• Title/Summary/Keyword: 피뢰

Search Result 330, Processing Time 0.046 seconds

Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions (외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화)

  • Lee, Seung-Ju;Lee, Su-Bong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.62-68
    • /
    • 2008
  • This paper describes the electrical characteristics of ZnO surge arresters associated with the variation of surrounding conditions. To investigate the deterioration behaviors of ZnO surge arresters due to lightning surges, 8/20[${\mu}s$], 2.5[kA] impulse currents were injected to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester subject to power frequency AC voltage were measured in different surrounding temperature and wet conditions. As a result, it was found that the leakage current is increased and its asymmetry is pronounced as the number of injection of the impulse current and the ambient temperature increase. Also, in the wet test the outside leakage current flowing through the housing surface of the ZnO surge arrester is much larger than the intrinsic leakage current of ZnO surge arrester element. The results obtained in this work can be a lied as factors of improving the reliability and performance of monitoring system for surge arresters.

Development of Longtime Reliability Assessment Method of Polymer Housed Distribution Surge Arresters using Accelerated Aging Test (가속열화시험을 이용한 배전용 폴리머피뢰기의 장기신뢰성 평가기법 개발)

  • Kim, Ju-Yong;Song, Il-Keun;Moon, Jae-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.141-150
    • /
    • 2006
  • In this study we developed accelerated aging test cycle and equipment which can simulate domestic weather condition. And we proposed long term reliability assessment method for polymer housed distribution surge arresters. We carried out electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test. Through the analysis we verified the capability of the proposed method and we presented characteristic data for maintenance of domestic arresters.

Type Test Method and Result Study of 345kV Transmission Line Arresters with External Gap (345kV 송전선로용 피뢰기 규격시험 방법 및 결과 고찰)

  • Jeong, Moon-Gyu;Kwak, Joo-Sik;Woo, Jung-Wook;Han, Ki-Seon;Goo, Sun-Geun;Ju, Hyoung-Jun;Oh, Seung-Ryle;Kim, Hyun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.402-403
    • /
    • 2015
  • 송전선로에 피뢰기 적용은 현재까지 알려진 여러 내뢰 대책 중 기술적으로 가장 우수한 방법으로 알려져 있어 향후에도 지속적으로 확대적용이 예상된다. 송전선로용 피뢰기는 변전소에 설치되는 피뢰기와는 달리 영구 고장시에도 운전이 가능한 갭형 타입을 채용하고 있는 것을 특징으로 한다. 본 논문에서는 345kV 송전선로의 2회선 동시고장 예방을 위해 개발된 송전선로용 피뢰기의 주요 규격시험 방법과 최근에 수행된 시험 결과에 대해 논하고자 한다. 규격시험은 내부특성소자, 본체, 설치장치, 부속재에 대해 시행되며 기본적으로 IEC 규격을 준용한다.

  • PDF

A Study on The Scheme for Omission of lightning Arresters on One-Phase and Overhead Ground Wires in the Power Distribution Lines (배전선 1상의 피뢰기 및 가공지선 생략 방안 연구)

  • 정현수;정창호;김진오;송일근;장완성
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2001
  • This proper presents the characteristics and their schemes for omission of lighting arresters on one-phase and over-head ground wire in the power distribution line. The case studies for Japan were investigated and compared with the cases of Korea. Especially, the EMTP simulation was performed for the omission scheme of lightning arrester's middle phase and the simulation results were described on the feasible problems when omitted. In this paper, it could be concluded that the omission of ground wire may be possible in some cases for the omission of lightning arresters, and in that case, the capacity of the lightning arresters should be Increase.

  • PDF

배전용 폴리머 피뢰기의 장기 신뢰성 평가 기술

  • 권태호;송일근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.44-51
    • /
    • 2004
  • 오늘날 대부분의 에너지를 전기에 의존함에 따라 전력사용이 급증하고 부하가 대용량화되어 및 정적 전력공급이 중요한 문제로 대두되었다. 이러한 추세에 따라 송ㆍ배전 설비도 점차 대용량화 및 고전압화 되고 신뢰성을 요구하게 되며, 각종 배전 설비의 제조기술이 더욱 복합 다양하게 발전하고 있다. 그 중 전력계통에서 뇌 혹은 개폐서지 등의 과전압을 흡수ㆍ억제하여, 전력설비와 계통보호를 위해 설치하는 것이 피뢰기이다. 따라서 어떻게 과전압을 낮게 억제할 수 있을까 하는 것이 피뢰기의 가장 중요한 성능이라고 말할 수 있다. (중략)

  • PDF

A Study on the Submergence Test of the Distribution Polymer Surge Arrester (침수시험에 의한 비전용 폴리머피뢰기의 특성연구)

  • Kim, Ju-Yong;Kwon, Tae-Ho;Song, Il-Keun;Lee, Jae-Bong;Kim, Dong-Myung;Jeong, Yeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.104-106
    • /
    • 2003
  • 본 논문은 이상전압으로부터 배전선로 및 전력기기를 보호하기 위해 사용되는 폴리머피뢰기에 대해 침수 시험을 실시하여 침수 전후 폴리머피뢰기의 특성변화를 평가하였다. 침수 시험은 수온 95[$^{\circ}C$]에서 20일 동안 실시하였다. 침수 시험 전후 폴리머피뢰기의 특성분석은 푸리에변환 적외선분광기(FTR : fourier transform infrared spectrophotometer), 유전열분석(DETA : dielectric thermal analyzer), 발수성 측정, 절연저항 측정, 누설전류 측정, 동작개시전압 측정 둥으로 연구 하였다. 이를 통해 침수시험의 열화 효과에 대해 검토하였다.

  • PDF

Lightning overvoltage analysis of 500 kV GIS S/S for BIL selection (500 kV 개스절연변전소의 BIL 결정을 위한 뇌과전압 해석)

  • Ju, H.J.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.326-328
    • /
    • 2005
  • 500kV 개스절연 변전소의 절연협조의 기본은 이상전압의 억제와 동시에 설비의 중요도, 적용형태를 고려하여 설비의 사고확율을 어떤 허용수준이하가 되도록 기기의 절연 강도와 배치를 결정하는 것이다. 일반적으로 변전소 뇌과전압에 영향을 미치는 요소로는 모선 형태 및 구성, 피뢰기의 위치와 설치대수, 피뢰기의 제한 전압-전류특성, 모선의 길이, 피뢰기와 피보호기간의 이격거리 등이 있다. 이 논문에서는 500kV의 개스절연변전소의 기기 절연강도 결정을 위하여 뇌침입시 변전소의 뇌과전압을 EMTP로 모의하여 뇌격의 크기, 뇌격지점, 피뢰기위치와 설치 대수, 등에 따른 최대과전압을 모의하여 BIL(basic inpulse level)을 선정하였다.

  • PDF

An Assessment of Distribution Class Polymer Arresters used in Field (현장에서 사용한 배전용 폴리머피뢰기의 특성 평가)

  • Lee, J.B.;Song, I.K.;Lee, B.S.;Park, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.600-602
    • /
    • 2005
  • 국내 배전계통에 90년대 말부터 설치된 폴리머피뢰기를 발취하여 신품과 비교 시험을 하였다. 시험결과 현장 경년품에서 부분방전, 내열화성 시험, 절연행거의 특성 시험 둥에서 다수의 시료가 불량한 결과를 나타냈다. 이러한 평가결과 국산 폴리머피뢰기의 품질이 안정화되지 않고 있어 배전계통의 신뢰성을 저하시킬 우려가 있다. 이러한 결과를 바탕으로 한전에서는 폴리머 피뢰기의 품질인증 기준을 강화하여 이를 구매규격서에 반영하였다.

  • PDF