• Title/Summary/Keyword: 하중모형

Search Result 887, Processing Time 0.03 seconds

Seismic Performance and Flexural Over-strength of Circular RC Column (원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.49-58
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).

Simplified Nonlinear Static Progressive Collapse Analysis of Steel Moment Frames (철골모멘트골조의 비선형 정적 연쇄붕괴 근사해석)

  • Lee, Cheol Ho;Kim, Seon Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.383-393
    • /
    • 2007
  • A simplified model which incorporates the moment-axial tension interaction of the double-span beams in a column-removed steel frame is presented in this paper. To this end, material and geometric nonlinear parametric finite element analyses were conducted for the double-span beams by changing the beam span to depth ratio and the beam size within some practical ranges. The beam span to depth ratio was shown to be the most influential factor governing the catenary action of the double-span beams. Based on the parametric analysis results, a simplified piece-wise linear model which can reasonably describe the vertical resisting force versus the beam chord rotation relationship was proposed. It was also shown that the proposed method can readily be used for the energy-based progressive collapse analysis of steel moment frames.

Analysis of water level variation effects for the riparian vegetation increase in river channel (하도 내 식생발생에 대한 수위 영향 분석)

  • Kim, Sinae;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.93-93
    • /
    • 2017
  • 2000년대에 들어서면서부터 최근까지 국내 하천의 식생면적이 급격하게 증가되고 있는 추세이다. 댐 등의 하천 횡단구조물로 인한 유황변화에 의해 봄철 발아기 유량 및 수위 저하가 발생하고 이로 인해 식생의 유입된다는 것은 이미 많은 연구에서 증명되고 논의된 바 있다. 그러나 댐과 같은 구조물이 없는 자연하천이나 소하천의 경우에도 식생 유입이 빠르게 진행되고 있는 것은 전국적인 경향이라고 할 수 있다. 우리나라뿐만 아니라 일본의 경우에도 대부분의 하천에서 식생이 유입되고, 제외지 곳곳에서 수림화가 진행되는 현상이 발생하고 있다. 식생의 이입, 번무 등에 대한 원인으로는 홍수량 조절을 위한 댐 운영, 복단면화 및 직강화 등의 하천정비, 골재채취로 인한 인위적 하상변화, 농업용 비료와 같은 영양염류의 유입 등이 주요원인으로 추정되고 있지만 아직까지 정확한 식생 발생 메카니즘에 대한 분석은 이루어지지 않은 상황이다. 일본의 경우 식생의 발생과 진행에 대한 모형을 구축하고 여러 하천에 적용하여 검증하는 연구가 다양하게 진행되고 있지만 지역에 따라 다르게 발생하는 식생의 원인을 단정적으로 결론 내리지는 못하고 있는 실정이다. 본 연구에서는 연도별 강우패턴 변화가 식생발생에 미치는 영향을 분석하였다. 1984년에서 2016년까지 강우패턴을 분석한 결과, 전국적으로 발아기인 3월~9월까지의 강우량이 감소함과 동시에, 기준치 이하의 강수량의 빈도가 점차적으로 증가하고 있는 것으로 나타났다. 이는 하천 내 식생, 특히 버드나무류 교목이 발아하는 봄~초여름에 발생하는 홍수가 감소하였음을 의미하고, 이로인해 하천 내에 초본류, 관목류 뿐만 아니라 교목이 발아 및 활착할 수 있는 가능성이 높아졌음을 의미한다. 또한 식생이 현저하게 증가하고 있는 주요지점의 2007년 이후 하천 단면변화와 시수위를 분석한 결과, 2011년 이후 하도 내 고수부지의 침수시간이 현저하게 감소하였으며, 이는 하천식생의 이입 및 번무에 영향을 줄 뿐만 아니라, 식생활착으로 인한 사주 및 하중도 면적의 증가에도 기여하고 있는 것으로 사료된다.

  • PDF

Structural Performance Analysis of New Type CFTA Girder Bridge (신형식 CFTA 거더 교량의 구조성능평가)

  • Lee, Ji-O;Jeong, Min-Chul;Park, Kyung-Hoon;Kong, Jung-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this research, static load test is performed to verify the arch effect and structural performance of CFTA(Concrete-Filled and Tied steel tubular Arch) girder, and FE(Finite Element) analysis is performed to investigate validity of the test result. CFTA girder is designed to maximize the benefit of each material, such as steel plate, filled concrete and PS tendon. Static load test is performed based on the frame-analysis result of 12m sample miniature model. The result of static load test is that structural performance and safety of CFTA girder are confirmed and there is different deflection mode with other structural form result from arch effect. FE analysis with ABAQUS is also performed to show the validity of the truck collision safety and static load test.

Comparative Experimental Study on Sloshing Impact Loads of LNG Cargoes in Membrane Containment System of 160K LNGC (160K LNGC 멤브레인 화물창에 작용하는 슬로싱 충격 하중에 대한 비교 실험 연구)

  • Kwon, Chang Seop;Lee, Young Jin;Kim, Hyun Joe;Lee, Dong Yeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.2
    • /
    • pp.103-108
    • /
    • 2019
  • A new state-of-the-art sloshing research equipment has developed to perform the model test of LNG tanks for the safer design of LNG cargo containment system in violent sloshing phenomena. This sloshing test system has developed by the Samsung Ship Model Basin (SSMB) and thoroughly verified. The accuracy of the motion of hexapods equipment for the excitation of a model tank has been verified. The maximum displacement in six degrees of freedom, harmonic motions of various frequencies, and irregular motions in wave conditions are measured and compared with input signals. In order to confirm the reliability of the post-processing program for measured impact pressure, the post-processed results were compared with those of the reference institute. A benchmarking sloshing test using 1/50 scale model of 160K LNGC tank was conducted for the verification of the whole testing system. The partial filing levels were considered. As a result of the experiment, it is confirmed that the results are in good agreement with those of the reference institute.

Structural Performance of Beam-to-Column Joint Types in Dapo-style Buildings of the Joseon Dynasty (조선시대 다포계 건축물의 결구형태별 구조성능 평가)

  • Yoon, Jeong-Hoon;Choi, Yun-Chul;Lee, Eun-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.8-14
    • /
    • 2019
  • In Korean traditional wooden architecture, joint performance varies with the material characteristics of timber, the form of joint, the precision of timber-trimming and the like. Case studies prove that the beam-to-column joint type has large influence on the degrees of deformation and spacing. This is not only true of single-story buildings, but also of large-scale multi-story buildings more apparently. Therefore, this study followed the process of examining to joint types, producing their specimens and testing their structural performance. As a consequence of structural test, the dovetail joint specimen showed the best outcomes of the maximum load and rigidity. Synthesizing the structural performances by respective forms of joints, the Doraegeoji dovetail joint specimen showed the higher performance, followed in order by the Doraegeoji mortise joint specimen and the Tongneoko dovetail joint specimen. The structural performance of a building varies with the characteristics by the shouldering forms of penetrating beams and with the joint types within the columns. This should be considered for the new construction or restoration of multi-story buildings, and be continuously researched henceforth.

A Group Pile Effect on Changing Size of Pile Cap in Group Pile under Sand Soil in Earthquake (지진 시 사질토 지반에 근입된 무리말뚝의 말뚝 캡 크기가 무리말뚝 효과에 미치는 영향)

  • Lee, Hyunkun;Ahn, Kwangkuk;Kang, Hongsig
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.10
    • /
    • pp.39-46
    • /
    • 2019
  • The interaction between the ground and structures should be considered for seismic design of group piles supporting the superstructure. The p-y curve has been used widely for the analysis of nonlinear relationship between the ground and structures, and various researches have conducted to apply the dynamic p-y curve for seismic design of group piles. This curve considers the interaction between the ground and structures under the dynamic load such as an earthquake. However the supported effect by the pile cap and the interaction by inertia behavior of superstructures. Therefore, the shaking table test was conducted to verify the effect of the change of the pile cap in group piles supporting superstructures embedded in sandy soil. The test condition is that the arrangement and distance between centers of piles are fixed and the length of the pile cap is changed for various distances between the pile cap side and the pile center. The result shows that the distance between the pile cap side and the pile center have an effect on the dynamic p-y curve and the effect of group piles.

On-line Finite Element Model Updating Using Operational Modal Analysis and Neural Networks (운용중 모드해석 방법과 신경망을 이용한 온라인 유한요소모델 업데이트)

  • Park, Wonsuk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.1
    • /
    • pp.35-42
    • /
    • 2021
  • This paper presents an on-line finite element model updating method for in-service structures using measured data. Conventional updating methods, which are based on numerical optimization, are not efficient for on-line updating because they generally require repeated eigenvalue analyses until convergence criteria are met. The proposed method enables fully automated on-line finite element model updating, almost simultaneously with vibration measurement, without any user intervention or off-line procedures. The automated covariance-driven stochastic subspace identification (Cov-SSI) method is utilized to identify modal frequencies and vectors, and the identified modal data is fed to the neural network of the inverse eigenvalue function to produce the updated finite element model parameters. Numerical examples for a wind excited 20-story building structure shows that the proposed method can update the series of finite element model parameters automatically. It is also shown that sudden changes in the structural parameters can be detected and traced successfully.

Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71% (형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.102-111
    • /
    • 2022
  • The aim of this study is to assess the seismic performance of octagonal hollow cross section reinforced concrete bridge pier, and to investigate the effect of longitudinal reinforcement ratios on the failure behavior. Four octagonal hollow section RC bridge columns of small scale model were tested under a quasi-static cyclically reversed horizontal load with constant axial load. The volumetric ratio of transverse spiral hoop of all specimens was maintained constant(0.206%), the ratios of longitudinal reinforcement were varied(2.36 ~ 4.71%). Failure behavior and seismic performance were investigated. Three specimens with the exception of lap spliced specimen showed flexure-shear failure at final stage. The test results with the exception of lap spliced specimen showed that the displacement ductility factor and accumulated energy dissipation decreased in inverse proportion to the ratio of longitudinal steel.

Development of ETMD(Electromagnetic Tuned Mass Damper) for Smart Control of Structure (구조물 스마트제어를 위한 ETMD(Electromagnetic Tuned Mass Damper)개발)

  • Jeon, Seung-Gon;Heo, Gwang-Hee;Lee, Chin-Ok;Lee, Jae-Hoon;Kim, Dae-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2022
  • The TMD has a simple structure than other vibration control devices and shows excellent control performance for the simple harmonic vibration generated in the structure. However, the vibration control range is narrower than other control devices, making it vulnerable to vibration cycles caused by unexpected external loads. The ETMD developed in this study consisted of Mass with electromagnets. Therefore when supplying a current, the magnetic field is formed to increase the friction force with the friction plate, thereby instantaneously controlling the behavior of the Mass. The experiment was conducted to compare the control performance of the control device by installing the ETMD developed for control performance evaluation in the center of the model simple beam bridge to forced excitation at 3.02 Hz where the maximum bending displacement occurs. As a result of the experiment, ETMD exhibited excellent control performance with a maximum bending displacement attenuation rate of 57.51%.