• Title/Summary/Keyword: 하수도

Search Result 3,939, Processing Time 0.031 seconds

Selection of Optimum Pebbles Size in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 최적 여재 선정)

  • Seo, Dong-Cheol;Cho, Ju-Sik;Park, Hyun-Geoun;Kim, Hyoung-Kab;Heo, Jong-Soo;Lee, Hong-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.1
    • /
    • pp.26-35
    • /
    • 2003
  • An investigation was carried out to evaluate the effects of pebble size on the small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic plot. pH and EC in both plots varied minimally regardless of pebble size. DO in aerobic plot increased as the pebble size decreased. That in the anaerobic plot was slightly less in comparison with that of the aerobic plot but varied minimally, $2.4{\sim}5.1\;mg/L$ regardless of pebble size. Under all experimental conditions, removals of BOD, COD and turbidity in anaerobic plot were more than 98, 91 and 98, 98% respectively. Removals of T-N and T-P increased as pebble size decreased. Under all experimental conditions, removals of T-N and T-P in anaerobic plot were about $45{\sim}59$ and $480{\sim}96%$, respectively. Judging from the above results, it should be considered that the optimum pebble size and pebble permeability in both plot was $2{\sim}4$ and $0.1{\sim}4\;mm$, respectively.

The Development of a GIS-based Sewer-network Analysis System (GIS를 이용한 하수관망해석시스템 개발)

  • Lee, Jung-Hun;Kim, Kye-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.2 s.12
    • /
    • pp.69-79
    • /
    • 1998
  • It is one of the most crutial thing to secure efficient infrastructure of social infrastructure Including rna drinking water, sewer, gas, and electricity, etc. in modern society. Among them, the sourer system need to be properly maintained so as to sustain water quality over the large watershed thereby to provide reasonable level of living environment A few municipalities and private firms have so in been using sewer management system for assessing existing sewer network and auxiliary facilities. Such existing system can only provide functions to manage the sewer pipe itself and they can not fully estimate the amount of sewage water over the pipe through 4he network analysis due to the deficiency of the system Such a limited sewer network analysis function can only analyze the whole network under the assumption of uniformity. The results from such a process can not be fully implemented in the field. Therefore, this study emphasized the development of a sewer management system which can provide practical values from network analysts considering areal peculiarities using a zoning map utilizing a GIS. The system can support analyzing scenarios due to the changes of sewer amounts from the changes of population densities and rainfall amounts not to mention of calculating sewer amount for individual sewer pipes. furthermore, the system can support the decision making for better designing sewer facilities from the expansion of metropolitan areas and constructing satellite cities. Eventually, it will contribute to enhance the effectiveness of sewer-related works and services for residents as well as supporting a decision making for minor and major trouble-shootings.

  • PDF

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).

Calculation of Rainwater and Groundwater Fraction in Sewerage: A Case Study in Deokjin Park, Jeonju (동위원소를 이용한 하수 내 지하수 및 우수 함량 산출: 전주 덕진공원 유역 사례)

  • Choi, Seung-Hyun;Kim, Kangjoo;Moon, Sang-Ho
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.361-370
    • /
    • 2016
  • It is well known that the inflow of rainwater and the infiltration of groundwater to sewerage (I/I) increase the sewage and burden sewage treatment plants and lower their treatment efficiency. Therefore, it is important to estimate the amount of I/I. In this study, well groundwaters, public water supplies (PWSs), and sewage and rainwater channels were investigated to check whether oxygen and deuterium isotopes could be used as a tool for I/I estimation. This study shows that the isotopic composition of PWS in Jeonju area is very consistent over time and distinctly lighter than the circulating local rainwater (CLR) because it is supplied from Yongdam Dam, which is located about 40 km inland to the east in the mountainous area. Considering the fact that sewage mostly originates from the PWS, we could calculate the amounts of CLR in the sewerage from a monitoring station using unaffected rainwater and tap water as mixing end members. The calculation revealed that the CLR fraction ranged from 50% to 90% depending on observation time. This is well supported by the dilute natures of the sewages at the station. The fraction of PWS in investigated well waters were about 46%, indicating that leaking of PWS is very serious and is an important groundwater source in the study area. Since the infiltration of such groundwater may not alter the isotopic composition of sewage significantly, the actual I/I would be much greater than the calculated ones.

A Study on Impact Assessment for Application of Strengthened Compliance Concentration of Effluent Limit from PSTWs in the Jinwee-stream Watershed (유역하수도에서 강화된 방류수 수질 준수농도 적용을 위한 진위천수계 수질영향 평가)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Ki-Hong;Ryu, Jichul;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.397-406
    • /
    • 2015
  • The different compliance concentration of effluent limit is applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof in accordance with the enforced Watershed Sewer System Maintenance Plan in 2013. It is necessary to set the compliance concentration of effluent limit for PSTWs in watershed sewer system, in order to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentration of effluent limit for PSTWs under the plan. The agencies have a plan to apply strengthened effluent BOD concentration limits for PSTWs in I to IV area grade, respectively. Effluent BOD concentration limits will be strengthened from 5~10 mg/L to 3 mg/L in II~III area grade, from 10 mg/L to 5 mg/L in IV area grade. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents assessment methodology which analyze for the compliance concentration of effluent limit to affect water quality of discharge watershed using simulation model for the Jinwee-stream watershed.

Study on the influence of sewer network simplification on urban inundation modelling results (하수관망의 간소화가 도시침수 모의에 미치는 영향 분석에 관한 연구)

  • Lee, Seung-Soo;Pakdimanivong, Mary;Jung, Kwan-Sue;Kim, Yeonsu
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.347-354
    • /
    • 2018
  • In urban areas, runoff flow is drained through sewer networks as well as surface areas. Therefore, it is very important to consider sewer networks as a component of hydrological drainage processes when conducting urban inundation modelling. However, most researchers who have implemented urban inundation/flood modelling, instinctively simplified the sewer networks without the appropriate criteria. In this research, a 1D-2D fully coupled urban inundation model is applied to estimate the influence of sewer network simplification on urban inundation modelling based on the dendritic network classification. The one-dimensional (1D) sewerage system analysis model, which was introduced by Lee et al. (2017), is used to simulate inlet and overflow phenomena by interacting with surface flow. Two-dimensional (2D) unstructured meshes are also applied to simulate surface flow and are combined with the 1D sewerage analysis model. Sewer network pipes are simplified based on the dendritic network classification method, namely the second and third order, and all cases of pipes are conducted as a control group. Each classified network case, including a control group, is evaluated through their application to the 27 July 2011 extreme rainfall event, which caused severe inundation damages in the Sadang area in Seoul, South Korea. All cases are compared together regarding inundation area, inflow discharge and overflow discharge. Finally, relevant criterion for the simplification method is recommended.

Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants (하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구)

  • Yeo, Wooseok;Kim, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • The standards pertaining to the quality of discharged water in sewage treatment plants are strengthening, and accordingly, facilities in sewage treatment plants are being upgraded. In addition, the discharge water quality of sewage treatment plants must be maintained at a high level, and efficient sewage treatment plant operations have thus emerged as a very important issue. For the efficient operation of sewage treatment plants, this study applied a basic blowing amount calculation method based on sewage facilities to evaluate the required oxygen amount and blowing amount according to inflow water quality by logicizing various influencing factors. As a result of calculating the amount of air blown by applying actual April water quality data from sewage treatment plant A to the blower demand calculation developed through this study, it was found that the average amount of air blown was reduced by about 12%. When the blower demand calculation developed here is applied to an actual sewage treatment plant, the amount of air blown can be controlled based on the inflow water quality. This can facilitate the realization of an autonomous control of sewage treatment plants, in contrast to the existing sewage treatment operation method that relies on operational experience of operator. In addition, it is expected that efficient sewage treatment plants can be operated by reducing blowing amounts and power costs, which will contribute to both energy and carbon savings.

Analyzing Infiltration / Inflow On Seung Gi Basin (승기천 유역에 대한 I/I 분석)

  • Choi Gye Woon;Lee Byung Joo;Chung Yun Jung;Lee Ho Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1323-1327
    • /
    • 2005
  • 도시에서 배출되는 오수나 우수를 모아서 하수처리장 또는 방류수역까지 유하시키는 역할을 하는 관거시설은 하수도 시설의 근간으로서 일반주민의 일상생활과 밀접한 관계가 있기 때문에 시설의 실태를 충분히 파악하여 적절한 유지관리를 시행하지 않으면 안된다. 그러나 지금까지 하수관거에 대한 인식부족으로 인하여 유지관리는 물론 현 실태 또한 제대로 인식 되지 않았다. 따라서 본 연구에서는 인천지역의 승기천 유역을 대상으로 I/I분석 및 예측, 이에 따른 오염 저감 방안을 연구하였다. 본 연구는 승기천 유역 내 주요지점에 대한 관거 I/I 및 하수의 누수량을 조사하기 위하여 고정식 4개 지점(풍림지점, 우성지점, 동막지점, 성주지점)에 대해 하수처리장의 유입수량 및 수질의 영향을 파악하고 해당지역의 관거 문제점을 도출하여 정비방향을 모색하고, 사업시행에 따른 효과분석에 활용하며 성과분석 목표를 수립하기 위한 기초자료를 제공하는데 연구 목적이 있다.

  • PDF

충남 지역 하수 슬러지의 물리$\cdot$화학적 특성에 따른 재활용 방안 연구 - 유기물을 중심으로 -

  • 이기환;이태호;박병빈;최석남
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2000.05a
    • /
    • pp.257-258
    • /
    • 2000
  • 충남 지역에서 발생되는 하수 슬러지를 대상으로 재활용을 위한 물리$\cdot$화학적 특성을 조사하였고, 이를 기초로 유기물 중심의 퇴비화 및 연료화 방안을 검토하였다. 하수 슬러지의 함수율은 약 80 % 정도 되며, 유기물이 고형물의 50 % 정도로 퇴비화를 위해서는 다른 폐기물과의 적절한 혼합이 이루어져야 할 것이며, 부숙기간에 따른 C/N비, 식물 독성 및 중금속의 거동 등과 같은 안정성의 신중한 관리가 절실히 요구된다. 또한, 하수 슬러지에 석유 코우크스를 혼합함으로서 무연탄 수준을 넘는 5,000 kcal/kg 이상의 열량을 확보하여 자체 착화가 가능할 것으로 사료된다. 그리고, 하수 슬러지의 함수율을 낮추기 위한 연구 개발이 시급하게 요구되고 있으며, 건조 공정의 연구개발이 성공적으로 이루어진다면 하수 슬러지의 중량감소에 의한 경제적인 면과 재활용방안의 다각화도 함께 이루어 질 수 있을 것으로 사료된다.

  • PDF

초음파-알칼리 전처리에 의한 도시하수슬러지의 감량화

  • Jeong, Byeong-Gil;Kim, Han-Seok;Kim, Myeong-Suk;Choe, Ho-Eun;Hong, Seung-Mok;Jang, Seong-Ho;Seong, Nak-Chang
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.05a
    • /
    • pp.304-306
    • /
    • 2006
  • 본 연구에서는 하수슬러지의 감량화 방안으로 초음파-알칼리 전처리를 통한 하수슬러지의 가용화 특성과 전처리된 하수슬러지의 비메탄활성도(SMA) 실험을 통한 메탄가스 발생 특성을 살펴본 결과 다음과 같은 결론을 얻을 수 있었다. 하수슬러지의 전처리에서 초음파와 알칼리의 단독 전처리보다는 초음파-알칼리 전처리의 경우, 또한 단일주파수 초음파보다는 이중주파수 초음파의 경우 SCOD 가용화율과 처리시간에 있어 더 효과적임을 알 수 있었다. 알칼리(40meq/L NaOH), 초음파(15, 20, 15+20kHz), 알칼리와 초음파 전처리시(15, 20, 15+20kHz with 40meq/L NaOH)시 반응시간 45분에서 하수슬러지의 세포파괴도가 가장 높게 나타난 것은 알칼리(40meq/L NaOH)와 이중주파수 초음파 15+20kHz 전처리로 조사되었으며, 이때 세포파괴도는 98.7%로 나타났다.

  • PDF