• Title/Summary/Keyword: 플라즈마 풍동시험

Search Result 6, Processing Time 0.024 seconds

Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험)

  • Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.527-528
    • /
    • 2012
  • DBD (Dielectric Barrier Discharge) plasma actuator was designed for aerodynamic drag reduction using plasma flow control, and the drag reduction was measured by wind-tunnel tests using 2D test model. At the zero wind velocity, the plasma flow control had no effect on the drag reduction because the flow separation and surface friction drag were not occurred. At the wind velocity of 2m/s, 9.7% of drag was reduced by the flow separation control. The drag reduction decreased as the wind velocity increased.

  • PDF

전북대학교 플라즈마 풍동용 0.4 MW 분절형 아크 플라즈마 발생 장치 구축

  • Lee, Mi-Yeon;Seo, Jun-Ho;Kim, Jeong-Su;Choe, Chae-Hong;Kim, Min-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.539-539
    • /
    • 2012
  • 전북대학교 고온플라즈마 응용연구센터는 교육과학기술부 기초연구사업 중 고가연구장비 구축사업의 일환으로, 고 엔탈피, 초음속 유동 환경을 모사하여, 항공우주, 군사기기, 핵융합 분야 등의 고온 재료 개발을 위한 기초 연구 장치로써, 0.4MW급 플라즈마 풍동 장치를 구축하고 있다. 0.4MW 플라즈마 풍동 장치의 플라즈마 발생부는 DC 전원 공급장치와 디스크 형태의 양극과 음극 사이에 동일 형태의 간극을 삽입한 0.4MW급 분절형 아크 플라즈마 토치로 구성되었으며, 토치에서 발생된 아크 플라즈마는 노즐을 통과하며 마하 2~4의 초음속을 나타내도록 설계 제작되었다. 시험 챔버는 노즐에서 나온 초음속 플라즈마의 특성 및 재료 시험을 위한 3차원 이송식 기판이 장착되어 있으며, 고 엔탈피 유동을 관측하기 위한 광학창을 구비하였다. 시험 챔버 하류에는 유동 안정을 위한 디퓨저(diffuser)가 설치되어 있으며, 디퓨저(diffuser)로부터 배출되는 고온가스는 열교환기를 통해 냉각된 후 진공펌프를 통해 대기로 배출되게 된다. 장치의 압력조절을 위하여 $1,000m^3/min$의 용량의 진공펌프 시스템이 설치될 예정이며 가스공급장치, 냉각수 공급장치, 디퓨져, 열교환기는 1MW급 용량으로 설계 제작되었다. 본 장치는 400kW의 전원 공급, 15 g/s의 공기유량 주입 시 약 13 MJ/kg의 고엔탈피를 가진, mach 2~4의 초음속 유동을 나타내는 것을 특징으로 한다.

  • PDF

Aerodynamic Drag Reduction in Cylindrical Model Using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 원통모델의 공기저항저감)

  • Lee, Changwook;Sim, Ju-Hyeong;Han, Sunghyun;Yun, Su Hwan;Kim, Taegyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • Dielectric barrier discharge (DBD) plasma actuator was designed to reduce aerodynamic drag in a cylindrical model and wind tunnel test was performed at various wind velocities. In addition, computational fluid dynamics (CFD) analysis and flow visualization were used to investigate the effect of the plasma on the flow stream in the cylinderical model. At low wind velocity, the plasma actuator had no effects because flow separation did not appear. The aerodynamic drag was reduced by 14% at 14 m/s and by 27% at 17 m/s, respectively. It was confirmed by CFD analysis and flow visualization that the DBD plasma actuator decreased in pressure difference around the cylindrical model, thus decreasing the magnitude of wake vortex.

A Study on Improvement of the Ablation Resistance of Two Types of the Carbon/Carbon Composites by HfC Coating (하프늄카바이드 코팅을 통한 2종형상의 탄소/탄소복합재의 내삭마성 향상연구)

  • Kang, Bo-Ram;Kim, Ho-Seok;Oh, Phil-Yong;Choi, Seong-Man
    • Composites Research
    • /
    • v.33 no.4
    • /
    • pp.205-212
    • /
    • 2020
  • In this study, HfC was coated on two types of carbon/carbon composites coated with SiC by vacuum plasma spraying(VPS). The experiment was performed using a plasma wind tunnel with heat flux of 5.06 MW/㎡ for 120 s heat flux before and after the coating. The mass ablation rate was calculated through the mass change before and after the test, and the length change was measured by using calipers and high speed camera. The oxidation/ablation behavior were observed by FE-SEM with EDS analysis of the specimens cross section. The plasma wind tunnel test results showed that the coated specimens had low weight loss and length change, and high oxidation/ablation resistance. However, two types of the specimens tested under the same conditions were different in the ablation behavior and ablation rate, and it was evaluated that the cylindrical type had higher oxidation/ablation resistance.

Site Plan of High-enthalpy Plasma Research Center in Chonbuk National University (전북대학교 고온플라즈마응용연구센터 Site Plan)

  • Kim, Min-Ho;Choi, Seong-Man;Seo, Jun-Ho;Choi, Chea-Hong;Hong, Bong-Guen
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.764-767
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction for MW class plasma wind tunnel. Four types of plasma equipment will be installed in the research center. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma equipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. And electrical, water and gas utilities to assistant plasma equipments are under construction. The research center consists of experiment building, research building, power supply building, air supply building, cooling tower foundation.

  • PDF

A Study on Surface Properties of Ablative Materials from 0.4MW Arc-Heated Wind Tunnel Test (0.4MW 아크 가열 풍동 시험을 통한 삭마 재료의 표면 특성 연구)

  • Kim, Nam Jo;Oh, Philyong;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1048-1053
    • /
    • 2015
  • Ablative materials in a thermal protection system for atmospheric re-entry suffers from the most severe heat fluxes and temperatures, which induces surface recession in the thickness direction. In this paper, a 0.4MW arc-heated wind tunnel is operated to test for ablative materials, and a non-contact three-dimensional surface measuring system is used to evaluate the different surface characteristics of them. In particular, by postprocessing the three-dimensional image data, the surface roughness and recession of ablative materials can be calculated before and after the wind tunnel test. Moreover, the surface properties are analyzed quantitatively by comparing volume and mass losses of the test specimens.