• 제목/요약/키워드: 하수처리시스템

검색결과 271건 처리시간 0.032초

하수 2차 처리수 재이용을 위한 저압 및 중압 고도산화시스템의 성능평가 (Assessment of Advanced Oxidation Processes using Low and Medium-Pressure Lamps with H2O2 for Reclamation of Biologically Treated Wastewater Effluents)

  • 안규홍;안석;맹승규;김기팔;홍준석;정민우;권지향
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.542-549
    • /
    • 2003
  • In the present study, the feasibility of $UV/H_2O_2$ systems was investigated using low and medium-pressure lamps on biologically treated wastewater effluents for secondary effluent reclamation. Two types of UV lamps were used as the light sources (a 39-W low-pressure mercury lamp and a 350-W medium-pressure mercury lamp). The results from these UV systems showed that the removal of organic compounds could be achieved in the contact time of longer than 30min (i.e., low UV doses). Efficiencies of color removal and disinfection were far better than those of organic matters measured as TOC, DOC and $TCOD_{cr}$. In the low-pressure lamp UV system, it has been found that DOC and color removals were 60.9 and 86.2% with 50mg/L of $H_2O_2$ and contact times of 30 minute, respectively. Whereas, with the medium-pressure lamp UV system, TOC, DOC and color removal were 27.1, 5.6 and 95% with 14.3mg/L of $H_2O_2$ and 14 minute of contact times, respectively. Both systems could be applied for the reclamation of secondary effluent treated with biological treatment processes.

국내하수에 적합한 BNR 공정 시뮬레이션을 위한 최적 동력학적 계수 산출 (The Analysis of Kinetic Parameters for BNR Process Simulation in Domestic Wastewater)

  • 김대성;박명균;안호철;안원식;이의신
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1385-1390
    • /
    • 2006
  • 외국에서 ASM 모델의 BNR 적용 연구결과를 국내 하수에 적용하기에는 하수농도, 온도, 슬러지농도 등이 국내와는 달라 적용상 무리가 있다. 본 연구에서 BNR 시뮬레이션을 위한 입력 자료로 활용되는 인자들은 IAWPRC task group에서 제안하는 값들을 사용하되 국내 하수성상에서 필요로 하는 인자들은 직접 실험을 통하여 부분적으로 구해냄으로써 모델 시뮬레이션의 신뢰도를 높이고자 하였다. F/M비의 변화량과 1/SRT과의 관계로부터, 종속영양미생물 생산계수 $Y_H$값을 구한결과, 0.40mg VSS/mg COD였다. 이것을 ASM No.2d에 적용하기 위하여 mg cell COD formed/mg COD oxidized 단위로 환산한 결과 0.58을 나타냈다. H 하수처리장의 1차 침전지 하수를 이용하여 호기성상태에서 OUR Test를 통한 미생물에 의한 유기물 섭취시 산소섭취율 변화를 측정하였다. 호기성상태와 무산소상태에서 구한 쉽게 분해되는 용존성유기물(Ss)값을 비교해보면 각각 35.5mg/L와 39.9mg/L로 약간의 차이는 있으나 유사한 값을 보여주고 있다. 시뮬레이션을 위한 동력학적 계수 중 무산소 상태에서 종속영양미생물의 ${\mu}_{max,H}$$3.56d^{-1}$로 나타났고, 호기성상태에서는 구하면 ${\mu}_{max,H}$$4.2d^{-1}$로 산출되었다. 종속영양미생물의 사멸계수 $b_H$를 구하기 위한 실험에서 초기 OUR의 10%이내가 될 때까지 걸린 시간은 7일정도가 걸렸으며, 사멸률 $b_H$$0.043hr^{-1}$로 나타났다. 독립영양미생물의 최대비성장률 ${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하였다.(M1), 무역적자의 폭, 산업의 생산

  • PDF

신경회로망을 이용한 상수처리설비의 약품주입 성능개선에 관한 연구 (A Study on the improvement of Chemicals Dosing Performance using Neural network in a Purification Plant)

  • 류승기;최도혁;홍규장;문학룡;한태환;유정웅
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.104-113
    • /
    • 1998
  • 일반적으로 수처리시설은 상수처리장, 하수처리장 등을 포함하며, 이중에서 상수처리공정은 취수, 응집, 침전, 여파, 살균소독처리 과정으로 구성되어 있다. 그리고, 응집.침선 처리공정은 상수처리시스템에서 가장 핵심부분 으로, 탁도의 처리에 가장 크게 영향을 주게 되며, 이에 따른 응집제의 주입공정을 개선하기 위한 노력이 필요하다. 응집제 주입공정은 응집 반응과정에 관여하는 여러 외부요소들과 탁도와의 관계가 명확히 규정되어 있지 않고, 외부환경조건에 따라 다양하게 변하는 원수로부터 적절한 응집제의 양을 간단하게 결정할 수 없는 상황이다. 따라서, 전반적인 원수처리 공정의 자동화를 위해서는 응집제 주입공정 자동화와 수처과시설의 유지관리기 능을 갖춘 운용지원시스템을 관리자에게 제공하는 것이 요구되었다. 본 논문에서는 수처리시설의 설비유지관리와 응집제 주입공정을 자동화하는 운용지원시스템의 프로토타입올 구현하고자 한다. 응집제 주업공정의 자동화를 위해서 실제 수처리공정에서 1년간 수행된 웅집제 투입양과 원수 의 수질을 결정하는 여러 요소들과의 데이터를 이용하여 신경회로망을 학습시카고, 이를 이용하여 응집제 주업량을 결정하도록 하였다. 이렇게 구축된 웅집제 주입공정 자동화는 운영지원 시스템내 에서 운영되며, 운영지원 시스템은 상수처리설비의 유지분수뜰 위한 설비관리와 상태감시를 하는 환경을 구축하였다.

  • PDF

최적 도시유출시스템의 개발 : I. 도시유출시스템에서의 AHP를 고려한 불명수량 산정에 대한 연구 (Development of Optimal Urban Runoff System : I. Study of Inflow/Infiltration Estimation Considering AHP in Urban Runoff System)

  • 이정호;김중훈;김형수;김응석;조덕준
    • 한국수자원학회논문집
    • /
    • 제37권3호
    • /
    • pp.195-206
    • /
    • 2004
  • 도시유역 하수처리장의 효율을 저감시키는 가장 큰 요인은 하수관내에 발생하는 불명수(Inflow /Infiltration, Ⅰ/Ⅰ)이다. 불명수 저감방안 수립을 위해서는 관로 개개 시설에 대한 조사를 통해 불명수 유입량을 산정해야 한다 그러나, 국내의 경우 재정적, 시간적 한계로 인해 표본조사 결과를 과업대상 전지역에 확대 적용하여 불명수 저감방안을 수 립하고 있다. 이러한 국내의 불명수 산정 방법은 사업대상 전지역의 불명수 총량에 따른 고려만 이루어질 뿐, 관로개개 시설에 대한 불명수 발생량의 고려가 이루어지지 않는 문제점을 나타낸다. 본 연구에서는 도시유역의 유출시스템에서의 불명수량 산정모형을 개발하여 관로 개개 시설에서의 불명수 발생량을 추정하여 불명수 저감방안 수립을 위한 기초자료로 활용하고자 한다. 전체 대상지역에 대한 관측 불명수량은 CCTV 및 육안조사를 통해 조사된 관거별 결함 상태에 따라 관거별로 분배된다. 이때, 결함 항목별 가중치는 AHP(Analytic Hierarchy Process) 기법을 통해 산정 하였으며, 발생 오차를 고려하기 위하여 MCS(Monte Carlo Simulation) 방법을 사용하여 불확실성 분석을 수행하였다.

강우시 하수처리장 일차침전지 월류수 처리를 위한 고효율응집시스템의 적용성 평가 (A Performance Evaluation of the Highly Efficient Coagulation System for the Treatment of Overflows from Primary Clarifier in WWTP)

  • 권은미;오석진;김흥섭;조성주;이승철;하성룡;임채환;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.391-398
    • /
    • 2011
  • This study is to develop highly efficient coagulation system(HECS) that runs treatment with a short retention time to cover the overflow in the rain, which coagulation, mixing and settling are contacted in a single reactor and to estimate the applicability. Setting up 100ton/day-size pilot scale plant, the results of continuous operation in case of runoff, maintaining 20 minute-retention time at optimum chemical injection condition(Alum 100mg/L, Polymer 1.0mg/L) shows the highest removal efficiency(Turbidity 93.1%, TCODcr 80.6%, BOD 81.8%, SS 92.5%, TN 72.3% and T-P 87.3%). It was estimated that the large amount of cost for separate sewage system and the size of area for system instruction can be reduced if the HECS is applied for CSOs treatment because the HECS is so compact and quickly. When we see the results, HECS from this study could be able to treat the pollutant quickly within a short retention time only with coagulant and polymer, which could show high applicability.

우수저류조 용량 결정 방법 (Methodology for determination of rainwater storage capcity)

  • 맹승진;황주하;김다예
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.423-423
    • /
    • 2018
  • 전세계적으로 집중호우, 홍수, 가뭄 등 기상이변이 빈번히 발생하고 있으며, 홍수기와 갈수기가 뚜렷해지고, 이에 따라 수자원 확보에 애로사항이 발생하고 있다. 이를 해결하기 위하여 정부는 "물의 재이용촉진 및 지원에 관한 법률"을 재정하여 효율적인 빗물 관리에 주력을 하고 있으나, 체계적인 빗물관리는 미흡한 실정이다. 즉 수자원을 효율적으로 보관하고 관리할 시스템 구축이 필요하다. 본 연구에서는 재배 작물에 대한 농업용수 확보를 위한 빗물저류조를 시공 및 모니터링을 하기 위하여 먼저 보은군 회인면 오동리의 기상 및 수문특성 조사를 실시하였고, 확률강우량을 산정하기 위해 보은기상관측소의 지속기간별 강우 자료를 수집하여 확률분포를 선정하고 매개변수를 산정하였다. 이에 따른 적합도 검정 결과 최적 확률분포형을 산정하였다. 분석한 결과를 통해 대상지역의 집수되는 면적에 내리는 유출량을 산정하였으며, 집수되는 유형은 지붕으로서 그에 대한 면적은 $120.0m^2$로 측정되었고, 지붕에 대한 유출계수로서 0.9의 값을 적용하였다. 지붕에서 집수되는 유출량의 값을 산정하였으며, 6월의 50년 빈도에서 부족한 9.4톤은 집수된 유출량으로 보충할 수 있는 것으로 판단된다. 따라서 50년 빈도의 10톤을 저류할 빗물은 저류조에서 30%의 여유율을 두어 13톤으로 저류조를 설계하는 것이 적정할 것으로 판단된다. 현재 빗물자원의 대부분은 바다로 유입되어 소모되거나, 하수로 유입되어 불필요한 고도처리공정이 진행되고, 하수처리장 용량에 과부하를 발생시키는 등 막대한 예산이 투입되고 있다. 갈수기시 농가에서 용수를 확보하기 위한 용수 운반장치 등 기반구축과 인력 부족으로 정상적인 용수공급의 어려움을 해결하기 위해서는 빗물자원을 용수로서 효율적으로 활용하기 위한 시스템의 구축이 필요할 것으로 사료된다.

  • PDF

담체가 첨가된 AO$_2$공법을 이용한 수산물 가공폐수의 처리 (Treatment of Seafood Wastewater Using AO$_2$ System with PU-AC Media)

  • 이순;박상원
    • 대한환경공학회지
    • /
    • 제30권6호
    • /
    • pp.666-672
    • /
    • 2008
  • 수산물 가공폐수를 AO$_2$공법에 적용하여 유기물, 질소, 인의 동시제거 가능성을 평가 하였다. 처리도 실험은 도시하수처리장에서 가져온 활성슬러지를 담체에 2주 이상 부착시킨 후 반응조 부피 25%로 충진하여 실험을 행하였다. 유입수 농도는 실험기간 동안 COD : 198 - 1,240 mg/L, TN : 75 - 577.4 mg/L, TP : 2.2 - 53.5 mg/L였다. 운전기간동안 평균 제거효율은 COD : 86.5%(65.7 mg/L), TN : 81.4%(53.1 mg/L), TP : 80.6%(4.07 mg/L)로 나타났다. Anaerobic조와 Aerobic조로 구성된 시스템에 유기물 및 영양염류 부하율이 증가되어도 비교적 안정된 형태의 운전이 가능하였다. 사용된 PU-AC 메디아는 높은 MLSS량을 보유하여 AO$_2$ 시스템 내에서 생물학적 처리율을 높일 수 있었던 것으로 사료된다.

국내 10개 댐저수지 인공습지의 운영현황 및 개선방안 (Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea)

  • 최광순;김세원;김동섭;이요상
    • 한국습지학회지
    • /
    • 제16권3호
    • /
    • pp.431-440
    • /
    • 2014
  • 국내 10개 댐저수지 인공습지를 대상으로 수심분포, 유입량 및 유출량, 물흐름분포, 체류시간, 수처리효율, 종횡비, 개방수역/폐쇄수역 구성비 등 습지의 운영현황 및 구조적 형상에 대한 분석을 통해 인공습지의 수질정화기능을 회복시킬 수 있는 개선대책 및 운영방안을 제시하였다. 조사대상 인공습지의 처리수는 하수처리장 방류수 또는 하천수였으며, 처리수의 수질은 외국의 인공습지에 비해 전반적으로 낮은 것으로 나타났다. 특히 처리수의 BOD는 모든 습지에서 3 mg/L 이하로 매우 낮았는데, 이는 하수처리장의 고도처리 및 평수기 저농도 하천수 취입에 기인된 것으로 판단된다. 수처리효율은 TN이 7.6~67.6%(평균 24.9%), TP가 -4.9~74.5%(평균 23.7%)의 범위로 하수처리장 방류수를 처리수로 하는 인공습지에서 높은 값을 보였다. BOD는 -133.3~41.7% 범위로 습지에 따라 큰 차이를 보였으며, 대부분 습지에서 처리효율이 없거나 낮은 것으로 나타났다. 인공습지의 낮은 처리효율은 습지의 부적합한 종행비, 과도한 개방수역 면적 등의 구조적인 문제와 수위관리 미흡, 초기우수 취입시스템 및 운영관리 미흡, 강우시 모니터링 부재 등의 운영적인 문제에 의한 것으로 나타났다. 그러므로 댐저수지 인공습지가 비점오염 저감시설로서의 역할을 할 수 있기 위해서는 댐저수지 인공습지에 적합한 습지설계 및 운영방안이 필요하다. 또한 습지 운영매뉴얼에 비점오염물질이 유출되는 강우시 모니터링이 반드시 포함되어야 하며, 댐저수지 인공습지의 수처리효율도 강우시 모니터링 자료를 토대로 평가되어야 할 것이다.

수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가 (Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating)

  • 박진호;최현준;이한승;김상열;장현오
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권4호
    • /
    • pp.61-68
    • /
    • 2019
  • 산업화, 도시화로 인해 수자원의 오염이 악화 되면서 기존에 염소를 이용한 정수처리 방법으로는 깨끗한 물을 공급하는데 어려운 실정이다. 이에 오존을 이용한 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 기존의 방수 방식 공법으로 사용되는 에폭시계 방수 방식제 및 스테인리스는 오존의 강력한 산화력으로 인해 열화되어 박리 등 문제 발생하였으며, 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 이에 따라 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속 용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 에 따른 내오존성 평가를 실시하였으며, 실제 하수처리장 환경에서의 전기화학적 안정성능 평가를 실시하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며, 하수처리장 환경에서의 전기화학적 안정성능 평가 결과 용사금속 Ti가 $403.83k{\cdot}{\Omega}{\cdot}cm^2$의 가장 높은 분극저항을 나타남으로써 높은 수준의 내구성을 확보하는 것을 확인할 수 있었다.

뉴로-퍼지 알고리즘을 이용한 슬러지 농도 추정 기법 개발 (Development of Sludge Concentration Estimation Method using Neuro-Fuzzy Algorithm)

  • 장상복;이호현;이대종;권진희;전명근
    • 한국지능시스템학회논문지
    • /
    • 제25권2호
    • /
    • pp.119-125
    • /
    • 2015
  • 정수장, 하수처리장, 폐수처리장의 배출수 처리공정에서 고 농도의 슬러지 선별, 이송 및 약품 투입량 조절을 위한 기준으로 슬러지 농도계가 사용되고 있다. 그러나 슬러지에 함유된 이물질이 혼입될 경우 감쇄량이 증가하거나 초음파가 수신부에 전달되지 않아 실제 농도값 보다 높은 값을 출력하거나 헌팅현상이 발생한다. 또한 단일 센서에 슬러지 포착 또는 고장 등의 문제로 배출수 공정 자동화에 어려움이 많았다. 이러한 문제점을 개선하기 위해 초음파 다중빔 농도계를 개발하여 사용하고 있으나 특정 초음파 빔의 농도 측정값에 오류가 발생할 경우 전체 농도시스템의 성능이 떨어지는 단점이 있다. 따라서 본 논문에서는 초음파 다중빔 농도계 간의 신뢰성을 판단하고, 신뢰성이 높은 다중빔 농도계만을 사용하여 슬러지 농도 예측값의 성능 향상방안을 제시하였다. 예측 알고리즘으로는 뉴로-퍼지모델을 적용하였으며 다양한 실험을 통하여 제안된 방법의 타당성을 검증하였다.