above the midpoint (3.34) scale. The correlations among the four EI (emotional intelligence) factors were significant with job satisfaction; organizational commitment, organizational performance and turnover intention. The test of hypothesis using structural equation modeling found that emotional intelligence produced positive effects on job attitude and job performance. Emotional intelligence enhanced organizational commitment, and in turn, managers' attitude produced positive effects on organizational performance; emotional intelligence also had a direct impact on organizational performance. This study has identified the effect of emotional intelligence on organizational performance and attitudes toward one's job.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

The Histologic Type of Lung Cancer in Idiopathic Pulmonary Fibrosis : the Difference According to the Presence of Fibrosis at Cancer Location (특발성 폐섬유화증에서 발생한 폐암의 조직형의 특성 : 폐암 위치의 섬유화 유무에 따른 조직형의 차이)

  • Kwon, Sung-Youn;Kim, Deog-Kyeom;Lee, Suk-Young;Yoo, Chul-Gyu;Lee, Choon-Taek;Kim, Young-Whan;Im, Jung-Gi;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.441-452
    • /
    • 2000
  • Background : It is well known that the prevalence of lung cancer is higher in idiopathic pulmonary fibrosis (IPF) patients than in the general population. This high prevalence is explained by the concept of 'scar carcinoma'. There have been several reports on the prevalence of histologic typo of lung cancer in IPF with conflicting results. Despite of the high smoker rate in almost all previous reports, none considered the smoking history of patients. Therefore we performed a separate studies on fibrosis associated lung cancer and smoking associated lung cancer. The purpose of this study is to investigate the proportion of lung cancer in IPF that is fibrosis associated and to determine the most common histologic type in fibrosis associated lung cancer in IPF. Method : A retrospective review of medical records and radiologic studies was performed for cases of lung cancer with IPF. We investigated smoking history, sequence of diagnosis of lung cancer and IPF, histologic type of lung cancer and the cancer location, especially whether the location is associated with fibrosis. To evaluate the proportion of fibrous associated lung cancer, the lung cancer in IPF were categorized according to the presence of fibrosis at cancer location. Results : Fifty seven patients were subjects for this analysis. Six (11%) cases were diagnosed as lung cancer during follow-up for IPF, and both diseases were diagnosed simultaneously in the others. Ninety four percent of patients were smokers and the average smoking amount was 47.1$\pm$21.9 pack-year. Among the patients with IPF and lung cancer, 42(80.8%) cases were considered as "fibrosis associated". The remainder was "not fibrosis associated" and probably was due to smoking etc. Although the most frequent histologic type was squamous cell carcinoma as a whole, adenocarcinoma was the prominent histologic type in "fibrosis associated lung cancer." Conclusion : Considering the proportion of "fibrosis not associated lung cancer" in the patients with IPF and lung cancer, significant proportion of lung cancer in IPF may not be fibrosis induced. This may influence the distribution of histologic type of lung cancer in IPF.

  • PDF

A Study on Synergisitic Effect of Chitosan and Sorbic Acid on Growth Inhibition of Escherichia coli O517:H7 and Staphylococcus aureus (E. coli O517:H7 과 Staphylococcus aureus의 증식억제에 대한 키토산과 소르빈산의 상승효과에 관한 연구)

  • 조성범;이용욱;김정현
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.2
    • /
    • pp.112-120
    • /
    • 1998
  • This study was performed to investigate the synergistic effect of chitosan and sorbic acid as a new food preservative. So it was performed to investigate inhibitory effect on growh of E. coli 0157:H7, gram negative pathogenic food borne disease bacteria and of S. aureus, gram positive food borne disease bacteria in chitosan, sorbic acid and combination of chitosan and sorbic acid. Minimun Inhibitory Concentration (MIC) of chitosan in E. coli 0157:H7 was 500 ppm at pH 5.0, 250 ppm at pH 5.5, 500 ppm at pH 6.0, and 2000 ppm at pH 6.5, while in Staph. aureus 31.25 ppm at pH 5.0 and 62. 5 ppm at more than pH 5.5. also, MIC of sorbic acid in E. coli 0157:H7 was 500 ppm at pH 5.0, 1500 ppm at pH 5.5, and 2000 ppm at more than pH 6.0, while in Staph. aureus 1500 ppm at pH 5.0 and more than 2000 ppm at more than pH 5.5. Due to the effect of pH in E. coli 0157:H7, MIC of combined chitosan and sorbic acid was 500 ppm of chitosan with 500 ppm of sorbic acid at pH 6.5, but 250 ppm of chitosan with 31.3 ppm of sorbic acid at pH 5.0. In Staph. aureus, there was great effect of chitosan, but neither effect of pH nor sorbic acid. When E. coli 0157:H7 were treated with 500 ppm of chitosan with 500 ppm of sorbic acid and 250 ppm of chitosan with 250 ppm of sorbic acid at pH 6.5, they were inhibited. But, they were increased at the initial concentration of bacteria at 1000 ppm of chitosan in 18 hours, at 500 ppm of chitosan in 36 hours. There was no effect of growth inhibition with sorbic acid but great effect with chitosan on Staph. aureus. The correl~tions between MICs of chitosan and sorbic acid in E. coli 0157:H7 accoding to pH were higher than those in Staph. aureus. R values in E. coli 0157:H7 were 0.95 (p<0.01), 0.99 (p<0.01), 0.97 (p<0.01), and 0.99 (p<0.01) at pH 6.5, 6.0, 5.5, and 5.0 respectively. The synergistic effect of chitosan and sorbic acid in E. coli 0157:H7 could be confirmed from the result of this experiment. Therefore, it was expected that the food preservation would increase or maintain by using sorble acid together with chitosan, natural food additive that did no harm to human body.

  • PDF

Clinical Differential Diagnosis of Usual Interstitial Pneumonia from Nonspecific Interstitial Pneumonia (통상성 간질성 폐렴과 비특이성 간질성 폐렴의 임상적 감별 진단)

  • An, Chang-Hyeok;Koh, Young-Min;Chung, Man-Pyo;Suh, Gee-Young;Kang, Soo-Jung;Kang, Kyeong-Woo;Ahn, Jong-Woon;Lim, Si-Young;Kim, Ho-Joong;Han, Jeung-Ho;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.932-943
    • /
    • 2000
  • Background : Nonspecific interstitial pneumonitis (NSIP) is most likely to be confused with usual interstitial pneumonitis (UIP). Unlike patients witþ UIP, the majority of patients with NSIP have a good prognosis, with most patients improving after treatment with corticosteroids. Therefore it is clinically important to differentiate NSIP from UIP. Up to now, the only means of differentiating these two diseases was by means of surgical lung biopsy. American Thoracic Society (ATS) proposed a clinical diagnostic criteria for UIP to provide assistance to clinicians in its diagnosis without surgical lung biopsy. This study is aimed to investigate whether there were clinical and radiological differences between NSIP and UIP, and the usefulness of ATS clinical diagnostic criteria for UIP in Korea. Methods : We studied 60 patients with UIP and NSIP confirmed by surgical lung biopsy. Clinical manifestations, pulmonary function test, arterial blood gas analysis, bronchoalveolar lavage (BAL), and high resolution computed tomography (HRCT) were evaluated and analyzed by Chi-square test or t-test. The clinical criteria for UIP proposed by ATS were applied to all patients with idiopathic interstitial pneumonia. Results : Forty-two patients with UIP and 18 with NSIP were pathologically identified. Among the 18 patients with NSIP (M : F=1 : 17), the mean age was 55.2$\pm$8.4 (44~73) yr. Among the 42 patients with UIP (M : F=33 : 9), the mean age was 59.5$\pm$7.1 (45~74) yr (p=0.046). Fever was more frequent in NSIP (39%) (p=0.034), but clubbing was frequently observed in UIP (33%) (p=0.023). BAL lymphocytosis was more frequent (23%) (p=0.0001) and CD4/CD8 ratio was lower in NSIP (p=0.045). On HRCT, UIP frequently showed honeycomb appearance (36 of 42 patients) though not in NSIP (p=0.0001). Six of 42 UIP patients (14.3%) met the ATS clinical criteria for IPF, and 3 of 16 NSIP patients (18.8%) met the diagnostic criteria. Conclusion : Being a relatively young female and having short duration of illness, fever, BAL lymphocytosis, low CD4/CD8 ratio with the absence of clubbing and honeycomb appearance in HRCT increase the likelihood of the illness being NSIP. The usefulness of ATS clinical diagnostic criteria for UIP may be low in Korea.

  • PDF