• Title/Summary/Keyword: 하중파형

Search Result 86, Processing Time 0.022 seconds

Evaluation of Bearing Capacity of Waveform Micropile by Numerical Analyses (수치해석을 이용한 파형 마이크로파일의 지지거동 분석)

  • Han, Jin-Tae;Kim, Sung-Ryul;Jang, Young-Eun;Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5906-5914
    • /
    • 2013
  • Recently in Korea, the policy is being proceeded to build a intergenerational housing on artificial ground of railroad site for utilizing rental house. Due to narrow space of rail road site, suitable method have to be developed such as micropiles which is known as a method of a fast construction. However, If micropile is used as foundations for the super structure, construction cost is increases compared with other pile. Consequently, new concept micropile proposed to improve both bearing capacity and cost efficiency of general micropile. New concept micropile consists of waveform cement grout surrounding tread bar that formed by grouting the soil layer with jet grouting method as control the grout pressure and flow. The micropile with waveform is expected to decrease the construction cost by cut down pile length of general micropile. This paper examined the behavior of the new concept micropile with waveform subjected to axial load using two-dimensional axisymmetric numerical analyses method. According to the numerical result, there will cost effectiveness as the pile displacement decreased despite the length of waveform micropile is down about 5% from a general micropile under the same loading condition. Also, the effect of skin friction force which mobilized from the waveform of micropile appeared at relatively soft ground.

Dynamic Analysis of Offshore Structures Considering External Fluid-Structure Interaction (외부유체-구조물의 상호작용을 고려한 해양구조물의 동적해석)

  • Hwang, Chul-Sung;Paik, In-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.271-281
    • /
    • 2005
  • The effects of radiation damping is used to compensate the truncated boundary which is relatively close to the structure-fluid interface in the fluid element surrounding the submerged structures. An efficient ring element is presented to model the shell and fluid element which fully utilizes the characteristics of the axisymmetry. The computational model uses the technique which separate the meridional shape and circumferential wave mode and gets similar result with the exact solution in the eigenvalues and the earthquake analysis. The fluid-structure interaction techniques is developed in the finite element analysis of two dimensional problems using the relations between pressure, nodal unknown acceleration and added mass assuming the fluid to be invicid, incompressible and irrotational. The effectiveness and efficiency of the technique is demonstrated by analyzing the free vibration and seismic analysis using the added mass matrix considering the structural deformation effect.

Evaluation of Minimum Depth Criterion and Reinforcement Effect of the Soil Cover in a Long-span Soil-steel Bridge (장지간 지중강판구조물의 최소토피고 평가 및 토피지반 보강에 대한 수치해석)

  • 이종구;조성민;정현식;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.67-78
    • /
    • 2004
  • Soil-steel bridges are made of flexible corrugated steel plates buried in the well-compacted granular soil. One kind of possible collapses of these structures could be initiated by shear or tension failure in the soil cover subjected to vehicle loads. Current design codes provide the requirements for the minimum depth of the soil cover to avoid problems associated with soil cover failures. However, these requirements were developed for short span (less than 7.7 m) structures which are made of unstiffened plates of standard corrugation (150$\times$50 m). Numerical analyses were carried out to investigate the behavior of long span soil steel bridges according to thickness of the soil cover. The span of structures were up to 20 m and deep corrugated plates (381$\times$140 m) were used. The analysis showed that the minimum cover depth of 1.5 m could be sufficient to prevent the soil cover failure in the structures with a span exceeding 10 m. Additional analyses were performed to verify the reinforcement effect of the concrete relieving slab which can be a special feature to reduce the live-load effects. Analyses revealed that the bending moment of the conduit wall with a relieving slab was less than 20% of that without a relieving slab in a case of shallow soil cover conditions.

A Study on the Damage Assesment of Artificial Brittle Materials subjected to Impact Leading (충격하중을 받은 인공취성재료의 손상평가에 관한 연구)

  • Cho, Sang-Ho;Jo, Seul-Ki;Cheon, Dae-Sung;Synn, Joong-Ho;Yang, Hyung-Sik;Kim, Seung-Kon
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.457-464
    • /
    • 2008
  • Dynamic fracture mechanism of rock is important to improve rapid excavation method and develop precise damage assesment of rock mass in the vicinity of an excavation. In order to investigate dynamic fracture characteristics and dynamic damage mechanism of brittle materials, this study employed pulse shape-controlled Split Hopkinson Pressure Bar (SHPB) system. The P- and S-wave velocities of the tested samples were measured before and after tests to examine damage of the samples. The decay ratios of the Ultrasonic wave velocities increased with impart velocities and the samples which have lower strength showed higher permanent strain significantly.

Wave Deformation and Blocking Performance by a Porous Dual Semi-Cylindrical Structure (투과성 이중 반원통 구조물에 의한 파 차단성능)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.1
    • /
    • pp.10-17
    • /
    • 2010
  • The interaction of oblique incident waves with a porous dual semi-cylindrical structure is investigated under the assumption of linear potential theory. The porous dual semi-cylindrical structure consists of two concentric bottom-mounted cylindrical structures that are porous in front half and transparent in back half. By changing porosity, gap, and wave characteristics(wave frequencies, incidence angle), the wave blocking performance as well as the wave loads and the wave run-up are obtained. As a convenient measure of overall wave blocking performance, the root mean square(R.M.S.) of the wave elevation in a sheltered region is used. It is found that the porous semi-cylindrical structure may significantly reduce the wave response in a sheltered region and the wave forces decrease largely compared to the impermeable structure. The dual structure is more effective in reducing the wave response in a sheltered region than the mono type in the region of high frequencies.

Modal Identification of Structure Using Improved Proper Orthogonal Decomposition Method (개선된 POD기법을 이용한 구조물의 모드식별)

  • Kim, Ho-Geun;Yu, Eun-Jong;Kim, Ji-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.205-208
    • /
    • 2009
  • POD(proper orthogonal decomposition)는 가해지는 하중(입력)의 계측없이 출력(응답)만으로 구조물의 동적특성을 파악할 수 있는 기법이다. 하지만 실제의 경우 측정데이터에 노이즈가 포함되어 있으면 분해가 완전하게 일어나지 않아 동적특성(특히 감쇠비)을 완벽히 파악하기 힘들다. 본 연구에서는 이러한 문제점을 보완하기 위해서 POD기법으로 추출된 각 모드의 자유진동파형에 RD(random decrement)법을 적용하여 노이즈에 의한 영향을 제거하는 방법을 제안하였다. 본 논문에서는 먼저 수치모델을 사용하여 계측노이즈가 있을 경우 제안된 방법을 사용하면 노이즈의 영향을 감소시킬 수 있음을 검증한 후 실험실 규모의 구조물모형에서 얻은 자유진동계측치에 제안된 기법을 적용하여 시스템식별을 수행하여 동특성을 파악하였다.

  • PDF

A Review on Application of Structure Response Spectrum In Blasting Vibration (발파진동의 구조물 응답스펙트럼 응용에 관한 고찰)

  • Lee, Hyo;Kim, Jin-Soo
    • Explosives and Blasting
    • /
    • v.19 no.3
    • /
    • pp.67-74
    • /
    • 2001
  • 발파진동이 건설 환경공해의 한 요인으로서 심각한 사회문제로 대두되자, 이 부분에 대하여 여러 가지 연구활동이 각 관련기관 및 단체에서 이루어져 왔다. 기존의 대부분이 안전 한계치를 제시하는 과정에서 통계처리를 이용한 회귀분석 등이 이용되었으나, 최근에 즈음하여 진동파형 및 주파수 분석 등을 통한 진동 특성을 연구하거나, 발파 진동에 의한 구조물의 응답특성에 관한 연구 등이 병행하여 수행되고 있다. 지진하중에 대한 내진설계 분야에서 구조 동역학적인 개념이 도입 된지 이미 오래지만, 발파공학의 분야에 접목시키기 위한 노력은 최근에 들어와서 보다 활발히 진행되고 있다. 이러한 시도에서 응답스펙트럼은 가장 기초적이며 필수적인 사항 중의 하나라고 생각되며, 본 고찰에서는 이러한 응답스펙트럼의 작성에 대한 기본적인 이해와 몇가지 작성 예를 들어 그 의미를 상기 해보고자 하였다.

  • PDF

Stress Analysis on the Profile of Blast Wall with Finite Element Method (유한요소법을 이용한 방폭벽 프로파일에 대한 응력해석)

  • Kim, Byung-Tak;Koh, Sung-Wi;Kim, Kwang-Heui
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.130-137
    • /
    • 2012
  • Blast walls are integral structures at the typical offshore topside module to provide safety barriers for personnel and critical equipment against any blast loading and hydrocarbon explosions. The blast wall structures are usually configured with stainless steel. It can be referred as the good mechanical properties of the stainless steel against blast load, which features the characteristics of significant energy absorption and ductility. In this study, the proposed designs of corrugated panel are examined in order to determine the best design which satisfies the design criteria. The criteria on maximum deflection and stress are used to decide the best design. The effect of inclined angle of profile on deformation characteristics of blast wall is also performed. The numerical study was performed by using NX Nastran 7.5.

Acoustic Emission from Fatigue Crack Extension in Corroded Aluminum Alloys (부식된 알루미늄 합금의 피로균열진전에서 얻어진 음향방출)

  • Nam Kiwoo;Lee Jonnrark
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • The main objective of this study is to determine if the sources of AE in corroded specimens of aluminum could be identified iron the characteristics of the waveform signals recorded during fatigue loading. Coupons of notched 2024-T3 aluminum with or without corrosion (at the notch) were subjected to fatigue loading and the AE signals were recorded using non-resonant, flat, wide-band transducers. The time history and power spectrum of each individual wave signal recorded during fatigue crack growth were examined and classified according to their special characteristics. Five distinct types of signals were observed regardless of specimen condition. The waveform and power spectra were shown to be dependent on specimen condition. During the initial phase of crack growth, the signals obtained in the as-received specimens are most probably due to transgranular cleavage caused by extrusion and intrusion under fatigue loading. In the corroded specimen the signal are probably generated by intergranular cleavage due to embrittlement of grain boundary neat the pitting tip. The need for additional research to further validate these findings is indicated.

  • PDF

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF