• Title/Summary/Keyword: 하악소구치

Search Result 239, Processing Time 0.031 seconds

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

A CLINICAL STUDY ON MANDIBULAR MOVEMENT AFTER ORTHOGNATHIC SURGERY (악교정 수술환자의 술전후 하악운동 양상변화에 관한 임상적 연구)

  • Baek, Sang-Heum;Jang, Hyun-Jung;Lee, Sang-Han;Kim, Hyun-Soo;Cha, Doo-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.239-249
    • /
    • 2001
  • The purpose of this study is to evaluate the relationship of the factors which could be influenced by orthognathic surgery especillay SSRO. We measured the amounts of the maximum opening, lateral movements, maximum velocity and pattern of mandibular path during the opening and closing of mandible at the following times ; preoperative, 1 month after operation, 6 months after operation respectively using MKG. And the results were compared according to the categorized subgroups. Following results were obtained : 1. The change of the amounts of mandibular lateral movement and maximum opening velocity were statistically different between male and female (p<0.05), but the others were not. 2. According to the method of operation, there was no difference in the change of the mandibular movements between the group of SSRO and SSRO plus LeFort I osteotomy (p>0.05). 3. According to the amounts of mandibular movement, the recovery of left lateral movement of the group of $6{\sim}10mm$ was better than the other groups (p<0.05). 4. In the frontal pattern of the opening and closing of the mandible, the complex deflected type (F5), simple deflected type (F4), complex deviated type (F3), simple deviated type (F2), straight type (F1) were obtained in order at the time of preoperative, simple deflected type, simple deviated type, complex deviated type, straight type, complex deflected type in order at the time of 1 month after surgery, and the result at the time of 6 months after surgery was the same with that of the time of preoperative. In the sagittal pattern, non-coincident type (S2) was predominant at the time of preoperative, and coincident type (S1) was predominant at the time of 1 month after surgery. After 6 months, the result was also the same with that of the preoperative in sagittal pattern. 5. There was not a statistical difference in the change of the mandibular movement between group of presence of the preoperative TMJ symptoms and non-presence group (p>0.05). 6. There was not a statistical difference in the change of the mandibular movement between repositioning device applied group and non-applied group (p>0.05). 7. Sixty three percents of the patients who had preoperative TMJ symptoms were improved after surgery and preoperative TMJ symptoms were more improved after operation in the repositioning device non-applied group statistically (p<0.05).

  • PDF

Shear bond strength of brackets bonded with different self etching primers (Self etching primer를 사용하여 부착된 교정용 브라켓의 전단결합강도의 비교)

  • Yang, Jin-Young;Kim, Min-Ji;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • The purpose of this study was to evaluate the clinical usefulness of 4 self etching primers by measuring the shear bond strength of orthodontic brackets and examining the failure pattern of bracket-tooth interfaces. Methods: Seventy-five, defect-free, premolars were randomly assigned into five groups: control group (37% phosphoric acid + Transbond XT primer) and self etching primer treated groups (Transbond Plus self etching primer, Unifil bond, Clearfil SE bond, and Adhese). The shear bond strength was measured with a universal testing machine and the amount of residual adhesive remaining on the brackets after debonding was assessed by the adhesive remnant index (ARI). Results: The results showed that the groups conditioned with self etching primer had significantly lower shear bond strength than the control group (p < 0.05), although clinically acceptable. However, there were no significant differences in shear bond strength among the self etching primer groups (p > 0.05). Evaluation of the ARI scores indicated there was less resin remnant on the teeth in the groups conditioned with self etching primers, although not statistically significant. Conclusion: The results of this study suggest that all four of the self etching primers have shown acceptable bond strength for clinical use.

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Clinical evaluation of a new extraction method for intentional replantation (의도적 재식술을 위한 새로운 발치법의 임상 평가)

  • Choi, Yong-Hoon;Bae, Ji-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: Intentional replantation (IR) is a suitable treatment option when nonsurgical retreatment and periradicular surgery are unfeasible. For successful IR, fracture-free safe extraction is crucial step. Recently, a new extraction method of atraumatic safe extraction (ASE) for IR has been introduced. Patients and Methods: Ninety-six patients with the following conditions who underwent IR at the Department of Conservative Dentistry, Seoul National University Bundang Hospital, in 2010 were enrolled in this study: failed nonsurgical retreatment and periradicular surgery not recommended because of anatomical limitations or when rejected by the patient. Preoperative orthodontic extrusive force was applied for 2-3 weeks to increase mobility and periodontal ligament volume. A Physics Forceps was used for extraction and the success rate of ASE was assessed. Results: Ninety-six premolars and molars were treated by IR. The complete success rate (no crown and root fracture) was 93% (n = 89); the limited success rates because of partial root tip fracture and partial osteotomy were 2% (n = 2) and 5% (n = 5), respectively. The clinical and overall success rates of ASE were 95% and 100%, respectively; no failure was observed. Conclusions: ASE can be regarded as a reproducible, predictable method of extraction for IR.

COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS (다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교)

  • Lee, Hyun-A;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.499-506
    • /
    • 2008
  • The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using $PROTAPER^{TM}$ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test wasperformed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05). The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.

THE MORPHOLOGIC CHARACTERISTICS OF CLASS I, NON-EXTRACTION PATIENTS (비발치로 치료된 I 급 부정교합의 형태적 특성)

  • Chang, Young-Il;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.343-351
    • /
    • 1998
  • The purpose of this study was to investigate the pretreatment and posttreatment dentofacial characteristics of non-extraction patients with Class I malocclusion. And to compare this result with matched non-orthodontic normal occlusion and Class I premolar extraction patients. Such comparison might help identify morphologic characteristics of the non-extraction patients. Initial and final cephalometric evaluation were compared in a sample of 22 patients with Class I malocclusions treated in non-extraction manner with edgewise appliance and MEAW The mean age of the total population was 14 years 9 months and the average treatment time was 2 years 8 months. 32 landmarks were located and digitized on each cephalogram. From these landmarks, 24 linear and angular dimension were obtained. Student's t-test were used to compare the pretreatment - posttreatment results, Nonextraction - Normal groups, and nonextraction Extraction groups. Significance was predetermined at $p{\leq}0.05$. The results were as follows. 1. Before treatment, the mean value of the $ODI\;was\;69.9^{\circ},\;APDI\;was\;82.1^{\circ},\;CF\;was\;152^{\circ},\;EI\;was\;152^{\circ}$ in the non-extraction groups. 2. The skeletal pattern of the non-extraction groups were similar with non-orthodontic normal groupsr, but the non-extraction groups had larger interincisal angle. 3. Comparison between groups treated with and without extraction indicated at pretreatment, the extraction groups had more protrusive lips, smaller interincisal angle, and EI. 4. After treatment, there was no significant changes in the skeletal pattern of the non-extraction groups, but uprighting of the maxillary and mandibular first molar and decrease of the interincisal angle were seen.

  • PDF

Effect of Intracanal Medicaments on Push-out Bond Strength of Calcium Silicate-based Materials (근관내 약제가 규산칼슘 기반 재료의 압출 강도에 미치는 영향)

  • Jeong, Hyuntae;Yang, Sunmi;Kim, Seonmi;Choi, Namki;Kim, Jaehwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.455-463
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of the intracanal medicaments on the push-out bond strength of the calcium silicate-based materials. Forty extracted single-root human mandibular premolars were sectioned below cementoenamel junction. Standardized root canal dimension was obtained with a parallel post drill. The specimens were randomly divided into a control group (no medicament), and experimental groups received medicaments with either CH (calcium hydroxide), DAP (double antibiotic paste; a mixture of ciprofloxacin and metronidazole), or TAP (triple antibiotic paste; a mixture of minocycline, ciprofloxacin and metronidazole). Following removal of medicaments with irrigation, roots were cut into sections with 1-mm-thickness. Thereafter, calcium silicate-based materials are applied to the specimens : (i) ProRoot MTA$^{(R)}$ and (ii) Biodentine$^{(R)}$. A push-out bond strength was measured and each specimen was examined to evaluate failure mode. Intracanal medication using CH significantly increased the bond strength to the root dentin. But there are no significant differences on the bond strength of ProRoot MTA$^{(R)}$ or Biodentine$^{(R)}$ among TAP, DAP and control groups. The dislodgement resistance of Biodentine$^{(R)}$ from root dentin was significantly higher than that of ProRoot MTA$^{(R)}$ regardless of the type of intracanal medicaments.

EFFECT OF CURING METHODS OF RESIN CEMENTS ON BOND STRENGTH AND ADHESIVE INTERFACE OF POST (레진시멘트의 중합방법이 포스트의 결합강도와 접착계면에 미치는 영향)

  • Kim, Mun-Hang;Kim, Hae-Jung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.103-112
    • /
    • 2009
  • The purpose of this study was to compare the effect of curing methods of adhesive resins and resin cements in the root canal. Crown portions of 32 single-rooted mandibular premolars were removed. Routine endodontic treatment was done, and 9 mm deep post spaces were prepared within root canals. No.3 FRC Postec posts (Ivoclar-Vivadent AG, Liechtensteih) were cemented in the post spaces by self-(SC) or light-curing (LC) using two dual-cured adhesives (Adper Scotchbond multi-purpose plus and Exite DSC )and resin cements (RelyX ARC and Variolink II). They were assigned to 4 groups (n=8): R-SC, R-LC, V-SC, V-LC group. After stored in distilled water for 24 hours, each root was transversally sectioned with 1.5 mm thick and made three slices. The specimens were subjected to push-out test in a universal testing machine (EZ Test, Shimadzu Co., Japan) with a crosshead speed of 1 mm/min. The data were analyzed with repeated ANOVA and one-way ANOVA. Also the interface of post-resin cement and resin cement-canal wall of each group was observed under FE-SEM. When fiber posts were cemented into the root canal using total-etch adhesives, the bond strength and adaptation between post and root canal dentin was affected by curing method. Self-cure of adhesives and resin cements showed higher bond strength and closer adaptation than light-cure of them.

THE EFFECTS OF DENTIN BONDING AGENT THICKNESS ON STRESS DISTRIBUTION OF COMPOSITE-TOOTH INTERFACE : FINITE ELEMENT METHOD (상아질 접착제의 두께가 치아와 복합레진 경계의 응력발생에 미치는 영향에 관한 유한요소법 연구)

  • Park, Sang-Il;Kim, Ye-Mi;Roh, Byoung-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.442-449
    • /
    • 2009
  • The aim of this study was to examine that thick dentin bonding agent application or low modulus composite restoration could reduce stresses on dentin bonding agent layer. A mandibular first premolar with abfraction lesion was modeled by finite element method. The lesion was restored by different composite resins with variable dentin bonding agent thickness ($50{\mu}m$, $100{\mu}m$, $150{\mu}m$). 170N of occlusal loading was applied buccally or lingually. Von Mises stress on dentin bonding agent layer were measured. When thickness of dentin bonding agent was increased von Mises stresses at dentin bonding agent were decreased in both composites. Lower elastic modulus composite restoration showed decreased von Mises stresses. On root dentin margin more stresses were generated than enamel margin. For occlusal stress relief at dentin boning agent layer to applicate thick dentin bonding agent or to choose low elastic modulus composite is recommended.