• Title/Summary/Keyword: 하천변 충적 대수층

Search Result 5, Processing Time 0.026 seconds

Delineation of internal heterogeneities of Geum River point bar deposits in Buyeo area using GPR Data (지하 투과 레이다 조사를 통한 부여 지역 금강변의 충적 대수층 내부 불균질성 파악)

  • Rhee, Chul-Woo;Kim, Hyoung-Soo;Lee, Kyung-Joo
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.337-344
    • /
    • 2002
  • The alluvial deposits along meandering rivers can be used as an artificial aquifer for infiltration of river waters. Internal heterogeneity of the alluvial deposits is a prerequisite information for the development of alluvial groundwater because vortical and lateral movement of alluvial ground water depends on the internal heterogeneity The internal heterogeneity due to variations in channel behavior can be delineated using GPR survey, GPR profiles for the point bar deposits near Buyeo county reveals two different stratigraphic units: the lower inclined heterogeneous strata and the upper horizontally stratified strata. The upper unit is largely indicative of vertical accumulation by overbank floods within a floodplain, whereas the lower one represents typical point bar deposits formed by lateral accretion. The stratigraphic variation in the heterogeneity shows that GPR survey is a useful and necessary investigation method for the development of alluvial ground water.

  • PDF

Evaluation of Stream Depletion from Groundwater Pumping in Deep Aquifer Using An Analytical Model (해석적 모형을 이용한 심부대수층 지하수 양수로 인한 하천수 감소량 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.769-777
    • /
    • 2016
  • The objective of this study was to evaluate the stream depletion from groundwater pumping in deep aquifer using the Ward and Lough's analytical solution (2011) which considers a two-layer leaky aquifer system. The calculated results for each pumping from the 110 wells beside streams showed a wide range of non-dimensional stream depletion, that is the streamflow depletion rate divided by the groundwater pumping rate, from lower than 0.1 to more than 0.9 on average for 5 years depending on the specific properties of well location. From the comparison with Hunt's solution (1999) of a single layer aquifer, the Ward and Lough's solution showed about 50% lower than the Hunt's solution due to the difference of hydraulic properties between the first and second layers as well as the lagged effect of vertical leakance. It was also found that the groundwater pumping has a minor effect on the stream depletion if the stream depletion factor (SDF) of the 1st layer is higher than about 1,000 or the SDF of the 2nd layer is higher than about 100, or the vertical leakance is smaller than $10^{-5}s^{-1}$. Furthermore, in the present study, the variations of the stream depletion were assessed according to the magnitude of unmeasured hydraulic properties such as transmissivity and storage coefficient of the 1st layer, vertical hydraulic conductivity of the 2nd layer, the streambed hydraulic conductance.

Examination for Efficiency of Groundwater Artificial Recharge in Alluvial Aquifer Near Nakdong River of Changweon Area, Korea (창원지역 낙동강 하천수와 주변 충적층을 이용한 지하수 인공함양의 효율성 평가)

  • Moon, Sang-Ho;Ha, Kyoochul;Kim, Yongcheol;Koh, Dong-Chan;Yoon, Heesung
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.611-623
    • /
    • 2014
  • The alluvial aquifer, widely developed near the four major rivers such as Nakdong River, can be used effectively for groundwater artificial recharge and is expected to be the future water resources in Korea. This study is aimed at examining the impact of repeatedly injected river water into the riverside alluvial aquifer on injection rate or efficiency in its system at Changweon area. For this, injection tests were performed two times, first on June 19 and second on September 25 through October 9, 2013, and the mixing ratios of river water to groundwater were used as the tool to compare the efficiency of injection. The mixing ratios were evaluated by using electrical conductivities of injected river water (average $EC=303{\mu}S/cm$) and groundwater ($EC{\fallingdotseq}6,000{\mu}S/cm$) measured at 20 m depth of four observation wells installed 10 m apart from each injection well. The result shows the remarkable differences on two respects. First, in some observation well, detection time for incipient injection effect during $2^{nd}$ injection test was shown to be much slower than that of $1^{st}$ injection test. Second, the hourly increasing rate of mixing ratios in $2^{nd}$ test was revealed to be reduced much more than that of $1^{st}$ test. This means that the efficiency of injection was badly deteriorated by only 1,210 minute injection work. Therefore, injection water needs to be adequately treated beforehand and repeated pumping work and/or resting phase is needed afterwards. To a certain extent, the improvement of water quality in saline aquifer was verified in this system by injection tests.

Effect of Redox Processes and Solubility Equilibria on the Behavior of Dissolved Iron and Manganese in Groundwater from a Riverine Alluvial Aquifer (만경강 하천변 충적 지하수의 용존 Fe와 Mn 거동에 대한 산화-환원 과정과 용해 평형의 효과)

  • Choi, Beom-Kyu;Koh, Dong-Chan;Ha, Kyoo-Chul;Cheon, Su-Hyun
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.29-45
    • /
    • 2007
  • Biogeochemical characteristics involving redox processes in groundwater from a riverine alluvial aquifer was investigated using multi-level monitoring wells (up to 30m in depth). Anaerobic conditions were predominant and high Fe ($14{\sim}37mg/L$) and Mn ($1{\sim}4mg/L$) concentrations were observed at 10 to 20 m in depth. Below 20 m depth, dissolved sulfide was detected. Presumably, these high Fe and Mn concentrations were derived from the reduction of Fe- and Mn-oxides because dissolved oxygen and nitrate were nearly absent and Fe and Mn contents were considerable in the sediments. The depth range of high Mn concentration is wider than that of high Fe concentration. Dissolved organics may be derived from the upper layers. Sulfate reduction is more active than Fe and Mn reduction below 20 m in depth. Disparity of calculated redox potential from the various redox couples indicates that redox states are in disequilibrium condition in groundwater. Carbonate minerals such as siderite and rhodochrosite may control the dissolved concentrations of Fe(II) and Mn(II), and iron sulfide minerals control for Fe(II) where sulfide is detected because these minerals are near saturation from the calculation of solubility equilibria.

A Field Verification Study on the Effect of Filter Layers on Groundwater Level Drop Characteristics, Permeability, Optimum Yield and Well Efficiency in the Unconfined Aquifer Well for Riverbank Filtration Intake (강변여과수 취수를 위한 충적우물에서 필터층이 수위강하특성, 투수성, 적정양수량 및 우물효율에 미치는 영향에 대한 현장실증 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.509-529
    • /
    • 2019
  • This study performs to evaluate the role of filter material at alluvial well for intake of riverbank filtration and the applicability and improvement effect of dual filter well. To achieve this objective, dual filter intake well and single filter intake well were installed with different filter conditions at riverbank free surface aquifer in soil layer then we evaluated filter material condition, permeability, optimum yield and well efficiency according to yield in drawdown test. As a results, we assumed forming dual filter layer minimizes sudden speed changes at boundary between aquifer and filter layer by cushioning of groundwater flow. This suppresses warm current then intake groundwater efficiently, therefore it seems decreasing peripheral groundwater level changes in spite of higher intake water amount than single filter intake well. Furthermore, we confirmed by test, installing dual filter improves permeability, optimum yield and well efficiency. The result will be used by combining with former study to set up standard of design/construction of dual filter intake well at alluvial aquifer layer. Furthermore, we expect this result will be used to prove application effect of dual filter intake well compared to single filter one and radial collector well which are mainly applied on riverbank filtration.