• 제목/요약/키워드: 풍소음

Search Result 52, Processing Time 0.033 seconds

Analysis and Mitigative Countermeasures of Wind Noise from Transmission Line (송전선로 풍소음 발생 원인분석 및 저감대책)

  • Sim, Soon-Bo;Min, Byeong-Wook;Kim, Sae-Hyun;Lee, Dong-Il;Shin, Gu-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.35-37
    • /
    • 2002
  • Most of the inhabitants living near power line complain wind noise from power line to be problems they can feel directly if there is no countermeasure to remove noise basically. Wind noise from power line happens by tower, insulators, conductor and others in their operating individually or complexly. Wind noise show us several forms like whistle, siren and bullfrog croaking as height of noise source is high and elastic wave tone with low frequency. This paper shows actual conditions and occurrence cause which may be investigated and analyzed on the wind noise, and also prepares mitigation methods and introduces a working sample to reduce a wind noise.

  • PDF

A study on the wind noise from transmission line and mitigation methods (송전선로에 의한 풍소음 발생 저감 기법)

  • Shin, K.Y.;Lee, D.I.;Yoon, J.Y.;Oh, C.H.;Kim, S.H.;Kim, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2143-2145
    • /
    • 1999
  • Measurements of wind noise, generated by High-voltage overhead transmission lines placed in a uniform flow are carried out in the Anechoic windtunnel. High-voltage overhead transmission lines generates audible wind noise, which cause a serious environment problem. Accordingly, wind noise has become one of major concerns for design engineers and operations personnel. In the present research, tests were mainly performed with various configuration of transmission line with spiral wires. Remarkable noise reduction was observed for some of the spiral transmission lines, compared with the noise generated without the spiral wire.

  • PDF

A Study on A Spiral Charge for 3 Dimensional Charge Simulation Method (3차원 전하 중첩법용 나선 전하의 특성에 관한 연구)

  • 민석원;박은서;송기현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.31-36
    • /
    • 2001
  • This paper investigates characteristics of spiral charge for 3 dimensional charge simulation method to calculate electric fields of special conductor bundles with spiral rods in 765kV transmission line. We finds the simulating spiral charge as constant charge density give less potential calculation error than sinusoidal charge falsity. When a spiral rod is simulated as spiral charge, we also knows two spiral charge can simulate spiral rod best.

  • PDF

Characteristics of wind noise on 765kV Transmission Line and countermeasure against wind noise (765 kV 송전선로의 풍소음 발생특성과 대책연구)

  • Lee, Dong-Il;Shin, Koo-Yong;Chu, Jang-Hee;Kim, Sang-Beom;Lee, Seong-Doo;Kim, Jeong-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2005-2007
    • /
    • 2000
  • KEPCO 765 kV Transmission Lines where seasonal winds intersect to the direction of the transmission line route cause aeolian complaints from residents near the transmission lines due to 1.5 times sub-conductors numbers and about 2 times of tower height comparing 345 kV transmission lines. To decrease the wind noise generation, KEPRI developed two countermeasures. One is to install the Spiral Rod on wired 765 kV Cardinal conductor. The other method is to wire the Low Noise conductor which has salient part on the surface.

  • PDF

A Study on the Soundproofing Plate Techniques for Noise Reduction of Power Transformers (전력용 변압기 소음저감을 위한 차음판 기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chon;Kim, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.47-55
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an enclosure to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. To shut out sound emitted from transformers, we developed a soundproof technology that wall up reinforcing bar by steel sheet. For the practical application of it, we analyzed the vibration characteristics of a transformer tank and reduction of noise according to soundproof plate. As a result, it is confirmed that the technology can reduce 11 [dB] of transformer noise.

Structural and Vibration Analysis of Large Windturbine Rotor Considering the Rotational and Aero Load Effect (회전 및 풍하중 가진 효과를 고려한 대형 풍력발전 로터의 구조 및 진동해석)

  • Kim, Dong-Man;Kim, Dong-Hyun;Park, Kang-Kyun;Kim, Yu-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.270-275
    • /
    • 2008
  • In this study, computer applied engineering (CAE) techniques are full? used to conduct structural and dynamic analyses of a huge composite rotor blade. Computational fluid dynamics is used to predict aerodynamic load of the rotating wind-turbine blade model. Static and dynamic structural analyses are conducted based on the non-linear finite element method for composite laminates and multi-body dynamic simulation tools. Various numerical results for aerodynamic load, dynamic analyses are presented and characteristics of structural behaviors are investigated herein.

  • PDF

Efficient Super-element Structural Vibration Analyses of a Large Wind-turbine Rotor Blade Considering Rotational and Aerodynamic Load Effects (회전 및 풍하중 가진 효과를 고려한 대형 풍력발전 로터의 효율적인 슈퍼요소 구조진동해석)

  • Kim, Dong-Man;Kim, Dong-Hyun;Park, Kang-Kyun;Kim, Yu-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.7
    • /
    • pp.651-658
    • /
    • 2009
  • In this study, computer applied engineering(CAE) techniques are fully used to efficiently conduct structural and dynamic analyses of a huge composite rotor blade using super-element. Computational fluid dynamics(CFD) is used to predict aerodynamic loads of the rotating wind-turbine blade. Structural vibration analysis is conducted based on the non-linear finite element method for composite laminates and multi-body dynamic simulation tools. Various numerical results are presented for comparison and the structural dynamic behaviors of the rotor blade are investigated herein.

A Study of Natural Frequency on Offshore Wind Turbine Structural Change (해상 풍력 발전용 구조물 변화에 따른 고유진동해석)

  • Lee, Kang-Su;Lee, Jung-Tak;Son, Choong-Yul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1008-1016
    • /
    • 2007
  • The purpose of this paper is to investigate the Natural Frequency behavior characteristic of Wind Turbine Tower model, and calculated the stress values of thrust load, wave load, wind load, current load, and gravity load. The offshore Jacket Type Tower which was installed in Vitenam South China Sea is used for the study. Natural frequency and mode shape are calculated with commercial program using the measured vibration. The finite element analysis is performed with commercial F.E.M program(ANSYS) on the basis of the natural frequency and mode shape.

  • PDF

Wind Load Induced Vibration Analysis for Tall Structure (고층건물의 풍하중 유발 진동해석)

  • Kim, Dong-Hyun;Kim, Yu-Sung;Kim, Yo-Han;Kim, Dong-Man;Kim, Jong-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.658-659
    • /
    • 2009
  • In this study, fluid-induced vibration (FIV) analyses have been conducted for tall building structure. In order to investigate the aeroelastic responses of tall building due to wind load, advanced computational analysis system based n computational fluid dynamics(CFD) and computational structural dynamics (CSD) has been developed. Fluid domains are modeled using the computational grid system with local grid deforming technique. A fully implicit time marching scheme based on the Newmark direct integration method is used for computing the coupled aeroelastic governing equations of tall structure for fluid-structure interaction (FSI) problems. Detailed aeroelastic responses and results are presented to show the physical phenomenon of the tall building.

  • PDF

Performance Evaluation of Laminated-Tempered Glass as a Component of Noise Barrier on Metro Railway Elevated Bridge Against Train Induced Vibration and Wind Load (지하철 고가교 접합강화유리 방음판의 열차진동 및 풍하중에 대한 성능평가)

  • Kim, Suk-Su;Lee, Ho-Beom;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.30-41
    • /
    • 2017
  • Types of noise barrier installed for noise attenuation are largely divided into noise-absorbing format and noise-proofing format. In these days, installation of transparent noise barrier is general trend to solve problems that hinder sunshine and landscape. Some kinds of transparent boards are used to one of components in noise barriers, but in some cases, less transparency and worse pollution due to yellowing phenomena, and severe material deformation are to harm the urban aesthetics Therefore laminated-tempered glass board in that yellowing phenomena does not occur can be replaced as a transparent one to secure those shortcomings. In this paper, the structural safety against train induced vibration and the resistibility to wind load are analyzed for laminated-tempered glass system as a component of noise barrier installed on Metro railway elevated bridges. Also the appropriateness is evaluated through flexural bending performance test, compressive strength test, modulus of elasticity tests, and impact test for the system or the glass material itself. All of these processes are intended to present the deployment of logic to evaluate the adequacy for the system.