• Title/Summary/Keyword: 피토관

Search Result 35, Processing Time 0.023 seconds

Analysis and Performance Test for the Fan of a Wide Area Sprayer of Livestock Farm (축산 농가용 광역방제기 팬의 성능실험 및 분석)

  • Hong, J.T.;Min, B.R.;Kim, D.W.;Seo, K.W.;Kim, W.;Lee, S.K.;Kim, S.Y.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.105-112
    • /
    • 2007
  • This research was carried out to test and analyse the capability of a fan for development of a sprayer in actual livestock farm. A fan was designed and made to be able to spray agricultural chemicals within 140mm in a maximum scattering range and 100m in an effective scattering range. Accordingly, its' flow rate was $3,600\;m^3/min$, and static pressure was 100 mmAq for a wide area sprayer to be sprayed widely and far. Fan performance, which was given $600\;m^3/min$ flow rate and 500 mmAq total pressure, was tested fur basic experiment. As the result, the axial power showed minimum error, which be designed to keep the fan performance. And power efficiency was the maximum. Sound level was 92.1dB that wasn't enough to environmental standard. If we take the sealed place into consideration, sound level is suitable for environmental standard.

  • PDF

Fully Developed Turbulent Flow in Roughened Concentric Annuli : Experiment and Analysis (거친환형관내의 완전히 발달된 난류유동 : 실험과 해석)

  • Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.4 no.2
    • /
    • pp.17-24
    • /
    • 2000
  • 직경비가 0.26, 0.39, 그리고 0.56인 경우 거칠기를 내벽면에, 외벽면에, 그리고 양벽면에 각각 설치한 동심환형관에서 완전히 발달된 난류유동에 대한 거칠기 효과를 실험과 이론으로 해석하였다. 그리고 거칠기 효과를 정량적으로 파악하기 위해 양벽면 모두 매끈한 환형관의 경우도 포함하였다. 실험에서 마찰계수를 구하는데 필요한 속도분포와 전단응력들은 피토튜브와 X-형 열선풍속계를 사용하였다. 이론 해석은 수정대수 난류모델을 사용하였고 그 결과를 이론값과 비교하여 아래의 결론을 얻었다. 1) 무디다이어그램 (Moody diagram)은 거칠기가 설치된 이중관에는 적용할 수 없음을 보였다. 2) 경우(c) 와 (d)에서는 반경비가 클수록 반드시 마찰계수가 증가하지 않았다. 3) 4개의 경우중 거칠기로 인해 마찰계수가 증가하는 크기의 순서는 경우(d)가 가장 컸고 경우(a)가 가장 작았다.

  • PDF

Effect of Roughness Position on the Characteristics of Turbulence in Concentric Annuli (동심환형관에서 난류특성에 미치는 조도위치의 효과)

  • Ahn, S.W.;Lee, W.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.61-69
    • /
    • 1997
  • 본 연구는 동심환형관에서 거칠기가 없이 매끈한 경우, 내측벽에 만, 외측벽에 만, 그리고 양측 모두에 거칠기가 있는 4경우에 대해 직경비가 0.26, 0.39, 그리고 0.56일 때 벽면에 설치된 거칠기 위치들이 난류유동장에 미치는 효과를 실험적으로 조사하고자 한다. 최대속도와 전단응력이 0인 지점들, 시간평균속도의 구배들, 그리고 와확산계수들을 X형 열선풍속계와 이중 피토튜브를 사용하여 측정하였다. 본 연구를 통하여 동심환형관에 설치된 거칠기들이 난류유동에 미치는 효과에 대한 정량적자료를 제시할 수 있었다.

  • PDF

Experimental Approach for Estimation of Hydrodynamic Force Acting on a Submerged Streamlined Body Translating in a One-end-opened Cylindrical Tube (수중운동체의 실린더 관 내부 이동시 작용력 예측에 대한 실험적 접근)

  • Yeo, Dong-Jin;Kim, Yeon-Gyu;Kim, Dong-Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.203-211
    • /
    • 2012
  • The main object of this experiment is to estimate the hydrodynamic forces acting on a submerged streamlined body placed in a one-end-opened cylindrical tube moving with certain translational velocity. The best experimental design for this object is mimicking real situation, however sizes of model body and cylinder tube are just the same as those of real, for avoiding scale effects, mimicking real situation is not realizable. Hence, in this experiment, target body and cylindrical tube were designed to be towed with varying body position relative to cylindrical tube. For measuring hydrodynamic forces and flow velocity in the cylindrical tube, six one-component load cells and several one-hole Pitot tubes were used. Several conditions were checked with various end-plates those had different opening areas. Experiment results show that forces and flow velocity had different tendency with those expected, and the presence of a end-plate slows down the flow velocity in the cylindrical tube and affects pressure field in the tube to push the model submerged body forward of the tube. This tendency grows with decreasing opened area.

Study on the Aerodynamic Characteristics of Hanyang Low Speed Wind Tunnel (한양대학교 중형 아음속 풍동의 공력특성에 관한 연구)

  • Go, Gwang Cheol;Jeong, Hyeon Seong;Kim, Dong Hwa;Jo, Jin Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.92-98
    • /
    • 2003
  • The optimum design of Hanyang low speed wind tunnel has been performed to augment flow uniformity and to reduce turbulence intensity of wind tunnel test section have to be known for reliability of wind tunnel test. The non-uniformity and turbulence intensity of Hanyang low speed wind tunnel were measured with Pilot tube and X-type hot-wire probe at various wind speeds. As the results, the non-uniformity decreases as the wind speed increases. The non-uniformity is relatively high in the proximity of the diffuser. The turbulence intensity is a little higher than design requirement in the middle of the test section.

Experimental Study on the Performance of a Forward-Curved Centrifugal Fan for an Automotive Air-Conditioner (자동차 에어컨용 전곡형 원심 송풍기의 공력성능 분석)

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.122-128
    • /
    • 2000
  • Aerodynamic optimization of an automotive air-conditioning blower is a hard task because of the highly complex flow phenomena related to three-dimensional flow separations and the unsteady nature caused by the interaction between primary and secondary air flows throughout the fan. In this paper, an aerodynamic study on a forward-curved centrifugal fan has been carried out Firstly we obtained the fan performance curves versus flow rates showing its unstable nature in the surging operation range. Secondly aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage using a 5-hole pilot probe, at different operating conditions. Surface flow pattern near the cut-off area exhibits similar flow behavior above the best efficiency operating point, although the pressure level increases substantially with the Increase of flow rate. Vorticity in the casing passage flow occurs in all (low rates, downstream from the r-Z plane $\theta$=120 deg., where the position of its core changes with the circumferential location. Although complex, the general flow behavior were common, giving insight in its main aerodynamic features.

  • PDF

A Study on Flow Velocity Distribution at Inlet and Exit of Diesel Particulate Filter with L-Shape Inlet Connector Using Automatic Measurement (측정자동화에 의한 입구연결부 형상이 L-형인 디젤매연필터 입.출구에서의 유속 분포에 관한 연구)

  • Lee, Choong-Hoon;Bae, Sang-Hong;Choi, Ung;Lee, Su-Ryong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.4
    • /
    • pp.93-100
    • /
    • 2007
  • The flow velocity distribution at inlet and exit of Diesel Particulate Filter(DPF) by fabricating L-shape connector with the DPF was measured using a Pitot-tube and 2-D transverse machine. An adaptor designed for making the Pitot tube probe access to the inlet and exit of the DPF was connected with the inlet and exit flange of the DPF, respectively. The Pitot tube which was mounted in the 2-D positioning machine could access to the inlet and exit of the DPF through the rectangular window of the adaptor. The L-shape connector in the DPF inlet has a flow guide which is a perforated steel pipe. The flow velocity distribution at the inlet of the DPF showed a chaotic velocity distribution which is different from that with a diffuser type connector. The velocity distribution at the exit of the DPF showed a crown shape which is similar to that of the diffuser type connector. The velocity distribution at the exit of DPF showed different patterns according to the air flow rate.

Study on Measurement of Flow Distribution for Design of Room Air Conditioner with High-Efficiency (고효율 룸 에어컨 설계를 위한 유동 분포 측정에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.853-856
    • /
    • 2009
  • Test models which have geometrical similarities with a real room air conditioner (RAC) have been manufactured including visualization windows so that a laser beam can pass through a cross flow fan. Then, flow distributions of the RAC have been investigated using a visualization technique such as a Particle Image Velocimetry (PIV) to analyze an efficiency and noise of the RAC. Pitot tubes have also been used to measure the flow velocity inside the RAC with various positions to confirm the measurement accuracy of the PIV technique. The measured flow velocities have been analyzed and new designs of the RAC have been proposed to improve the efficiency and to reduce the noise for the RAC in this study.

  • PDF

An Experimental Study for Flow Characteristics Inside the Rotor of a Multiblade Fan/Scroll System (다익 팬/스크롤 시스템의 로터 내부 유동 특성에 관한 실험적 연구)

  • Maeng, Joo-Sung;Yoon, Joon-Yong;Ahn, Tae-Beom;Yoon, Jong-Eun;Hahn, Doug-Jeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.646-652
    • /
    • 1999
  • Detailed characteristics of the mean flow field inside the rotor of a multiblade fan with scroll are presented in this paper by measurements and visualizations. The measurements were taken with a five-hole probe and conformed by smoke test. How field is distinguished clearly in 3 regions with respect to the flow directions. The first region is near the exit of scroll where the fluid flows the opposite direction to the rotation of rotor. The second is opposite side of the scroll exit where the fluid flows the same direction to the rotation of rotor. The third is the region where the fluid flows toward the blades directly with the largest values comparatively. The strongest recirculation is happened in the second region, and the weakest one is in the third region. This complex configuration makes the flow field highly non-uniform and may cause to generate a noise and ineffective flow efficiency.

An Experimental Study of Test Section Velocity Calibration for Low-Speed Wind Tunnel (저속풍동 시험부 속도교정에 관한 실험적 연구)

  • Oh, Se-Yoon;Lee, Jong-Geon;Kim, Sung-Cheol;Kim, Sang-Ho;Ahn, Seung-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.230-236
    • /
    • 2012
  • The purpose of this research is to determine the calibration constants of the wind speed measurement systems required to calculate the wind tunnel velocity in the test section. In the present work, the aerodynamic calibration tests of the test section were conducted in the Agency for Defense Development's Low-Speed Wind Tunnel. The test speed ranged from 10 to 100 m/s with a reference pitot-static pressure probe. The validity of the calibration results was evaluated by comparing them with the previous calibration constants. The calibration results show that fair to good agreement is obtained with resonable accuracy.