• Title/Summary/Keyword: 하중제어

Search Result 689, Processing Time 0.026 seconds

Literature Review of Model Testing Techniques for Performance Evaluation of Floating Offshore Wind Turbine in Ocean Basin (부유식 해상풍력 시스템 성능평가를 위한 수조모형시험 기법고찰)

  • Yoon-Jin Ha;Hyeonjeong Ahn;Sewan Park;Ji-Yong Park;Dong Woo Jung;Jae-Sang Jung;Young Uk Won;Ikseung Han;Kyong-Hwan Kim;Jonghun Lee
    • Journal of Wind Energy
    • /
    • v.13 no.4
    • /
    • pp.26-41
    • /
    • 2022
  • Three similarities (i.e., geometrical similarity, kinematic similarity and dynamic similarity) between a prototype and model must be satisfied to perform an experiment for a floating offshore wind turbine (FOWT). For dynamic similarity, most of the model tests in ocean engineering basins are performed based on the Froude number, so the scale effect for the wind turbine of an FOWT occurs by different Reynolds numbers between the prototype and model. In this study, various model test techniques for overcoming the scale effect of the wind turbine part of the FOWT are investigated. Firstly, model test techniques using simple approaches are reviewed, and the advantages and disadvantages of the simple approaches are summarized. Secondly, the model test techniques in recent projects that apply improved approaches are introduced including advantages and disadvantages. Finally, new approaches applying digitalization are reviewed, and the characteristics of the new approaches are introduced.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections (콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능)

  • Park, Chang-Hee;Lee, Cheol-Ho;Park, Hong-Gun;Hwang, Hyeon-Jong;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.503-514
    • /
    • 2011
  • In this research, the seismic connection details for two concrete-filled U-shape steel beam-to-H columns were proposed and cyclically tested under a full-scale cruciform configuration. The key connecting components included the U-shape steel section (450 and 550 mm deep for specimens A and B, respectively), a concrete floor slab with a ribbed deck (165 mm deep for both specimens), welded couplers and rebars for negative moment transfer, and shear studs for full composite action and strengthening plates. Considering the unique constructional nature of the proposed connection, the critical limit states, such as the weld fracture, anchorage failure of the welded coupler, local buckling, concrete crushing, and rebar buckling, were carefully addressed in the specimen design. The test results showed that the connection details and design methods proposed in this study can well control the critical limit states mentioned above. Especially, the proposed connection according to the strengthening strategy successfully pushed the plastic hinge to the tip of the strengthened zone, as intended in the design, and was very effective in protecting the more vulnerable beam-to-column welded joint. The maximum story drift capacities of 6.0 and 6.8% radians were achieved in specimens A and B, respectively, thus far exceeding the minimumlimit of 4% radians required of special moment frames. Low-cycle fatigue fracture across the beam bottom flange at a 6% drift level was the final failure mode of specimen A. Specimen B failed through the fracture of the top splice plate of the bolted splice at a very high drift ratio of 8.0% radian.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Development of Rain Shelter for Chinese Cabbage Rainproof Cultivation (배추재배용 비가림하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2014
  • This study was carried out to develop rain shelter which can make an appropriate size and environment for Chinese cabbage rainproof cultivation. Fifty three farms with chinese cabbage rainproof cultivation system have been investigated to set up width and height of rain shelter. Mostly the width of 6m was desired for rain shelter and the height of 1.6m for their eaves, so these values were chosen as the dimensions for rain shelter. After an analysis of their structural safety and installation costs by the specifications of the rafter pipe, Ø$25.4{\times}1.5t$ and 90cm have been set as the size of rafter that such size costs the least. This size is stable with $27m{\cdot}s^{-1}$ of wind velocity and 17cm of snow depth. Therefore it is difficult to apply this dimension to area with higher climate load. In order to sort out such problem, the rain shelter has been designed to avoid damage on frame by opening plastic film to the ridge. Once greenhouse band is loosen by turning the manual switch at the both sides of rain shelter and open button of controller is pushed then switch motor rises up along the guide pipe and plastic film is opened to the ridge. Chinese cabbage can be damaged by insects if rain shelter is opened completely as revealed a field. To prevent this, farmers can install an insect-proof net. Further, the greenhouse can be damaged by typhoon while growing Chinese cabbage therefore the effect of an insect-proof net on structural safety has been analyzed. And then structural safety has been analyzed through using flow-structure interaction method at the wind condition of $40m{\cdot}s^{-1}$. And it assumed that wind applied perpendicular to side of the rain shelter which was covered by insect-proof net. The results indicated that plastic film was directly affected by wind therefore high pressure occurred on the surface. But wind load on insect-proof net was smaller than on plastic film and pressure distribution was also uniform. The results of structural analysis by applying pressure data extracted from flow analysis indicated that the maximum stress occurred at the end of pipe which is the ground part and the value has been 54.6MPa. The allowable stress of pipe in the standard of structural safety must be 215 MPa or more therefore structural safety of this rain shelter is satisfied.

Dynamic Behavior of Reactor Internals under Safe Shutdown Earthquake (안전정기지진하의 원자로내부구조물 거동분석)

  • 김일곤
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 1994
  • The safety related components in the nuclear power plant should be designed to withstand the seismic load. Among these components the integrity of reactor internals under earthquake load is important in stand points of safety and economics, because these are classified to Seismic Class I components. So far the modelling methods of reactor internals have been investigated by many authors. In this paper, the dynamic behaviour of reactor internals of Yong Gwang 1&2 nuclear power plants under SSE(Safe Shutdown Earthquake) load is analyzed by using of the simpled Global Beam Model. For this, as a first step, the characteristic analysis of reactor internal components are performed by using of the finite element code ANSYS. And the Global Beam Model for reactor internals which includes beam elements, nonlinear impact springs which have gaps in upper and lower positions, and hydrodynamical couplings which simulate the fluid-filled cylinders of reactor vessel and core barrel structures is established. And for the exciting external force the response spectrum which is applied to reactor support is converted to the time history input. With this excitation and the model the dynamic behaviour of reactor internals is obtained. As the results, the structural integrity of reactor internal components under seismic excitation is verified and the input for the detailed duel assembly series model could be obtained. And the simplicity and effectiveness of Global Beam Model and the economics of the explicit Runge-Kutta-Gills algorithm in impact problem of high frequency interface components are confirmed.

  • PDF

Evaluation of Seismic Performance of High Strength Reinforced Concrete Exterior Beam-Column Joints Using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 외부 보-기둥 접합부의 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.419-428
    • /
    • 2013
  • In this study, experimental research was carried out to evaluate the constructability and seismic performance of high strength R/C exterior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Five specimens of retrofitted the exterior beam-column joint regions using high ductile fiber-reinforced mortar are constructed and tested for their retrofit performances. Specimens designed by retrofitting the exterior beam-column joint regions (BCJNSP series) of existing reinforced concrete building showed a stable mode of failure and an increased its maximum load-carrying capacity by 1.09~2.03 times in comparison with specimen of BCJNS due to the effect of enhancing dispersion of crack control at the time of initial loading and bridging of fiber from retrofitting new high ductile materials during testing. Specimens of BCJNSP series attained its maximum load carrying capacity by 0.92~0.96 times and increased its energy dissipation capacity by 1.62 times when compared to standard specimen of BCJC with a displacement ductility of 4.

A Study on Improvement of Seismic Performance of High Strength Reinforced Concrete Interior Beam-Column Joints using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능 개선 연구)

  • Ha, Gee-Joo;Hong, Kun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.753-760
    • /
    • 2012
  • In this study, experimental research was carried out to evaluate and improve the constructability and seismic performance of high strength R/C interior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Six specimens of retrofitted the beam-column joint regions using high ductile fiber-reinforced mortar are constructed and tested for their retrofit performances. Specimens designed by retrofitting the interior beam-column joint regions (IJNS series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the enhancement of crack dispersion by fiber bridging from using new high ductile materials for retrofitting. Specimens of IJNS series, designed by the retrofitting of high ductile fiber-reinforced mortar in beam-column joint regions increased its maximum load carrying capacity by 96~102.8% and its energy dissipation capacity by 0.99~1.11 folds when compared to standard specimen of SIJC with a displacement ductility of 5.

Evaluation Method of Self-healing Performance of Cement Composites (시멘트 복합체의 자기치유 성능평가 방법)

  • Lee, Kwang-Myong;Kim, Hyung-Suk;Min, Kyung-Sung;Choi, Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.134-142
    • /
    • 2020
  • In this study, in order to evaluate the self-healing performance of cement composites the self-healing test method and the analysis method were suggested by applying constant water head permeability test, chloride migration test and repeated bending test. The method of making a cracked specimen and controlling crack width are also proposed. Constant head water permeability test can evaluate the healing performance by using the decreasing rate of water flow passing through the crack zone of a specimen. Furthermore, the equivalent crack width can be used to intuitively investigate the healing effect with healing period. The chloride migration test can evaluate the healing rate by the decreasing rate of the diffusion coefficient obtained by ASTM C 1202. Mechanical healing performance can be evaluated using ISR and IDR estimated from load vs. CMOD relationship graph obtained through the repeated bending test. Finally, the applicability of proposed self-healing evaluation methods was examined by testing mortar specimens with or without self-healing agents.

Study on Efficiency of Silicon in PC Dripper of Drip Irrigation (점적관수기의 PC 드립용 실리콘 특성에 관한 연구)

  • Kim, J.H.;Choi, J.M.;Song, N.S.;Kim, D.E.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.56-56
    • /
    • 2017
  • 점적 호스 중 PC 드립은 경질 호스의 내부에 Micro-path가 부착된 유로장치와 압력을 보상하는 연질의 실리콘으로 구성되어 있다. 이때 일정압력에서 적정 길이까지 동시에 내부 압력을 유지하며 균등하게 유출구를 통하여 유량을 공급하는 압력보상 기능이 매우 중요하다. 그러나 이 부분에 대한 기술은 선진국에 비해 아직 부족하여 수입에 의존하는 경향이 매우 높다. 뿐만 아니라 선진국 제품에 비해 유로장치 및 연질 실리콘의 탄성이 균일하지 못해 압력에 따른 유량의 편차가 큰 편이다. 본 연구에서는 우리나라 제품의 PC 드립 압력 균등성 기술을 향상시키기 위해 PC 드립의 핵심기술인 연질 실리콘의 성능에 대한 평가와 유량의 편차를 분석하여 문제점을 통한 개선방안을 제시하고자 하였다. 연질 실리콘의 규격은 $17{\times}8{\times}0.85mm$ (가로${\times}$세로${\times}$두께)로서 Water line의 내부에 결합되어 구성된다. PC 드립용 실리콘은 국내 A사 제품을 중심으로 하여 성능을 측정하였다. 측정을 정밀하게 하기 위해 Microtester를 사용하여 일정하게 하중이 부과되도록 하였다. 연질의 실리콘의 경도는 압력 보상에 중요한 기능을 하고 있으며 또한 PC 드립의 경질 미로와 같이 압력을 제어하는 역할을 하고 있다. 국내 A사의 실리콘 경도는 이상적인 실리콘 경도에 비하면 매우 불균일하였다. 세부적으로는 40 이하의 낮은 경도에서는 비교적 일치하였으나 경도 45 이상에서는 큰 차이를 보여주고 있었다. 국내 A사의 실리콘 경도에 따른 공급유량의 특성에서는 실리콘의 경도가 낮을수록 실리콘은 무르며 탄성이 줄어든다. 반면에 경도가 높을수록 탄성이 커지고 딱딱한 특성을 가진다. 동일한 PC 드립에 실리콘의 경도별 특성은 경도에 따른 유량이 반드시 일정하지 않으며 대체로 경도가 높을수록 동일 압력에 대해 유량이 많아지는 것을 알 수 있었다. 압력의 변화에 대해 유량이 일정하게 유지하는 특성을 가질수록 사용범위가 넓어지고 안정성이 높은 것으로 판단되며 실리콘 경도 35~55 범위에서 1~2bar의 공급압력에서 사용하는 것이 적합할 것으로 보여진다. 경도 45의 실리콘을 사용하여 수입 드립, 국내 A사의 드립 및 수입과 국내 혼용시 압력에 따른 공급유량의 특성을 분석하였다. 최대 유량과 최소 유량에서 발생되는 오차는 수입 실리콘이 비교적 작았으나 3.6 bar 이상에서는 유량이 급격히 떨어지는 양상을 보였다. 국내 A사의 제품은 0.8~2.0 bar 까지 성능이 비슷했으나 0.8 bar 이하에서는 오차가 있었으나 높은 압력에서는 오히려 성능이 우수하였다. 수입 드립과 다소 유사한 성능을 나타낸 것이 A사 드립과 수입 실리콘을 혼용하여 사용한 것은 전체적으로 비슷한 양상을 나타내었다. 따라서 실리콘 경도 오차를 고려하면 압력별 유량의 변화는 실리콘의 경도와 밀접한 관계가 있는 것으로 판단되었다.

  • PDF