• Title/Summary/Keyword: 피해평가체계

Search Result 302, Processing Time 0.02 seconds

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Estimation of Heading Date using Mean Temperature and the Effect of Sowing Date on the Yield of Sweet Sorghum in Jellabuk Province (평균온도를 이용한 전북지역 단수수의 출수기 추정 및 파종시기별 수량 변화)

  • Choi, Young Min;Choi, Kyu-Hwan;Shin, So-Hee;Han, Hyun-Ah;Heo, Byong Soo;Kwon, Suk-Ju
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.2
    • /
    • pp.127-136
    • /
    • 2019
  • Sweet sorghum (Sorghum bicolor L. Moench), compared to traditional crops, has been evaluated as a useful crop with high adaptability to the environment and various uses, but cultivation has not expanded owing to a lack of related research and information in Korea. This study was conducted to estimate heading date in 'Chorong' sweet sorghum based on climate data of the last 30 years (1989 - 2018) from six regions (Jeonju, Buan, Jeongup, Imsil, Namwon, and Jangsu) in Jellabuk Province. In addition, we compared the growth and quality factors by sowing date (April 10, April 25, May 10, May 25, June 10, June 25, and July 10) in 2018. Days from sowing to heading (DSH) increased to 107, 96, 83, 70, 59, 64, and 65 days in order of the sowing dates, respectively, and the average was 77.7 days. The effective accumulated temperature for heading date was $1,120.3^{\circ}C$. The mean annual temperature was the highest in Jeonju, followed in descending order by Jeongup, Buan, Namwon, Imsil, and Jangsu. The DSH based on effective accumulated temperature gradually decreased in all sowing date treatments in the six regions during the last 30 years. DSH of the six regions showed a negative relationship with mean temperature (sowing date to heading date) and predicted DSH ($R^2=0.9987**$) calculated by mean temperature was explained with a probability of 89% of observed DSH in 2017 and 2018. At harvest, fresh stem weight and soluble solids content were higher in the April and July sowings, but sugar content was higher in the May 10 ($3.4Mg{\cdot}ha^{-1}$) and May 25 ($3.1Mg{\cdot}ha^{-1}$) sowings. Overall, the April and July sowings were of low quality and yield, and there is a risk of frost damage; thus, we found May sowings to be the most effective. Additionally, sowing dates must be considered in terms of proper harvest stage, harvesting target (juice or grain), cultivation altitude, and microclimate.