• Title/Summary/Keyword: 한계온도

Search Result 887, Processing Time 0.025 seconds

알코올화합물의 폭발특성 및 화염온도 예측에 관한 연구

  • 하동명
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.179-184
    • /
    • 1998
  • 가연성물질의 안전한 취급을 위해서는 이들 물질의 가장 기초적인 위험 특성 자료인 폭발한계(화재안전자료)에 대한 지식을 필요로 한다. 발화원이 존재할 때 가연성가스와 공기가 혼합하여 일정 농도 범위내에서만 연소가 이루어지는데 이 혼합범위를 폭발(연소)한계(explosive(flammable) limits) 또는 연소범위라 한다. (중략)

  • PDF

A Study on Measurements of Autoignition and Activation Energy of Superabsorbent Polymers (고흡수성 중합체의 자연발화와 활성화에너지 측정에 관한 연구)

  • Jong-Man Heo;Jae-Wook Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.292-304
    • /
    • 2023
  • Purpose: This study was conducted to obtain experimental data for the establishment of preventive measures against fire, as large and small fire accidents occur at production and storage sites of superabsorbent polymers developed for the convenience of daily life. Method: The sample container was fixed at 0.2m in both length and width, and was shaped into a rectangular cuboid with heights of 3cm, 5cm, 7cm, and 14cm to access an infinite flat plane. The sample container was fixed in the center of a thermostatic bath that was heated to a predetermined temperature according to a preset temperature control program. If the central temperature of the sample rose more than 20℃ above the set temperature, it was determined to have 'ignited', and if it remained similar to the set temperature, it was determined to have 'unignited'. Result: The critical autoignition temperature was calculated to be 212.5℃ for a sample container with a height of 3cm, 202.5℃ for 5cm, 192.5℃ for 7cm, and 177.5℃ for 14cm. The ignition induction time to reach the highest temperature was approximately 42hours for 3cm, 91hours for 5cm, 151hours for 7cm, and 300hours for 14cm. Conclusion:① As the size of the sample container increased, the autoignition temperature decreased and the ignition induction time to reach the highest temperature increased. ② The apparent activation energy was calculated to be 39.30kcal/mol, with a correlation of 99.5%.

A Prediction Method of Temperature Distribution on the Wafer in a Rapid Thermal Prossing System with Multipoint Sensing (고속 열처리 공정 시스템에서 웨이퍼 상의 다중점 계측에 의한 온도분포 추정 기법 연구)

  • Shim, Yeung-Tae;Koo, Jin-Mo;Kim, Hag-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.618-620
    • /
    • 1999
  • 웨이퍼내의 온도 균일도를 확보하는 것은 고속열처리공정장비(RTP)에 있어서 입력신호 수집을 통해 달성해야 할 중요한 제어 요소이며, 이러한 온도의 균일도를 향상시키기 위해서는 웨이퍼의 각 지점에 대한 정확한 온도 계측이 필수적으로 선행되어야 한다. 그러나 RTP의 구조적 특징과 동작특성 때문에 정확한 온도계측이 매우 어려운 면이 있다. 온도계측은 주로 고온계를 통해 이루어지는데 대류와 복사 등 여러 가지 원인에 의해서 웨이퍼내에 온도가 불균일하게 되는 경우 한정된 개수의 고온계로 온도 분포를 정확히 추정할 수 없는 한계를 지니고 있다. 본 논문에서는 RTP 공정을 열역학적으로 접근하여 단일점 온도 계측에 의한 전체 온도 분포 추정 기법을 연구하고 이것을 다중점 온도 계측에 의한 온도 분포 추정 기법으로 확장 발전시켜 웨이퍼에 상대적으로 영향을 끼치는 요소 중 예측 불가능하거나 측정 불가능한 요소까지 포함하여 최소의 측정치를 활용하여, 적절한 제어입력 유도에 필요한 형태로 웨이퍼상의 온도계측을 가능하게 하였다.

  • PDF

Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load (재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정)

  • Yoon, Sung Kee;Lee, Chy Hyoung;Koo, Bon Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • The domestic fire resistance performance test is conducted as a prescriptive design method such as quality test. In quality test there are 2 methods, unloaded fire resistance test and fire resistance test under load. In realistic, these tests, however, have problems with expense, time and diversity of structure. This study reviewed fire resistance performance of H-beam flexural member by thermal stress analysis using finite element ABAQUS program. This research is for the performance-based design reviewing applicability of domestic standard. As a result of this study, limit temperatures per each load ratio provied for proper performance of fire resistancy.

양론계수와 연소열을 이용한 Ether류의 폭발하한계 예측

  • 하동명;최용찬;이성진;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.428-433
    • /
    • 2003
  • 화재 및 폭발 특성치로 인화점, 최소발화온도, 폭발한계, 최소발화에너지, 연소열 등을 들 수 있다. 연소특성은 인화성용제들(석유류 및 알코올류 등)의 취급, 저장, 수송에서 포함되어 있는 잠재 위험성을 평가할 때 고려된다. 여러 연소특성 가운데 폭발한계(explosive limits)는 가연성물질(가스 및 증기)을 다루는 공정 설계 시 고려해야 할 중요한 변수로써, 발화원이 존재할 때 가연성가스와 공기가 혼합하여 일정 농도범위 내에서만 연소가 이루어지는 혼합범위를 말한다.(중략)

  • PDF

The Relationships Between Soil Moisture and Soil Temperature at Selmacheon Tower in Season (설마천 타워에서의 계절적 변화를 고려한 지중온도와 토양수분의 관계)

  • Jin, Ji-Ung;Joo, Je-Young;Choi, Min-Ha;Lee, Seung-Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.91.2-91.2
    • /
    • 2010
  • 지면-대기상의 관계에서 지중온도와 토양수분의 역할이 중요함에도 불구하고 이들 변수의 다양한 시공간적 변동성, 관측자료의 한계, 관련자료 및 이해 부족 등으로 인하여 아직까지 체계적인 연구가 이루어지지 못하고 있다. Idso 등(1975)에 의해 처음 토양수분과 지중온도에 대한 연구를 시작으로 Lakshmi 등(2003)은 지중온도가 토양수분과 역의 관계를 가짐을 도출하였으며 이를 이용한 선형회귀분석을 수행하여 토양수분을 예측하였다. 기존연구를 바탕으로 본 연구에서는 설마천 타워(Flux tower)에서 기록된 지중온도와 토양수분 자료를 이용하여 사계절에 따른 상관관계를 분석하였다. 조사기간 동안 토양수분은 봄부터 가을까지의 경우 지중온도가 강한 음의 상관계수를 가지는 반면 겨울의 경우 지중온도와 강한 양의 상관계수를 가지는 것으로 판단이 되었다. 즉, 계절에 따라 지중온도와 토양수분의 관계가 차이가 있음을 알 수 있다. 또한, 본 연구에서 토양수분에 대한 지중온도의 계절별 선형적 관계를 도출하였으며 지표상의 물 에너지 순환에 대한 보다 나은 이해를 줄 것으로 사료된다.

  • PDF

The Measurement and Prediction of the Fire and Explosion Properties of Isoamyl alcohol (이소아밀알코올의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.34-40
    • /
    • 2016
  • For the safe handling of isoamyl alcohol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of isoamyl alcohol was experimented. And, the lower explosion limit of isoamyl alcohol was calculated by using the lower flash point obtained in the experiment. The flash points of isoamyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $31^{\circ}C$ and $33^{\circ}C$, respectively. The flash points of isoamyl alcohol by using the Tag and Cleveland open cup testers are measured $43^{\circ}C$and $45^{\circ}C$. The AIT of isoamyl alcohol by ASTM 659E tester was measured as $419^{\circ}C$. The lower explosion limit by the measured flash point $31^{\circ}C$ was calculated as 0.87 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Temperature Data-Based Assessment of the Marginal Heading Dates and the Growth Duration of Rice in the Regions of North Korea (북한 지역의 기온 자료를 활용한 벼 출수 한계기 및 재배 기간 분석)

  • Yang, Woonho;Kang, Shingu;Kim, Sukjin;Choi, Jong-Seo;Park, Jeong-Hwa
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.284-295
    • /
    • 2018
  • The safe and late marginal heading dates (SMHD, LMHD), cropping probability, and growth duration of rice were assessed using temperature data in the 27 regions of North Korea. The medians of SMHD and LMHD ranged Jul. 16 and Jul. 27 in Hyesan to Aug. 18 and Aug. 28 in Haeju, respectively, except Changjin, Pungsan, and Samjiyon that did not show any of the SMHD and LMHD. The medians of the days from early marginal transplanting date (EMTD) to heading date ranged 51 days in Hyesan to 109 days in Pyongyang for SMHD and those were delayed by 9~15 days for LMHD, compared to SMHD. Nineteen regions (Kaesong, Haeju, Yongyon, Singye, Sariwon, Nampo, Pyongyang, Anju, Kusong, Sinuiju, Changjon, Wonsan, Hamhung, Pyonggang, Yangdok, Huichon, Supung, Sinpo, Kanggye) and additional four regions (Kimchaek, Chongjin, Sonbong, Chunggang) had the rice cropping probability higher than 80% when analyzed based on the SMHD and LMHD, respectively. The representative SMHD ranged Jul. 24 for Pyonggang to Aug. 12 for Haeju. Compared to the days from EMTD to SMHD, those from EMTD to LMHD were delayed by 9~17 days. When applied SMHD, thirteen regions (Yangdok, Kanggye, Huichon, Supung, Yongyon, Kusong, Anju, Sinuiju, Singye, Pyongyang, Kaesong, Nampo, Sariwon) had the appropriate range of cumulative temperature during grain filling (CT) for grain yield and quality. Sinpo, Hamhung, Pyonggang, Wonsan, Changjon, and Haeju had the CT higher than $1,300^{\circ}C$. It is supposed that rice cropping could be extended to the regions where LMHD-applied cropping probability was higher than 80%. Delaying the heading date than SMHD could be also considered in the regions where the days to SMHD is small but CT is large.

Fabrication of low power micro-heater based on electrochemically prepared anodic porous alumnia (다공성 알루미늄 산화물을 이용한 저전력 마이크로 히터의 제조)

  • Park, Seung-Ho;Byeon, Seong-Hyeon;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.116.1-116.1
    • /
    • 2016
  • 반도체 가스센서에서는 가연성 및 탄화수소계 가스를 감지 하기 위해서 $100{\sim}500^{\circ}C$ 이상의 동작온도를 필요로 한며, 이에 따라 반도체식 가스센서의 마이크로 히터 소재는 고온에서 열적 안정성이 있는 소재가 요구된다. 현재 상용화되고 있는 반도체식 가스센서는 실리콘(Silicon) 기반의 MEMS 기술을 이용한 가스센서이며, 구조적으로나 성능적 한계가 드러남에 따라 실리콘 이외의 다양한 재료의 MEMS 응용기술 개발이 필요한 실정이다. 본 연구에서는 이러한 실리콘의 재료적 한계를 극복하기 위해 다공성 알루미늄 산화물(AAO)을 기판으로 사용하여 마이크로 히터를 제작하였다. AAO의 제작에 앞서 CMP, 화학연마, 전해연마를 이용하여 적합한 전처리 공정을 선정하였고, AAO 제작 시 온도, 시간, 전압의 변수를 주어 마이크로 히터 기판에 적합한 공정을 탐색하였다. 마이크로 플랫폼은 MEMS 공정으로 제작되었으며, PR(Photo Resist)을 LPR(Liquid Photo Resist)과 DFR(Dry Film Resist)로 각각 2종 씩 선택하여 AAO에 적합한 제품을 선정하였다. 제작된 마이크로 히터는 $1.8mm{\times}1,8mm$로 소형화 하였고, 열손실의 제어를 위해 열확산 방지층을 추가하였다. 구동 온도, 소비전력, 장시간 구동시 안정성의 측정 및 평가는 적외선 열화상 카메라와 kiethly 2420 source meter를 이용하여 측정하였으며, 열확산 방지층의 유 무에 따른 온도 분포 및 소비전력을 비교평가 하였다. 최종적으로는 현재 사용화 되어있는 가스센서들의 소비전력과 비교 평가 하여 논의 하였다.

  • PDF

The Investigation of Combustible Hazard by Measurement of Flash Point and Autoignition Temperature of n-Dodecane (노말도데칸의 인화점과 최소발화온도 측정에 의한 연소위험성 고찰)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.120-125
    • /
    • 2011
  • For the safe handling of n-dodecane, the explosion limits were investigated and the lower flash points and AITs (autoignition temperatures) by ignition delay time were experimented. By using the literatures data, the lower and upper explosion limits of n-dodecanee recommended 0.6 Vol.% and 4.7 Vol.%, respectively. The lower flash points of n-dodecane by using closed-cup tester were experimented $77^{\circ}$ and $80^{\circ}C$. The lower flash points of n-dodecane by using open cup tester were experimented $84^{\circ}C$ and $87^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-dodecane. The experimental AIT of n-dodecane was $222^{\circ}C$.