Development of Level of Service by Complaints Characteristics through the Analysis of Complaints Data (민원 자료 분석을 통한 민원 특성별 서비스 관리기준 설정)

  • Park, Mi-Yun;Sho, Byung-Choon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3525-3534
    • /
    • 2015
  • One of the most important requirements in the development of asset management system of wastewater facilities is to determine the level of management of the service related to supply of wastewater. After the sewage facilities were built, many parts of the replacement or repair items will be occurred by the requests of the users on the way of operation and management. To manage the level of those services, where site and which complains is occurred have to be searched, and have to setting the aim of managing the service for objects to improvement. In this study, the complaints related with the sewage of S-area were analyzed, in which is progressed the domestic asset management development for the facilities and pipes related to wastewater. Based on these complaints data, the regional characteristics of S-area by causes and subject of complaints is analysed, and developed more detail management standard than current level. And also service level management strategies of advanced asset management benchmark agency for improving to service level management standard is compared and constructed basement for building the best practice of S area.

An Experimental Study on the Fundamental Properties and Durability of Sewer Type Restorative Mortar Spread with Antibiotics (항균제를 도포한 하수시설용 단면복구 모르타르의 기초물성 및 내구특성에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Kim, Jae-Hwan;Cho, Bong-Suk;Lee, Dong-Heck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 2006
  • Deterioration of sewer concrete is representative that biochemical corrosion according to the $H_2S$ has growth by inhabit sulfur-oxidzing bacteria because of special environment in sewer. But in case of domestic, fundamentally, sulfur-oxidzing bacteria could moderate development of repair material method is need because of corrosion prevent method is inconsideration with carry out to improve project. In this paper, after development of spread type antibiotic with antibio-metal, antibacterial performance about sulfur-oxidzing bacteria of antibiotic and tested to estimate fundamental properties of bonding strength, abrasion contents, contents of water absorption, contents of air permeability, carbonation depth, chloride ion penetration depth and chemical resistance of spread with antibiotic restorative mortar.

Study on a 3D Visualizatiion of Underground Facilities (지하시설물의 3D 시각화에 관한 연구)

  • Kim, Kwang-Ho;Cho, Hong-Beom;Kang, Byung-Jun;Kim, Min-Suck;Kim, In-Hyun
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.06a
    • /
    • pp.232-237
    • /
    • 2008
  • 지하시설물은 상수, 전력, 가스를 공급하고, 하수를 처리하는 동시에 정보통신망을 구축하는 중요한 도시기반시설이기 때문에 지하시설물에 관한 정보가 상당히 중요하게 대두되고 있다. 기존의 도시시설물들은 지상에 설치되어 왔으나 도시의 집중화에 따른 건설안전, 도시 미관, 유지 관리의 용이성을 위하여 시설물을 지하에 매설하는 경향이 높아짐에 따라 이러한 지하시설물의 효과적인 유지관리가 필요하게 되었다. 본 연구에서는 지하시설물 중 상 하수도 정보의 3차원 영상 가시화 기능을 개발하여 도시 지하시설물의 체계적인 관리 기술 및 안전성 확보하고자 하였다. 연구 대상으로 한 3차원 영상 가시화 항목은 현행 도시 관리 체계에서 다루고 있는 지리적 범위내의 지하시설물 중 상 하수도 시설물이다. 도시 지하시설물의 3차원 시각화를 위하여 지하시설물의 항목 별 분류를 수행하였으며 지하시설물의 3차원 시각화 적용 방안에 대한 연구를 수행하였다. 또한 지하시설물 항목별 데이터 관리 방안을 수립하여 3차원 관리 대상 데이터를 제시하였으며 가시화 테스트를 통하여 3차원 영상 가시화 기능을 검증하였다. 본 연구에서 제시한 지하시설물의 3차원 시각화 기능은 도시 지하시설물 관리 기술의 혁신을 선도한 것으로 기대한다.

  • PDF

Feasibility Study on the Treatment of Food Waste Leachate in Municipal Wastewater Treatment Facility - Case of P city - (음폐수 공공하수처리시설 연계처리 타당성 평가 - P시 사례 -)

  • Park, Jong-Hun;Kang, Shin-Young;Kim, Sang-Hyoun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2016
  • P city government considers to treat a part of food waste leachate in a municipal wastewater treatment plant (MWWTP), as the capacity of an existing combined treatment plant for food waste leachate is lower than the generation of food waste leachate in the city. Furthermore, the combined treatment plant also treats landfill leachate and directly discharges the effluent to the sea, which may result in a potential environmental problem. Therefore, this study examined the feasibility of the addition of food waste leachate and the effluent of the combined treatment facility on the MWWTP. Acceptable addition amount of the food waste streams, increased pollution loading on the MWWTP, and the treatment cost were estimated according to four scenarios. All the scenarios estimated that the MWWTP would receive most of the food waste streams according to the manual of the ministry of environment with little increase of pollution loading.

Determination of CSOs Treatment Capacity considering the Pollution Load (오염부하량을 고려한 월류수 처리시설 규모 결정)

  • Kim, Joong Hoon;Yoo, Do Geun;Lee, Eui Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3270-3278
    • /
    • 2014
  • Many researches has been conducted as extreme rainfall in hydrology and extreme rainfall analysis is not proper for determination of CSOs treatment capacity. In this study, runoff is calculated by tranformation from rainfall to runoff according to Interevent Time Definition. The capacity of sewage treatment plant is designed by 3 times of DWF(Dry Weather Flow) and the efficiency of present sewage treatment plant is very low becauseat at present. Also, The sewage treatment plant can not control CSOs. In this research, the pollution load is calculated by EMC(Event Mean Concentration) and pollution concetration of total runoff is a standard deciding suitablility of present sewage treatment plant. Finally, CSOs treatment capacity is determinated considering pollution load.

A Study on the Feasibility of COBie to the Wastewater Treatment Plant (COBie 기반 하수처리시설 유지관리시스템 구축)

  • Choi, Jae-Ho;Um, Dong-Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.273-283
    • /
    • 2014
  • With the introduction of COBie (Construction Operation Building Exchange) in BIM technology enabling an automatic transfer of design and construction information to operation and management (O&M) phase, the BIM centric O&M management system development process has been tested on the subject of architectural types of building. However, for now, there is a need to investigate the technical feasibility of COBie application to civil structures including industrial facilities. This study takes both "O&M Guideline for Public Wastewater Treatment Plant" and a real wastewater treatment plant into account for the purpose, in which the latter is intended to supplement the result of the first. The findings are three-folds: (1) COBie, as an asset modeling, is not sufficient enough to encompass commissioning data, (2) more relevant IFC development and family library build-up useful to modeling wastewater treatment plant is imperative, and (3) well-planned coordination and organization of COBie data-set in line with O&M practice will enhance the feasibility of the COBie in industrial facilities. The result could be used for a basis study for COBie application, particularly in industrial facilities.

A Study on Improving Estimation of Recurrence Rate of Public Water -Jungnangcheon Watershed- (생활용수 회귀수량 산정방법의 개선연구 -중랑천 유역을 대상으로-)

  • Jung, Chung Gil;Ahn, So Ra;Joh, Hyung Kyung;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.509-509
    • /
    • 2015
  • 물 수요관리측면에 대한 정책을 수립하기 위해서는 현재 또는 장래에 대한 용수수급의 정확한 이해를 필요로 한다. 이를 위해서는 용수 수요량 및 공급량뿐만 아니라 여러 산정요소를 필요로 하는데, 그 중 회귀수량은 물이 이용되고 다시 하천으로 회귀되어 이용될 가능성이 있는 수량으로 정의되며, 용수수급 및 용수절약 측면에서 회귀 수량은 중요한 요소라 할 수 있다. 회귀수량 조사는 유역조사 사업 이래, 10년간 생?공용수를 중심으로 미시적, 거시적으로 조사를 시행하였으나, 측정 자료의 신뢰도, 조사방법 및 지점선정 등의 문제로 인하여 조사 성과의 활용성이 매우 낮은 실정이다. 수자원장기종합계획등에서는 수자원관련 계획 수립시 생?공용수의 회귀율을 65 %로 적용하고 있으나, 이는 1970년대 말의 사회적 여건 및 경제적 상황이 반연된 결과로 현재 상황에 적용되기 곤란하다. 따라서, 현재 실정에 맞는 회귀율 산정은 반드시 필요하게 된다. 본 연구에서는 기존 생활용수 회귀수량 산정 연구 한계를 보완하고 유역조사 시행을 위한 개선된 회귀수량을 산정하고자 한다. 본 연구는 서울시 중랑물재생센터 처리구역을 기반으로 중랑천유역을 시험유역으로 선정하였다. 기존 회귀수량 산정방법을 개선하기 위해 시험유역 회귀수량 산정을 위한 가용 자료 분석 및 용수흐름 네트워크 공간분석을 추가로 진행하였다. 가용자료로 시험 유역내 상수공급자료(정수장 공급량, 상수계통도, 유수 및 누수율), 하수처리자료(하수처리구역도, 하수처리계통도, 유입량 및 방류량) 및 기상자료(기상청 지점 및 AWS 강우자료)를 구축하였고 각각의 상수계통도 및 하수처리계통도로부터 용수 흐름 네트워크망을 구축하였다. 상수공급자료로부터 상수계통도 공급지역을 구분하여 월별 유수율에 따른 월별 실 공급량을 산정하였다. 하수처리자료로부터 시험유역에서의 월별하수처리 유입량 및 방류량을 산정하였다. 최종적으로 회귀율(하수처리 방류량/실 공급량)을 산정한 결과 연평균 회귀율은 각각 93.97 %(2011년), 95.02%(2012년)로 과잉 추정 되었으며 7 ~ 9월의 회귀율은 110 ~ 120 %로 유입량을 초과하였다. 이는, 하수처리로 유입되는 유입량의 하수관거는 합류식으로 구축되어 7 ~ 9월에 많은 양의 강우량이 우수관을 통해 하수처리장으로 이송되어 생활용수 이외에 자연적인 공급량으로 인한 것으로 분석되었다. 따라서, 월별 회귀율 산정을 위해서는 불투수층에서의 면적강우량(mm)을 유입량(m3/s)으로 환산된 값을 고려하여 회귀율을 재산정하였다. 그 결과 연평균 회귀율은 각각 78.27 %(2011년), 77.58 %(2012년)로 나타났다.각각의 월별 회귀율도 매우 유사하게 나타났으며 과거 관용적으로 사용된 65 % 회귀율보다 약 12 ~ 13%로 증가하였으며 이는, 하수처리시설 구축 및 처리효율의 증가와 상수처리시설의 관로시설의 개량으로 인한 유수율 및 누수율 감소로 회귀율이 증가한 것으로 판단된다.

  • PDF

A Study on Impact Assessment for Application of Strengthened Compliance Concentration of Effluent Limit from PSTWs in the Jinwee-stream Watershed (유역하수도에서 강화된 방류수 수질 준수농도 적용을 위한 진위천수계 수질영향 평가)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Ki-Hong;Ryu, Jichul;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.397-406
    • /
    • 2015
  • The different compliance concentration of effluent limit is applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof in accordance with the enforced Watershed Sewer System Maintenance Plan in 2013. It is necessary to set the compliance concentration of effluent limit for PSTWs in watershed sewer system, in order to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentration of effluent limit for PSTWs under the plan. The agencies have a plan to apply strengthened effluent BOD concentration limits for PSTWs in I to IV area grade, respectively. Effluent BOD concentration limits will be strengthened from 5~10 mg/L to 3 mg/L in II~III area grade, from 10 mg/L to 5 mg/L in IV area grade. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents assessment methodology which analyze for the compliance concentration of effluent limit to affect water quality of discharge watershed using simulation model for the Jinwee-stream watershed.

The Study on the New Renewal Methods for Rehabilitation of Deteriorated Sewerage by Chemical Attacks (화학침식에 의해 열화된 하수관로 갱생 공법에 관한 연구)

  • Lee, Hee Won
    • The magazine of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.38-52
    • /
    • 2014
  • 도시주민생활에 없어서는 안 될 주요한 사회간접자본시설인 하수도, 하수도처리시설 등의 콘크리트 구조물에 대한 부식열화는 현재 세계 각국에서 급속히 진행되고 있다. 콘크리트 구조물은 반영구적인 것으로 인식하고 있다. 그러나 각종 열화 인자에 의해 구조물의 사용수명은 급속히 단축된다. 하수시설 내에서는 황산이외에도 다양한 염류에 의하여 콘크리트구조물이 부식될 가능성이 있지만 황산에 의한 부식이 가장 대상범위가 넓고 부식속도가 빠르기 때문에 부식현상이 발견되면 급속하고 적절한 대응조치가 필요하다. 열화예측결과 및 구조물의 공용연수를 감안한 신뢰성이 높은 공법의 도입이 필요하며 이러한 조건에 적합한 유기재료와 무기재료의 복합 특성을 발휘하는 갱생공법에 사용되는 주요 소재의 실험적 특성에 관하여 고찰하였다. 그 결과 경질염화비닐(이하 프로파일)은 내외수압 저항성에서 3분간 $1kgf/cm^2$의 압력에도 누수 및 압력의 이동이 없었으며 약품침지에 따른 중량변화량이 $0.2mg/cm^2$이하로 산에 대한 변화량은 거의 없었다. 주입재인 모르타르의 산성에 대한 저항성은 일반 콘크리트에 비해 우수하였으며 기존 모르타르에 비해 비확선성 또한 우수하였다. 장거리압송시험은 200m까지 안정적인 압송이 가능하여 이 기술에 필요한 요구 성능을 확보한 것으로 나타났다.

  • PDF

Numerical Simulation the Effect of Stormwater Treatment on the Water Quality Improvement in a Small Reservoir (초기우수처리에 따른 소규모 저수지 수질개선 효과 수치모의)

  • Ye, Lyeong;Liu, Huan;Lee, Heung-Soo;Kim, Yu-Kyung;Chung, Se-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2064-2068
    • /
    • 2007
  • 합류식 하수도는 오수와 우수를 동시에 배제하는 하수관거 시스템으로 시공이 쉽고 건설비용이 저렴한 반면에 강우시 차집되지 않고 월류되는 유출량으로 인해 수체에 악영향을 초래한다. 관거에서 유출되는 유출수는 강우 초기에 유역에서 집중적으로 유출되는 비점오염원과 하수 및 관거내 오염물질 등을 동반하여 수질 개선을 어렵게 하고 수질 악화를 가중시킨다. 본 연구에서는 기존 유역에 설치된 합류식 하수관거를 분류식으로 개선하고 강우시 초기 세척에 의해 유입하는 비점오염원을 삭감하기 위한 초기우수 처리시설 설치에 따른 M 저수지 수질개선 효과를 수치모델을 사용하여 모의하였다. 저수지의 수질예측은 횡방향 평균 2차원 저수지 수리 및 수질모델인 CE-QUAL-W2를 사용하였다. 저수지 유입량은 군산기상대에서 관측한 일별 강우량 자료를 이용하여 일별 유출량을 산정하였고, 댐 방류량 자료는 M저수지의 2006년 일별 관측수위를 이용하여 유입량과 수위-체적 곡선으로부터 산정하였다. 모델의 보정은 2005년 5월과 8월에 측정한 수질자료를 이용하여 수행하였으며, 저수지의 관측값과 모의결과는 저수지 중앙부 대표지점에서 이루어졌으며, 모델은 관측값을 잘 반영하였다. 모의 결과 M 저수지의 연평균 BOD농도는 합류식(1.25 mg/L)에 비해 분류식 하수 관거(0.91 mg/L)를 도입할 경우 27.2% 개선되었으며, 초기우수 처리시설(0.84 mg/L)을 추가 할 경우 32.8%까지 개선효과가 상승하였다. 기존 합류식 하수관거의 경우 연간 유출부하량은 7,713 kg/yr이었으며, 분류식으로 전환할 경우 2,256 kg/yr, 초기우수처리시설을 추가할 경우 902 kg/yr로 삭감되는 것으로 예측되었다. 분류식하수관거와 초기우수처리를 모두 이행할 경우, BOD와 COD 기준이 호수 수질 기준 II등급 이내로 유지되며, T-P 농도는 0.02mg/L 이하로 유지되어 6월 이후 여름철에 저수지내 조류성장 억제에 효과가 클 것으로 예측되었다. 하수관거 정비사업을 통해 M 저수지는 기존의 농업용 저수지의 목표수질뿐만 아니라, 친수공간으로써 적합한 II등급 수질을 유지할 수 있을 것으로 판단되었다.

  • PDF