• Title/Summary/Keyword: 하수처리장 방류수

Search Result 189, Processing Time 0.03 seconds

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

The Quality Diffusion Study Of Coast in Incheon by Using MIKE 21 (MIKE 21 모형을 이용한 인천연안의 수질 확산 모의에 관한 연구)

  • Choi, Gye-Woon;Lee, Ho-Sun;Lee, Seung-Woo;Kwon, Yong-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.565-570
    • /
    • 2007
  • 최근 들어 인천지역의 개발사업으로 인해 인천연안으로 방류되는 오염물질의 농도가 점점 악화되고 있는 실정이다. 특히, 하수종말처리장 방류수에 의한 인근해안의 영향분석은 중요한 문제 중에 하나라고 할 수 있다. 따라서 본 연구에서는 MIKE21 모형을 이용하여 경기만의 조석전파특성 및 대상지역의 유동상황을 재현하기 위해 하수처리장 증설 지역을 중심으로 경기만 전체를 포함하여 유동해석을 수행하였으며 전체 지역에 대한 유동해석 후 확보한 조석자료를 활용하여 하수처리장 인근지역에 대한 오염물질의 확산 영향에 대해 모의하고 확산방지를 위한 대안을 설정하여 분석을 수행하였다.

  • PDF

Effect of antibiotic resistant factors in effluent of wastewater treatment plant on stream (하수처리장 방류수에 존재하는 항생제 내성인자가 하천에 미치는 영향)

  • Jang, Yejin;Yoo, Yong-Jae;Sul, Woo Jun;Cha, Chang-Jun;Rhee, Ok-Jae;Chae, Jong-Chan
    • Korean Journal of Microbiology
    • /
    • v.53 no.4
    • /
    • pp.316-319
    • /
    • 2017
  • The antibiotic resistant genes (ARG) and mobile genetic elements (MGE) were investigated with the effluent of waste-water treatment plant (WWTP), and river waters of upstream and downstream in order to elucidate the effect of effluent on antibiotic resistance in a natural river. Total numbers of 134~183 of ARG and MGE were detected and the abundance of ARG and MGE was 0.063~0.422 copies per one of 16S rRNA gene in three water samples. Effluent sample contained the highest amount of the total number and abundance of ARG and MGE whereas total viable cells were observed in the lowest amount among the three samples. This indicated that the genes were originated from cells died during the wastewater treatment process. In addition, the co-relationship of abundance between ARG and MGE suggested that acquired resistance was a prevalent mechanism among the antibiotic-resistant bacteria existing in WWTP.

Treatment Efficiency of Existing Forms of Pollutants in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 오염물질의 존재형태별 처리효율)

  • Seo, Dong-Cheol;Lee, Byeong-Ju;Hwang, Seung-Ha;Lee, Hong-Jae;Cho, Ju-Sik;Lee, Sang-Won;Kim, Hong-Chul;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.129-137
    • /
    • 2006
  • A study was conducted to investigate the behavior of pollutant forms at each area in the sewage treatment plant by natural purification method. The sewage treatment plant by natural purification method that consisted of aerobic and anaerobic area was constructed. The efficiency of sewage treatment depending on the operation time, the loading amount of pollutant season variation were investigated. The removal amount of BOD, COD, TOC and SS in the aerobic area was significantly increased as the treatment proceeded. Decreased BOD, COD, TOC, SS, T-N and T-P depending on the loading amount of pollutants in the aerobic and ananerobic area were mostly insoluble BOD (IBOD), insoluble COD (ICOD), soluble TOC (STOC), volatile SS (VSS), dissolved T-N (DTN) and dissolved T-N (DTP) types, respectively. The removal efficiency of BOD, COD, TOC, SS, T-N and T-P in hot season (summer and autumn) were more than that in cold season (spring and winter). The removal efficiencies of BOD, COD, TOC, SS, T-N and T-P of the effluent were about 92, 89, 73, 95, 46 and 84% in all seasons, respectively.

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

The Study to Secure Instream Flow to Improve Natural & Social Environment (자연.사회환경 개선을 위한 하천유지유량 확보방안 연구)

  • Lee, Woo-Suk;Kwon, Moon-Hyuck;Kim, Gee-Hyoung;Na, Sang-Jin;Choi, Hong-Gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.419-423
    • /
    • 2008
  • 하천유량의 직 간접 확보 방안에 대한 설문조사결과 간접 확보방안(18%)보다는 직접 확보방안(82%)을 선호하는 것으로 나타났다. 직접 확보방안에 대한 선호도에 있어서는 (1)하천유수사용허가조정(37%) > (2)기존댐 용수재배분(29%) > (3)신규댐 건설시 확보(16%) > (4)하수처리장 방류수활용(11%) > (5)타수계로부터 도수(7%) 순으로 선호하는 것으로 나타났다. 하천유량의 간접 확보 방안에 대한 선호도는 (1)하천수질 개선(46%) > (2)지하수 관리(24%) > (3)유역 관리(15%) > (4)물절약(10%) > (5)대체수자원(5%)의 순으로 나타났다. 설문조사의 결과를 반영하여 하천유량의 확보는 우선 해당하천의 유역 내에서 우선적으로 확보하도록 하며, 이를 위해 하천 유수사용 재평가에 의한 유수사용허가 조정, 댐 용수 재배분 및 운영율 개선, 신규댐 건설시 하천유지유량 확보, 하수처리장 방류수 활용 방안 등에 대한 검토가 요구된다. 또한 자체 하천 유역에서 확보가 어려운 경우에는 타 하천의 유역에서 인공적으로 도수 하는 방안을 고려하여야 할 것이다. 한편, 장기적으로 수질 개선을 통한 물의 환경기능 제고, 과도한 지하수 개발방지, 산림 및 식생관리, 물절약 및 대체수자원 개발 등을 통해 하천유량을 확보하도록 노력하여야 할 것이다.

  • PDF

Variation of Ecological Flow Applying Physical Habitat in Urban-Stream (도시하천에서 물리서식처를 활용한 생태유량 변화)

  • Im, Dongkyun;Choi, Sung-Uk;Choi, Byungwoong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.104-104
    • /
    • 2015
  • 국내 외에서 생태 수리해석 및 생태 서식 조건을 충족시키기 위한 최적 생태유량 (생태 유지유량) 산정에 대한 연구는 다양하게 진행되어 왔다. 그러나 상대적으로 생태 유지유량을 확보하기 위한 연구는 기존의 방법에서 크게 변화하지 못하고 있는 실정이다. 하천 유지유량을 확보하는 방안은 신규 댐/저수지 개발, 하수처리장 방류수 활용 등과 같은 직접 확보 방안과 댐/저수지 운영 효율 개선, 하천 유수점용허가 관리 등과 같은 간접 확보 방안으로 구분할 수 있다. 그러나 도시 하천에서 유지유량을 확보하기 위해 기존의 방법을 적용하는 것은 현실적으로 한계가 있다. 본 연구는 2차원 물리서식처 모형인 River2D를 이용하여, 물리서식처가 생태유량에 미치는 영향을 분석하였다. 대상구간은 한강의 제1지류인 홍제천으로 선정하였으며, 대상 구간은 하수처리장 방류수를 통해 유지유량이 확보되고 있으며, 추가적인 유지유량을 확보하기 현실적으로 어려운 구간이다. 물리서식처가 생태유량에 미치는 영향을 파악하기 위하여 현재 상태와 추가적인 물리서식처를 고려한 2차원 물리서식처 모의를 진행하였다. 이를 통해 물리서식처를 추가적으로 적용할 경우 현재 상태대비 물리 서식환경이 증가되어 생태유량이 일정부분 확보되는 것으로 나타났다. 본 연구는 도시하천에 물리 서식처를 도입하여 생태 서식공간이 증가함으로써 생태유량을 확보할 수 있는 방안에 대한 방법론을 제시할 수 있을 것으로 기대된다.

  • PDF

Development of a reuse system for agricultural purpose with wastewater in Youljung, Jeju Island (제주 월정 농업용수재이용시스템 개발)

  • Lee, Kwang-Ya;Kim, Hae-Do;Joo, Jin-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.470-470
    • /
    • 2011
  • 환경부 하수재이용사업은 2007년도 하수도법 개정을 통해 공공하수처리시설 처리수의 재이용 의무화를 시작으로 2010년도 "물의 재이용 촉진 및 지원에 관한 법률"의 시행으로 전국적으로 사업이 확대되고 있다. 제주도 월정하수처리장은 2009년도 하수재이용사업지구로 선정이 되어 2010년도부터 농업용목적의 재이용으로 구체적인 설계와 시공이 추진되고 있는 사업지구이다. 제주도에서는 지하수보존을 위해 대체수자원 개발 방안을 시급히 마련중에 있다. 특히, 제주도 농업용수 종합계획수립(제주도, 2004)에는 하수처리수를 농업용수로 이용하기 위한 계획을 수립할 정도로 지하수 사용량을 줄이기 위한 노력을 진행중에 있으며, 그 일환으로 하수재이용사업을 지속적으로 추진하고 있다. 하수처리수의 농업용수 재이용은 사용된 물을 재이용함으로써 물과 에너지를 절약할 수 있고, 유역 또는 해양으로 배출되는 오염원을 억제하는 장점이 있는 반면에 농산물 생육에 직접 영향을 줄뿐만 아니라 주변의 수질 생태 토양 환경 및 영농인의 보건에도 영향을 주기 때문에 장기적인 관찰과 검증작업이 필요하다. 이 에 서울대와 한국농어촌공사는 안전한 농업용수 재이용기술을 개발하기 위해 장기간 현장시험을 통해 재이용 재배기술과 함께 보건환경에 미치는 영향을 검증하였고 그 개발기술을 월정사업지구에 적용하게 되었다. 월정하수처리장이 위치한 제주 동부의 월정지역은 농지면적이 밭(374ha)과 과수(12ha)등 제주도의 전형적인 농촌마을으로 주요 재배작물은 마늘과 당근, 쪽파, 콩 등으로서 농업기반시설의 미비로 영농에 어려움을 호소하고 있으며, 2006년도에 발생한 가뭄으로 그 해 평균 수학량의 30%가 감소된 바 있는 지역이다. 제주도 농업용수 종합계획수립(2004, 제주도)에서는 10년에 한발을 기준 으로 $43,000m^3$/일의 용수가 부족할 것으로 분석하였으며 최근 $35,000m^3$/day 규모의 상수도 확보사업 계획 수립하였으나 여전히 농업용수가 부족하다. 방류수의 수질은 방류수수질기준을 만족하지만 염분함량이 높아 직접 농업용으로 사용하기에는 적당하기 않고, 농업용재이용방류수 수질기준에 맞도록 재이용시스템을 통해 재처리하여 농업용수로 사용해야 한다. 제주도에서는 이미 제주 서부하수처리장 농업용수 재이용사업(이하 판포재이용사업)'이 완료되어 재이용수를 농업용수로 공급하고 있으며 향후 지속적으로 하수재이용사업이 확대될 것으로 판단된다.

  • PDF