• Title/Summary/Keyword: 플라스틱 광섬유

Search Result 75, Processing Time 0.026 seconds

INFECTION CONTROL OF LIGHT CURING UNITS (광중합기 사용 시의 감염 조절)

  • Chang, Hoon-Sang
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.235-237
    • /
    • 2010
  • When curing the composite restorations with light curing units, the light guides are often in direct contact with oral tissues, therefore contamination of light guides is inevitable. Curing light guides fall into the "semicritical" instrument category according to the Centers for Disease Control and Prevention (CDC) and must be heat or vapor-sterilized or at a minimum, these semicritical instruments must be sterilized in a liquid chemical agent. Currently, most common methods of maintaining sterility of the light guides are wiping the guide with a disinfectant, such as glutaraldehyde, after each patient use; using autoclavable guides; using presterilized, single-use plastic guides; and using translucent disposable barriers to cover the guide.

Development of an Organic Scintillator Sensor for Radiation Dosimetry using Transparent Epoxy Resin and Optical Fiber (투명 에폭시와 광섬유를 이용한 방사선량 측정용 유기섬광체 센서 개발)

  • Park, Chan-Hee;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.87-92
    • /
    • 2009
  • Remote detecting system for a radiation contamination using a plastic scintillator and an optical fiber was developed. Using a commercially available silica optical fiber and a plastic scintillator, we tested then for a real possibility as a remote monitoring detector. Also, a plastic scintillator was developed by itself, and evaluated as a radiation sensor. The plastic scintillator was made of epoxy resin, a hardener and an organic scintillation material. The mixture rate of the epoxy resin, hardener and organic scintillator was fixed by using their emission spectrum, transmittance, intensity etc. In this study, in order to decrease the light loss of an incomplete connection between an optical fiber and a scintillator, the optical fiber was inserted into the scintillator during the fabrication process. The senor used a plastic optical fiber and was estimated for its detection efficiency by an optic fiber's geometric factor.

  • PDF

Fabrication and Characteristics of Optical Connector/Optical Transceiver for Plastic Optical Fiber (플라스틱 광섬유용 광커넥터/광송수신모듈 제작과 특성)

  • Ahn Jung-Gyun;Park Kyoung-Seo;Park Min-Sung
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.346-348
    • /
    • 2003
  • 본 논문에서는 플라스틱 광섬유용(POF) 광커넥터와 광송수신모듈을 설계. 제작하여 특성을 평가하였다. 650nm와 850nm POF 광커넥터는 광학적, 기계적, 환경적 신뢰성 시험을 통해 안정성을 확증할 수 있었다. POF 광송수신모듈은 1.25Gbps와 155Mbps급의 SC, RJ-45 형태의 구조로 제작되었고, 이를 적용하여 S/W Hub 및 광전 Outlet, Media Converter등을 구현하였다.

  • PDF

A Study on the Bundle-type Scintillating Fiber and Tapered Scintillator Radiation Sensors for Monitoring of Radioactive Wastes Disposal Sites (방사성폐기물 처분장 감시를 위한 다발형 광섬유 센서 및 Tapered 섬광체 방사선 센서에 관한 연구)

  • 김계홍;박재우
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.233-238
    • /
    • 2003
  • Several types of gamma-ray sensors were constructed by packing different numbers of fibers into aluminum tubes, and tested to detect the $^137Cs$ gamma ray. It has been found from this investigation that tapered fibers can be more efficient to collect the lights produced inside the sensor and transfer them into the transmitting fiber in order to predict the functioning of the tapered fiber, tapered plastic scintillators, composed of polystyrene with minute amount of dPOPOP and PPO or dPBD, were fabricated and tested for the detection of gamma rays from 1.0 1.5 3.0 5.0 ${\mu}Ci$ $^137Cs$ sources, and the pulse hight spectrum and the relationship between the radioactivity and the total counts are analyzed. It has been found from this study that the tapered scintillating optical fiber, if manufactured, can be practically applied to the development of gamma-ray sensors which can be deployed In ${\mu}Ci$-level radiation fields

  • PDF

Sensor Mat using POF for Medical Application (의료용 플라스틱 광섬유 센서 매트)

  • Choi, Kyoo-Nam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.74-78
    • /
    • 2007
  • Novel concept of sensor mat and its signal processing method is proposed for patient monitoring in medical application. Proposed sensor mat structure has sensing inner layer which has cross-linked arrangement using plastic optical fiber(POF). Large core diameter of plastic optical fiber behaved as band pass filter by averaging the noise component caused by unwanted environmental factors. Signal processor followed by sensor output added noise immune performance by filtering out unwanted component. Fail-proof patient breath monitoring scheme was realized by using intelligent decision algorithm. Unlike the conventional approach by using mechanical sensor, which have high sensitivity both to signal and to environmental noise, our approach provided reliable breath motion detection.

SNR Improvement in A Wireless Optical Differential Detector Using Plastic Fibers (플라스틱 광섬유를 이용한 무선광 차동검출기의 신호대잡음비 개선)

  • Lee Seong-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.410-417
    • /
    • 2005
  • In this paper, optical noise is reduced by a differential detector with a plastic optical fiber bundle in a wireless optical interconnection. A plastic optical fiber bundle divides the received optical signal equally and connects it to two photodiodes. In this configuration two photodiodes effectively detect the optical signal at one point, and the output voltage variation due to the abrupt change of optical noise distribution in space disappears. The signal to noise ratio in a differential detector with a fiber bundle was improved to be $10\;\cal{dB}$ higher than in a single photodiode with an optical filter.