• Title/Summary/Keyword: 필름 센서

Search Result 179, Processing Time 0.03 seconds

Human detecting pyroelectric infrared sensor system using new electrode design (새로운 전극 설계법을 이용한 인체 감지형 초전형 적외선 센서 시스템)

  • 권성열
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.74-78
    • /
    • 2002
  • For human detecting pyroelectric infrared sensor system using more than 2 sensor devices. By new top and bottom electrode design, 1 sensor can sensing human instead of using 2 sensor system. The poled P(VDF/TrFE) film used for sensor pyroelectric materials. The fabricated sensors NEP (noise equivalent power) and specific detectivity D$^*$ of the device were 9.62 $\times$ 10$10^5$ V/W, 3.95 $\times$ 10$10^-175$ W and 5.06 $\times$ 10$10^5$W under emission energy of 13 ${\mu}W/cm^2$ respectively and It's result is almost same result that using more than 2 sensor system for human detecting.

  • PDF

Power Devices for RFID/USN (RFID/USN용 전원소자)

  • Lee, Y.G.;Kim, K.M.;Kim, J.D.
    • Electronics and Telecommunications Trends
    • /
    • v.23 no.6
    • /
    • pp.32-37
    • /
    • 2008
  • 최근 연구가 활성화되고 있는 능동형 전파식별(RFID) 및 유비쿼터스 센서 네트워크(USN) 기술은 그 파급효과가 매우 크고 방대하여 향후 미래 핵심 산업으로 자리잡을 것으로 예상되고 있다. 이러한 RFID 센서 태그 및 USN 센서 노드의 구동을 위해서는 태그나 노드 규격에 적합한 초소형이면서도 경량이고 장수명성을 가지는 전원소자 기술을 확보하는 것이 매우 중요하다. 현재는 이러한 RFID/USN용 센서 태그/노드에 일부 적용되어 그 가능성을 인정받은 전원소자 중 대표적인 것으로 리튬 이차전지와 필름형 일차전지가 있다. 본 고에서는 RFID/USN용 전원소자의 기본 개념 및 규격, 그리고 요구조건 등을 소개하고 국내.외 연구 및 특허 동향과 시장전망 등을 분석하여 향후 기술개발을 위한 참고자료로 삼았으면 한다.

A study on the optimization of the film sensing part for measuring heart rate in wrist (손목에서의 맥박 측정을 위한 필름 센서부 최적화에 관한 연구)

  • Jo, Sung-Hyun;Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.241-244
    • /
    • 2009
  • We studied the optimization method of sensing part for measuring heart rate in wrist. In order to know optimum structure of sensing part, we measured the heart rate signal by changing the shape and size of sensor pad structure and the thickness of silicon. The shapes of structure using in experiment are Empty, Rectangle, Embossing, Length, Width. We were compared the amplitude of output signal about each shape when thickness of silicon pad is increasing from 0 to 7 mm by 1 mm.

  • PDF

Detection the Biomedical Information using the Piezo Film Sensor (Piezo Film Sensor를 이용한 생체 정보 검출)

  • Lee, H.W.;Seo, H.;Jeong, W.G.;Jang, D.B.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 2010
  • For the ubiquitous healthcare environment, real-time measurement of biomedical signals and accuracy of the measured biomedical information are very important. In addition, it is important to develop a healthcare device with low power In this paper, the synchronized pulse in a heartbeat was detected from the radial artery using the piezo film sensor, in order to eliminate inconvenience to wear a pulse detection finger probe. We can get a best output after applying the adaptive noise canceller using two piezo film sensor signals, pulse signal having motion artifacts and motion artifacts reference signal. To detect heartbeat, we use maximum point detection method from pulse removed motion artifacts.

  • PDF

Mechanical Properties of Conductive Polymer as Actuator Materials with Change of Polymerization Condition (합성조건의 변화에 따른 액츄에이터 재료로서의 전도성 고분자의 기계적 특성)

  • Choi, Young;Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.446-451
    • /
    • 1998
  • Recently, conductive polymer is known to be direct-drive active material which can convert electrical energy directly into mechanical energy. In this paper, the polymerized thickness of polypyrrole is measured with change of polymerization conditions and the mechanical bending is analyzed for various polymerized thickness. In order to detect of mechanical bending, bending beam method using the bridge shaped sample is used. Thickness of polypyrrole is proportional to polymerization time in fixed current density. Also it shows a linear relation with the applied current except high current density. Maximum displacement appears at the thickness of $18.35{\mu}m$ which has been polymerized at $5.4{\mu}A/mm^2$ and for 120min and actuated at the frequency of 0.1Hz.

  • PDF

Research on Impact Sensors for Developing the Electronic Body Protector of Taekwondo (태권도 전자호구 개발을 위한 충격감지 센서 연구)

  • Ki, Jae-Sug;Jeong, Dong-Hwa;Lee, Hyun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.648-655
    • /
    • 2019
  • This paper proposes the differential development of a Taekwondo electronic body protector. For this development, the most suitable sensor system was selected after analyzing and testing various sensor methods (magnetic sensors, electric capacity sensors, contact switch sensors, and piezo-film sensors) that could be applied in the electronic body protector, the selected sensors were distributed to the body and feet to make a more precise hit score, unlike the existing system in which all sensors are centralized on the body. Furthermore, it aims to illuminate using a lightweight film-type piezoelectric sensor on the body protector. In the case of an existing electronic body protector, all sensors and network device were concentrated on the body protector, so users need to purchase a set if they want it. On the other hand, the proposed system cloud can be used individually using a smart scoring WEP program. The effects of decreasing weight by up to 20% were compared with those of the existing system. Setting up a test facility is very difficult, so more study will be needed to analyze the effects of a hit.

The study of detector condition proper to the measurement of 6MV small x-rays beam (6MV 소형 x-선 beam 측정에 적합한 검출기의 조건에 관한 연구)

  • Yoo, Myung-Jin;Doh, Shin-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.219-225
    • /
    • 1999
  • The purpose of this study is to measure such parameters as TMR, OAR, TSF for small beams ranging in size from 12.5mm to 40mm by diode, ionization chamber, film, TLD and to determine proper detectors for the measurement of 6MV small x-ray beams. Diode and film show good results within 2% error for the TMR measurement of the beam as small as beam with diameter 12.5mm. Diode and film have excellent spatial resolution in the OAR measurement and the comparison between two detectors shows the error within 3%. But TMR and OAR can not be measured accurately by the ionization chambers. The TSF by diode and TLD records 0.890.96 for the beams with diameter 12.5mm 40mm. The TSF determined by 0.125cc ionization chamber and markus ionization chamber for the larger beams than the beams with diameter 25mm agrees within 2% comparing with that of diode and TLD.

  • PDF

은 도핑 효과를 이용한 그래핀 투명 전도성 필름의 전기적 특성 향상

  • Jeong, Sang-Hui;Lee, Su-Il;Kim, Yu-Seok;Song, U-Seok;Kim, Seong-Hwan;Cha, Myeong-Jun;Park, Sang-Eun;Min, Gyeong-Im;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.566-566
    • /
    • 2012
  • 그래핀(Graphene)은 모든 탄소 동소체의 기본구성 요소로 2 차원 결정구조를 가지며, 양자홀 효과(quantum Hall effect), 뛰어난 열 전도도, 고 탄성, 광학적 투과성 등과 같은 탁월한 물리적 성질을 보이는 물질이다. 이러한 그래핀의 우수한 특성은 전계 효과 트랜지스터(field effect transistor), 화학/바이오 센서, 투명 전극(transparent electrode) 등의 다양한 전자소자를 개발하는 응용 가능하다. 그 중, 그래핀 투명전극의 제조는 가장 응용가능성이 높은 분야이다. 현재 투명전극 물질로는 인듐-주석 산화물(indium tin oxide; ITO)가 널리 이용되고 있으나, 인듐의 고갈로 인한 공급부족 문제 및 고 생산비용, 휘어지지 않는 취성 등의 단점을 지니고 있다. 따라서, 우수한 광학적 투과성과 전기전도성을 지닌 그래핀이 ITO의 대체 물질로서 각광받고 있다.[1-5] 본 연구에서는 그래핀의 투명전도필름의 응용을 위해 면저항을 낮추기 위한 방법으로 화학적 도핑(doping)을 이용하였다. 그래핀은 구리(copper; Cu) 호일을 촉매로 사용하여 열 화학증착법(Thermal Chemical Vapor Deposition)을 이용하여 합성하였다. 합성된 그래핀은 PMMA(Poly(methyl methacrylate)) 전사법을 이용하여 산화실리콘(SiO2) 기판에 전사 후, 염화은(AgCl)과 클로로벤젠(C6H5Cl)으로 만든 콜로이드(colloid) 용액에 디핑(dipping)하여 그래핀에 은 입자를 도핑 하였다. 그 결과, 은 입자 도핑 농도에 따라 면저항이 감소하는 양상을 보였다. 제작된 그래핀 투명전도성 필름의 투과도는 자외선-가시광선-근적외선 분광법(UV-Vis-NIR spectroscopy)를 이용하여 측정하였고, 라만 분광법(Raman spectroscopy)을 통해 그래핀 필름의 질적 우수성과 성장 균일도를 조사하였다.

  • PDF

Characterization of ZnS:(Cu,Al) phosphor using synchrotron radiation (싱크로트론을 이용한 ZnS:(Cu,Al) 형광체의 특성 평가)

  • Jang, Gi-Won;Park, Ji-Koon;Choi, Jang-Yong;Nam, Tae-Woo;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.81-84
    • /
    • 2004
  • 본 논문은 스크린 프린트 방식을 이용하여 두께 $18{\mu}m$의 ZnS:(Cu,Al) 필름을 제조하여 미세구조와 결정성을 분석하고 형광체로써의 특성을 평가하였다. 영상획득에는 포항 가속기 연구소의 싱크로트론을 이용하였으며 CMOS 영상 센서를 사용하여 DR의 간접방식을 구현하였다. 특성 평가를 위해 SEM 측정, 발광 강도 측정을 하였고, 단색광(Beam size $5mm{\times}2mm$)을 사용하여 test phantom 영상과 물고기 영상을 획득하였다. 획득한 영상의 평가를 위해서 test phantom 영상의 MTF 측정을 하였다 제조된 ZnS:(Cu,Al) 필름의 표면은 육방정계 구조를 가졌으며, 5lp/mm는 73.8%, 10lp/mm는 38.9%, 15lp/mm는 15.4%, 20lp/mm는 12.2%의 MTF를 가졌다. 물고기 영상을 통하여 ZnS:(Cu,Al) 필름을 이용한 고해상도 미세구조영상 획득의 가능성을 확인하였다.

  • PDF