• Title/Summary/Keyword: 피로캡슐

Search Result 3, Processing Time 0.016 seconds

자가치료용 마이크로캡슐의 박막 특성 증진 연구

  • 소진호;윤성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.96-96
    • /
    • 2004
  • 고성능 섬유강화 복합재는 비강성과 비강도가 높고 내부식성과 피로특성이 우수하지만 외부에서 가해지는 하중에 의해 수지, 강화섬유와 수지와의 경계면, 적층 경계면 등에 육안으로 식별하기 어려운 손상이 유발될 가능성이 있으며 이로 인해 구조재로서의 역할을 하지 못하는 경우가 발생한다. 최근에는 외부하중으로 인해 복합재 구조재에 손상이 발생한 경우 자가치료제가 저장된 마이크로캡슐을 이용하여 손상을 보수하려는 시도가 행해지고 있다.(중략)

  • PDF

Preparation of Fragrant Microcapsule for Reducing Stress (긴장완화를 위한 향기나는 마이크로캡슐의 제조)

  • Kim, Yoon A;Kim, So Hyun;Park, Ji Su;Lee, Da Som;Kim, Jin Gon;Shin, Jae Sup
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • A fragrant microcapsule was prepared for use by students to reduce the stress of taking examinations. Rosmarinic acid was used as a fragrant oil which had the effect of relaxing stress, polycaprolactone (PCL) was used as a capsule wall material, and poly(vinyl alcohol) (PVA) as a stabilizer. The solvent evaporation method was used to form the microcapsule. The microcapsules were prepared by changing the stirring rate, the concentration of the stabilizer, and the molecular weight of PCL. The shape of the microcapsule was characterized by scanning electron microscopy (SEM). The size of the microcapsule was reduced by increasing the stirring speed. The release rate of rosmarinic acid was decreased when the higher molecular weight PCL was used. When the prepared microcapsule was tested in an aromatherapy class, the microencapsulated fragrant oil had a longer release time than the original fragrant oil. The study data showed that this fragrant oil was effective for increasing concentration ability, reducing stress, increasing digestive power, and increasing memory for the students.

Performance Tests and Development of the Cyclic Load Device Using a Bellows (벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험)

  • Choi, Myoung-Hwan;Cho, Man-Soon;Park, Sung-Jae;Kim, Bong-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.903-909
    • /
    • 2007
  • A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.