• Title/Summary/Keyword: 픽셀화

Search Result 9, Processing Time 0.02 seconds

디지털 홀로그래피를 위한 SLM 기술

  • Kim, Yong-Hae;Hwang, Chi-Seon;Chu, Hye-Yong
    • Information and Communications Magazine
    • /
    • v.31 no.2
    • /
    • pp.21-28
    • /
    • 2014
  • 본고에서 디지털 홀로그래피를 위한 SLM중 대표적인 몇 가지 기술에 대한 동향을 살펴보았다. 먼저 SLM픽셀 피치에 따른 홀로그램 영상의 특성에 대해 논의하고, 픽셀화된 SLM으로써 현재 상용화 되고 있는 DMD SLM 과 LCoS SLM의 특성에 대해 살펴 보았다. 픽셀화 되지 않은 SLM 인 음향 광학 변조기와 OASLM 에 대해서도 살펴 보았다. 양질의 디지털 홀로그래피를 구현하기 위하여 궁극적으로 필요한 픽셀 피치 1 ${\mu}m$ 이하 SLM 의 개발 현황과 복소 변조 SLM 에 대해서도 알아보았다.

Correlation between Building Facade Elements and Defects through "Pixelization Method" (픽셀화기법을 통한 건축물 외벽의 하자와 입면 구성 요소 간의 관계 분석)

  • Kim, Wooram;Jeon, Yongdeok;Shin, Jeongran;Jeong, Kichang;Lee, Jaeseob
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.4
    • /
    • pp.40-48
    • /
    • 2016
  • The construction industry has been made diversified on the design process depending on qualitative growth of customers' demands. But this approach has lead to problems such as falling of building values due to lack of awareness of defects caused by long term utilization. So, the relationship on the characteristics of buildings and defects should be clearly analyzed to prevent falling of building values. This study, therefore, proposed a technique to quantify the relationship between building facade elements and defects. The technique was developed by applying pixel concept to the outside of the buildings. It has a feature to determine the clear relationship by presenting quantitative data that have been recognized qualitatively. The proposed technique is referred to "Pixelization Method". It separates building facade into unit compartment and makes database by assigning a code depending on the characteristics. Through the method, this study is expected to create a foundation for the quantitative analysis of relationship between building facade elements and defects as a basis on active responding to the defects.

A study on the 2D floor plan derivation of the indoor Point Cloud based on pixelation (포인트 클라우드 데이터의 픽셀화 기반 건축물 실내의 2D도면 도출에 관한 연구)

  • Jung, Yong-Il;Oh, Sang-Min;Ryu, Min-Woo;Kang, Nam-Woo;Cho, Hun-hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.105-106
    • /
    • 2020
  • Recently, a method of deriving an efficient 2D floor plan has been attracting attention for remodeling of old buildings with inaccurate 2D floor plans, and thus, studies on reverse engineering of indoor Point Cloud Date(PCD) have been actively conducted. However, in the case of a indoor PCD, due to interference of indoor objects, available equipment is limited to Mobile Laser Scanner(MLS), which causes a efficiency reduction of data processing. Therefore, this study proposes an automatic derivation algorithm for 2D floor plan of indoor PCD based on pixelation. First, the scanned indoor PCD is projected on the XY coordinate plane. Second, a point distribution of each pixel in the projected PCD is derived using a pixelation. Lastly, 2 floor plan derivation based on the algorithm is performed.

  • PDF

Developing Fashion Design Utilizing the Formative Characteristics of Pixelation Image (픽셀화 이미지의 조형 특성을 활용한 패션디자인 개발)

  • Kim, Jinyoung
    • Journal of Fashion Business
    • /
    • v.23 no.4
    • /
    • pp.13-23
    • /
    • 2019
  • This study aims to understand the concept of pixel, the most important factor in constituting a digital image, draw the formative characteristics of pixelation image expressed through non-digital media, and develop fashion design reflecting the characteristics. As a research method, the literature review was conducted in the present study by involving domestic and foreign publications, related academic journals, and theses and dissertations on the pixel and pixelation image based on a qualitative research process. In addition, through an analysis of the cases that borrowed pixelation images in non-digital media like contemporary art and design, etc., an attempt was made to draw the formative characteristics of the pixelation image. Apparently, six fashion design looks are presented in the present study. The formative characteristics of the pixelation image include: first, the repeatability that repeats the minimum unit; second, the incompleteness of the shape appearing through the phenomenon of aliasing due to the characteristics of the pixel; and third, the combination that completes the shape through the combination of individual independent pixels. The results of the expression through reflecting them in fashion design are as follows: first, this study chose one small geometric formative element and presented repeatability by repetitively expressing that element in a textile pattern; second, for incompleteness, this study expressed an incomplete form, handling the edge part of the shape with the method of disentangling the strand; and third, the combination by completing a single look through overlapping of independent textiles and the combination of different independent individuals is expressed.

Study on Increasing the Viewing Angle of the Computer Generated Hologram via Random Pixelated Phase Mask (픽셀화된 랜덤 위상 마스크를 통해 컴퓨터 생성 홀로그램 시야각 확장에 관한 연구)

  • Choi, Woo-Young;Lee, Chang-Joo;Kim, Bum-Su;Oh, Kwan-Jung;Hong, Keehoon;Choo, Hyon-Gon;Park, Jisun;Lee, Seung-Yeol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.311-313
    • /
    • 2020
  • 컴퓨터 생성 홀로그램(CGH)에서 시야각은 매우 중요한 특성이다. 시야각에 따라 홀로그램을 볼 수 있는 영역이 결정되며 시야각을 넘어가게 되면 재구성된 오브젝트가 잘려 보이게 된다. CGH의 최대 시야각은 회절 격자 방정식에 의해 결정이 되며, 해당 수식에 따르면 홀로그램 재생 장치인 공간 광 변조기(SLM)의 픽셀 피치에 반비례한다. SLM의 픽셀 피치를 줄이는 것은 어렵고 비용이 많이 들기 때문에 본 논문에서는 고해상도 랜덤 바이너리 위상 마스크를 SLM에 부착하여 CGH의 시야각을 확장하는 방법을 제안한다. CGH를 계산하는데 자주 사용되는 반복 푸리에 변환 알고리즘(IFTA)에 위상 평균화 단계를 도입하여 SLM과 위상 마스크간의 픽셀 크기 및 개수의 차이를 극복하였다. 또한 스칼라 회절 이론을 바탕으로 한 홀로그램 시뮬레이션에 제안한 방법을 적용 후 가상 눈 모델을 도입하여 두 개의 물체로 이루어진 홀로그램을 재구성하고 여러 각도에서 관찰하여 시야각이 향상되는것을 검증하였다.

  • PDF

Super-Pixel-Based Segmentation and Classification for UAV Image (슈퍼 픽셀기반 무인항공 영상 영역분할 및 분류)

  • Kim, In-Kyu;Hwang, Seung-Jun;Na, Jong-Pil;Park, Seung-Je;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2014
  • Recently UAV(unmanned aerial vehicle) is frequently used not only for military purpose but also for civil purpose. UAV automatically navigates following the coordinates input in advance using GPS information. However it is impossible when GPS cannot be received because of jamming or external interference. In order to solve this problem, we propose a real-time segmentation and classification algorithm for the specific regions from UAV image in this paper. We use the super-pixels algorithm using graph-based image segmentation as a pre-processing stage for the feature extraction. We choose the most ideal model by analyzing various color models and mixture color models. Also, we use support vector machine for classification, which is one of the machine learning algorithms and can use small quantity of training data. 18 color and texture feature vectors are extracted from the UAV image, then 3 classes of regions; river, vinyl house, rice filed are classified in real-time through training and prediction processes.

Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials (방사성 물질 감시를 위한 부호화 구경 감마카메라 개발)

  • Cho, Gye-Seong;Shin, Hyung-Joo;Chi, Yong-Ki;Yoon, Jeong-Hyoun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.257-261
    • /
    • 2004
  • A coded-aperture gamma camera was developed to increase the sensitivity of a pin hole camera made with a pixellated CsI(Tl) scintillator and a position-sensitive photomultiplier tube. The modified round-hole uniformly redundant array of pixel size $13{\times}11$ was chosen as a coded mask considering the detector spatial resolution. The performance of the coded-aperture camera was compared with the pin hole camera using various forms of Tc-99m source to see the improvement of signal-to-noise ratio or the improvement of the sensitivity. The image quality is much improved despite of a slight degradation of the spatial resolution. Though the camera and the test were made for low energy case, but the concept of the coded-aperture gamma camera could be effectively used for the radioactive environmental monitoring and other applications.

Design of the Detector Head for Single Photon Detection in Breast Cancer Diagnosis and Its Performance Evaluation (유방암진단에서의 단일광자검출을 위한 검출기 전단부의 설계와 성능평가)

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.263-270
    • /
    • 2003
  • Monte Carlo simulation has been peformed to induce optimized parameters of the detector head of gamma camera for the diagnosis of breast cancer and to evaluate it under the diagnosis condition of the breast cancer. For the simulation, we used Tungsten collimator, having a lattice structured array with holes of $3mm{\times}3mm$ and septal thickness of 0.25 mm, which are corresponding to the pixellated photosensor. For driving optimum parameters we used Trade-Offs procedure between the geometric efficiency and the spatial resolution, varying the detector head components. In order to pre-evaluate the performance of the optimized detector head, we assumed diagnosis condition that the breast tumor is located in the middle of phantom with various sizes and its location is 25 mm from the collimator surface, considering background count caused by radiation sources from other organs. It was shown that the performance of the optimized detector head can be degraded according to the breast cancer size and the background count under real diagnosis conditions of breast cancer. Therefore, it is concluded that the spatial resolution, which is used as an indicator to distinguish the various sizes of breast cancer and is dependent on the characteristic of the detector head, appears to be meaningless in early diagnosis of the breast cancer.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.