• Title/Summary/Keyword: 플라즈마 평면 표시기

Search Result 1, Processing Time 0.02 seconds

PIV Measurement on the Flows of PDP(Plasma Display Panel) (PDP 유동장 PIV 계측)

  • Doh, D.H.;Cho, G.R.;Pyun, Y.B.;Song, J.S.;Baek, T.S.;Jung, W.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.733-737
    • /
    • 2001
  • Heat generated from the electronic parts in PDP is undesirable physical properties. To attain optimal arrangement of the electronic parts in PDP, thermal flows in PDP should be analyzed. PIV measurement has been made to quantify the characteristics of the inner flows and outer flows of an actual PDP. The quantity of heat flux from PDP has been estimated using the PIV results. Measurement system consists of Ar-ion laser, CCD camera and an image grabber installed on a host computer.

  • PDF