• Title/Summary/Keyword: 하부구조물

Search Result 485, Processing Time 0.026 seconds

A Field-test Study of the Design Standards of Elevated Structures for Rubber-wheeled Light Rail Transit: Braking Force (고무차륜형 경전철 고가구조물 설계기준에 관한 현장 계측 시험 연구(1): 제동하중)

  • Shin, Jeong-Ryol;Lee, An-Ho;Park, Jae-Im;Shin, In-Jo
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.2
    • /
    • pp.133-139
    • /
    • 2014
  • Due to the absence of design guidelines for elevated light-rail structures in Korea, most elevated light-rail structures have been designed and constructed based on the design codes of conventional railway bridges and on the codes recommended by foreign vehicle manufacturers. This is the main reason why most elevated light-rail structures are massive or over-designed or poorly constructed economically. In this paper, the authors carried out field tests to analyze the braking forces caused by braking a train running at speeds of 50km/h, 60km/h, and 70km/h, acting on the elevated structures of rubber-wheeled Light Rail Transit (LRT) trains. The authors also briefly describe the analyzed results of the braking force acting on the substructures of elevated light-rail structures. The test-results presented here in this paper can be referenced when establishing design guidelines or standards for elevated structures of LRT systems.

Efficient Analysis of Building Structures with a Rigid Floor System (주상복합건물의 효율적인 지진해석)

  • 황현식;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 1997
  • Very stiff floor system in a residential-commercial building causes some problems in the numerical analysis procedure due to significant difference in stiffness with adjacent elements. Static analysis of structure with a stiff transfer-floor can be performed approximately in two steps for upper and lower parts for the structure. However, it is impossible to perform dynamic analysis in two steps with separate models. An efficient method for dynamic analysis of a structure with a right floor system is proposd in this study. The matrix condensation technique is employed to reduce the degree of freedom for upper and lower parts of the structure and a beam elements with rigid bodies at both ends are introduce to model the rigid floor system. Efficiency and accuracy of the proposed method are verified through analysis of several example structures.

  • PDF

Influence of Adjacent Structures using Numerical Method during funnel Blasting (터널발파굴착시 수치해석에 의한 구조물의 영향평가)

  • 김학문
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.274-278
    • /
    • 2003
  • The numerical analysis indicated that the vibration response reduced sharply at the three times of tunnel diameter. Visual display of vibration response was possible through 3-D FEM computer program, and displacement of structure, particle velocity were obtained as output. It was found that the vibration velocity was maximum at distance one to two times of tunnel diameter for the given simplified blast loadings. The results of numerical analysis were compared with empirical based predictive equation of blasting. The empirical equation showed a good agreement with 3-D FEM results at a certain range of tunnel depth in this particular type of ground conditions.

  • PDF

Inelastic Nonlinear Analysis of Structures with Under -Tension System (언더텐션 시스템이 적용된 구조물의 비탄성 비선형 거동 해석)

  • Park, Duk-Kun;Lee, Jae-Hong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • This study presents geometric nonlinear and material analysis of under-tension structure using Total Lagrangian and Updated Lagrangian method. In the regard, the under-tension system enables the load of upper part to carry to the end of beam by pre-tensional force in cable. The under-tension system on lower part of the structure is applied in order to reduce the deflection and size of member. This study is performed with conforming of the effect by pretension value in the cable and applying loading. Dead and Live loads are supposed to apply nodal on the top member. The member force and deflection of the structure are with MIDAS and ADINA.

  • PDF

A study on the difference analysis between an ideal and a clinical shape in case of manufacturing a metal-ceramic pontic substructure (금속-도재 가공치 하부구조 제작에서 이상적인 형태와 임상에서 사용되는 형태의 차이 분석)

  • Kim, Wook-Tae;Im, Su-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.8-15
    • /
    • 2016
  • Purpose: The purpose of this research is to determine whether pontic metal substructures, which are currently used in clinical surgeries, are designed appropriately and identify the problems that can occur due to their shape, size, and position. Then it aimed to emphasize the importance of making and designing pontic metal substructures based on basic principles. Materials and Methods: This research measured pontic basal surface (P1) used sample metal substructures in this study, gingiva margin (P2), and the porcelain thickness of maximum infrabulge of labial surface around 1/3 of cervix dentis (P3). One-way ANOVA analysis was carried out to test the differences among groups, Tukey Honestly Significant Difference Test was conducted for statistical analysis among groups. Results: For porcelain thickness and SD value, the P1 part was $1.2-1.8({\pm}0.17)mm$ for experimental group 1, $1.2-1.7({\pm}0.17)mm$ for experimental group 2, and $0.4-2.8({\pm}0.92)mm$ for experimental group 3. Next, the P2 part was $1.4-1.6({\pm}0.07)mm$ for experimental group 1, $1.3-1.8({\pm}0.07)mm$ for experimental group 2, and $0.5-2.7({\pm}0.67)mm$ for experimental group 3. The P3 part was $1.4-1.7({\pm}0.10)mm$ for experimental group 1, $1.5-2({\pm}0.10)mm$ for experimental group 2, and $0.9-3.1mm({\pm}0.90)$ for experimental group 3. There was no significance when One-way ANOVA analysis/Tukey Honestly Significant Difference Test was conducted for statistical analysis among groups (P > 0.05). Conclusion: The suggested metal substructures can be used clinically as they meet the requirements that pontic must have.

어업용 프레임 구조물에 사용되는 평면 그물감의 유수저항

  • 김태호;김재오;정의철;김대안;류청로
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.10a
    • /
    • pp.73-74
    • /
    • 2000
  • 어업용 프레임 구조물 중 부유식의 것은 수면에 떠 있는 프레임과 그 하부에 있는 그물이 조류와 파랑에 의한 저항을 동시에 받고, 낙망 등과 같은 수중 침하식의 것은 그 전체가 조류에 의한 저항을 많이 받기 때문에, 이들 구조물의 안전성은 그들이 받는 저항의 크기에 따라 크게 달라진다. (중략)

  • PDF

Stress Release Zone Around Sub-structure Constructed by Non-open Cut Methods (비개착공법으로 건설된 지하구조물 주변 지반 응력이완영역 규명)

  • Seo, Ho-Sung;Cho, Kook-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.480-488
    • /
    • 2016
  • For the development of areas around railway lines, subsurface construction using the non-open cut method under the railway has recently been increased. However, when a structure under a railway is constructed, the stress release of the ground is not considered an important factor in the design. In this study, laboratory tests were conducted to determine a zone of stress relaxation. Field tests using an inclinometer were performed to measure the horizontal displacement of the ground during non-open cut construction. The stress release zone and the subgrade stiffness were investigated by numerical analysis. The results of the laboratory tests indicated that the failure zone in the ground was similar to a Rankine's active earth pressure zone. The measured data from the inclinometer in the field tests showed that displacements started when a steel pipe was pushed into the ground. The results of numerical analysis show that lateral earth pressure was also close to Rankine's active earth pressure. The roadbed support stiffness of the soil around the structure decreased to 40% of the original value. The ground around the subsurface structure constructed using nonopen cut methods should be reinforced to maintain the running stability of train.

Nonlinear Analysis of Superstructures on Floating Structures (플로팅 구조물의 상부구조에 대한 비선형해석)

  • Song, Hwa-Cheol;Park, Soo-Yong;Jung, Keun-Hoo;Kim, Se-Cheol;Lee, Eun-Suk
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.118-121
    • /
    • 2010
  • 초대형 플로팅 구조물의 상부구조는 육상 구조물과는 달리 파랑하중의 영향을 받기 때문에 하부부체의 변형에 의해서 상부구조물에는 부가 모멘트가 크게 발생한다. 이와 같은 부가모멘트의 저감을 위하여 보-기둥 접합부에 반강접의 도입에 관한 연구와 반강접의 비선형 거동을 고려한 상부구조물의 연구는 초기단계이다. 본 연구에서는 초대형 플로팅 구조물의 상부구조물에 정적하중과 진폭의 크기가 다른 파랑하중이 동시에 작용할 경우 강접 골조와 부분적으로 반강접 접합부가 사용된 상부구조체에 대한 1, 2차 소성해석을 수행하였다. 접합부는 웨브에 더블 앵글을 가진 상하 앵글(TSD)접합을 적용하였으며 상부 구조물에 파랑하중이 작용할 경우 소성거동에 따른 응답특성에 대하여 분석하였다.

  • PDF

The Numerical Analysis for Different Foundations Constructed by Footing and Pile (직접기초와 파일기초로 적용된 이질기초에 대한 수치해석적 평가)

  • Hwang, Eui-Suk;Jang, Kyung-Jun;Thak, Ki-Yoel;Lee, Jong-Sung;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.985-992
    • /
    • 2009
  • 대형 구조물의 기초 시공 시 구조물의 하부지반이 불균질하거나 경사진 지반 또는 일반토사와 암반이 혼재된 지지력이 급격히 변화하는 구간에서 시공되는 경우가 많으며 이와 같은 경우에는 경제적인 최적의 방안으로 직접기초와 말뚝기초를 혼용하여 사용하는 방안이 필요하다. 그러나 일반적으로 기초의 안정성 확보를 위해 보수적으로 말뚝기초를 적용하는 경우가 대부분이며 소규모의 아파트 기초현장에서는 부분적으로 이질기초가 적용되나 이에 대한 보강이나 안정성 검토는 형식적으로 이루어지는 경우가 대부분이다. 본 연구에서는 직접기초와 파일기초가 적용되는 이질기초에 대한 수치해석을 통하여 이질기초 적용 시 기초 및 하부지반에 대한 거동을 평가하여, 이질기초에 대한 적용가능성 여부 및 기초하부에서의 개략적인 거동에 대하여 고찰하고자 한다.

  • PDF

The Response Characteristics of Push-over and Nonlinear Time History Analysis with Variations in the Upper Stories of the Mixed Building Structure (복합구조물의 상부층수 변화에 따른 탄소성 정적 및 동적 응답특성)

  • 강병두;전대한;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.73-83
    • /
    • 2001
  • The mass and stiffness of upper wall-lower frame system(mixed building structures) change sharply at transfer floor due to different structural system in upper and lower part. These mixed building structures generally show the stiffness, weight or geometric vertical irregularities. The purpose of this study is to investigate the response characteristics of these structures by push-over analysis and nonlinear time history analysis. For four types of analysed models, only the variation of upper wall stories was considered. The conclusions of this study are following; (1) In the push-over analysis, yielding hinges in beams and columns of lower frame occurred at the base shear of similar magnitude in all models. But as the number of stories of upper wall increases, yielding hinges at ends of coupling beams were observed in the small magnitude of base shear. (2) In the nonlinear time history analysis, yielding of lower frame occurred at beams with as small ground acceleration as 55gal, and in upper walls yielding was concentrated on coupling beams and shear walls near the transfer floor. (3) As the number of stories of upper walls decreases, the story stiffness of the lower frames decreased relatively and the occurrence of soft stories in the lower frame was observed.

  • PDF