• Title/Summary/Keyword: 표준편차$(\sigma)$

Search Result 44, Processing Time 0.026 seconds

A Comparison of Calibration Methods for the COCOMO II Post-Architecture Model (COCOMOII의 후구조 모델에 대한 캘리브레이션 방법 비교)

  • Yoon, Myoung-Young
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.05a
    • /
    • pp.135-143
    • /
    • 2000
  • The COCOMO Ⅱ model is well-suited for the new software development life cycle such as non-sequential and rapid-development processes. The traditional regression approach based on the least square criterion is the most commonly used technique for empirical calibration in the COCOMO Ⅱ model. But it has a few assumptions frequently violated by software engineering data sets. It is true that the source data is also generally imprecise in reporting size, effort, and cost-driver ratings, particularly across different organizations. And that the outlier for the source data is a peculiarity and indicates a data pint To cope with difficulties, in this paper, we propose a new regression method for calibrating COCOMO Ⅱ post-architecture model based on the minimum relative erro(MRE) criterion. The characteristic of the proposed method is insensitive to the extreme values of the data in the empirical calibration. As the experimental results, It is evident that our proposed calibration method MRE was shown to be superior to the traditional regression approach for model calibration, as illustrated by the values obtained for standard deviation(^σ), and prediction at level L PRED(L) measures.

  • PDF

An Improved Calibration Method for the COCOMO II Post-Architecture Model

  • Yoon, Myoung-Young
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.2
    • /
    • pp.47-55
    • /
    • 2000
  • To date many software engineering cost models have been developed to predict cost, schedule, and effort of the software under development. The COCOMO Ⅱ is well- suited for the new software development life cycle such as non-sequential and rapid- development processes. The traditional regression approach based on the least square criterion is the most commonly used technique for empirical calibration in the COCOMO Ⅱ model. It has a few assumptions frequently violated by software engineering data sets. The source data is also generally imprecise in reporting size effort, and cost-driver ratings, particularly across different organizations. And that the outlier for the source data is a peculiarity and indicates a data point. To cope with difficulties, in this paper, we propose a new regression method for calibrating COCOMO Ⅱ post-architecture model based on the minimum relative error(MRE) criterion. The characteristic of the proposed method is insensitive to the extreme values of the data in the empirical calibration. As the experimental results, It is evident that our proposed calibration method MRE was shown to be superior to the traditional regression approach for model calibration, as illustrated by the values obtained for standard deviation(^σ), and prediction at level LPRED(L) measures.

  • PDF

Automatic Method for Extracting Homogeneity Threshold and Segmenting Homogeneous Regions in Image (영상의 동질성 문턱 값 추출과 영역 분할 자동화 방법)

  • Han, Gi-Tae
    • The KIPS Transactions:PartB
    • /
    • v.17B no.5
    • /
    • pp.363-374
    • /
    • 2010
  • In this paper, we propose the method for extracting Homogeneity Threshold($H_T$) and for segmenting homogeneous regions by USRG(Unseeded Region Growing) with $H_T$. The $H_T$ is a criterion to distinguish homogeneity in neighbor pixels and is computed automatically from the original image by proposed method. Theoretical background for proposed method is based on the Otsu's single level threshold method. The method is used to divide a small local part of original image int o two classes and the sum($\sigma_c$) of standard deviations for the classes to satisfy special conditions for distinguishing as different regions from each other is used to compute $H_T$. To find validity for proposed method, we compare the original image with the image that is regenerated with only the segmented homogeneous regions and show up the fact that the difference between two images is not exist visually and also present the steps to regenerate the image in order the size of segmented homogeneous regions and in order the intensity that includes pixels. Also, we show up the validity of proposed method with various results that is segmented using the homogeneity thresholds($H^*_T$) that is added a coefficient ${\alpha}$ for adjusting scope of $H_T$. We expect that the proposed method can be applied in various fields such as visualization and animation of natural image, anatomy and biology and so on.

Extraction and Accuracy Assessment of Deforestation Area using GIS and Remotely Sensed Data (GIS와 원격탐사자료를 이용한 산림전용지 추출 및 정확도 평가)

  • Lee, Gihaeng;Lee, Jungsoo
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.365-373
    • /
    • 2012
  • This study purposed to extract and assess the accuracy of assessment for deforestation area in Wonju city using medium resolution satellite image. The total size of deforestation area during the last nine years (2000-2008) was about 467 ha, and it was occurred annually about 52 ha. The most frequent form of deforestation was settlements (72%). Ninety percent of the size of deforestation was less than 2 ha in size. In addition, 79 percent of deforestation area was found within 500 m from the road network and within 100 m of the Forest/Non-forest boundary. This study compared the deforestation based on the administrative information (GIS deforestationI) with the deforestation (RS deforestation) extracted from the satellite imagery by vegetation indices (NDVI, NBR, NDWI). Extraction accuracy, mean-standard deviation${\times}1.5$ applied 3 by 3 filtering, showed reliable accuracy 35.47% k-value 0.20. However, error could be occurred because of the difference of land-use change and land-cover change. The actual rate of land-cover change deforestation area was 32% on administrative information. The 7.52% of forest management activities area was misjudged as deforestation by RS deforestation. Finally, the comparison of land-cover change deforestation (GIS deforestationII) with the RS deforestation accuracy, as a result NDVI mean-standard deviation${\times}2$ applied 3 by 3 filtering, showed improved accuracy 61.23%, k-value 0.23.

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Studies on the Variation Pattern of Water Resources and their Generation Models by Simulation Technique (Simulation Technique에 의한 수자원의 변동양상 및 그 모의발생모델에 관한 연구)

  • Lee, Sun-Tak;An, Gyeong-Su;Lee, Ui-Rak
    • Water for future
    • /
    • v.9 no.2
    • /
    • pp.87-100
    • /
    • 1976
  • These studies are aimed at the analysis of systematic variation pattern of water resources in Korean river catchments and the development of their simulation models from the stochastic analysis of monthly and annual hydrologic data as main elements of water resources, i.e. rainfall and streamflow. In the analysis, monthly & annual rainfall records in Soul, Taegu, Pusan and Kwangju and streamflow records at the main gauging stations in Han, Nakdong and Geum river were used. Firstly, the systematic variation pattern of annual streamflow was found by the exponential function relationship between their standard deviations and mean values of log-annual runoff. Secondly, stochastic characteristics of annual rainfall & streamflow series were studied by the correlogram Monte Carlo method and a single season model of 1st-order Markov type were applied and compared in the simulation of annual hydrologic series. In the simulation, single season model of Markov type showed better results than LN-model and the simulated data were fit well with historical data. But it was noticed that LN-model gave quite better results in the simulation of annual rainfall. Thirdly, stochastic characteristics of monthly rainfall & streamflow series were also studied by the correlogram and spectrum analysis, and then the Model-C, which was developed and applied for the synthesis of monthly perennial streamflow by lst author and is a Markov type model with transformed skewed random number, was used in the simulation of monthly hydrologic series. In the simulation, it was proved that Model-C was fit well for extended area in Korea and also applicable for menthly rainfall as well as monthly streamflow.

  • PDF

Fabrication of FBAR (SMR) using Reflector (반사층을 이용한 FBAR(SMR)의 제조)

  • Lee, Jae-Bin;Kwak, Sang-Hyon;Kim, Hyeong-Joon;Park, Hee-Dae;Kim, Young-Sik
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1263-1269
    • /
    • 1999
  • An FBAR(Solidly Mounted Resonator) was fabricated using reflector layers which prohibit the penetration of bulk acoustic wave into substrate. The SMR consisted of top and bottom electrodes(Al films), a piezoelectric layer (ZnO film), reflector layers(W/$Si_2$ films) and Si substrate. The electrodes were deposited by dc sputtering. The piezoelectric layer and the reflector layers were deposited by rf magnetron sputtering. The control of crystallinity, microstructures and electric properties of each layer was essential for attaining the optimum FBAR characteristics. Under the best deposition conditions for FBAR devices, the ZnO films had highly c-axis preferred orientation(${\sigma}=2.17^{\circ}$), resistivity of $10^4\;{\omega}cm$, and surface roughness of 10.6 ${\AA}$. On the other hand, the surface roughness of W and $Si_2$ films was 16 ${\AA}$ and 33 ${\AA}$, respectively, and the resistivity of Al film was $5.1{\times}10^{-6}\;{\Omega}cm$. The SMR devices were fabricated by the conventional semiconductor processes. In the resonance conditions of the SMR, the series resonance frequency (fs) and the parallel resonance frequency(fp) were 1.244 GHz and 1.251 GHz, respectively and the quality factor(Q) was 1200.

  • PDF

Estimation of Ultimate Lateral Resistances of Piles Using CPT Cone Resistance in Sand (사질토지반에서 콘관입저항치 $q_c$에 의한 단말뚝의 극한수평단위지지력 평가)

  • Kim, Min-Kee;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.71-77
    • /
    • 2008
  • In this study, CPT-based methodology for estimating the ultimate lateral resistance, $p_u$, is proposed and verified for lateral loaded piles in sandy soil. Preexistent methods estimating the ultimate lateral resistance, $p_u$, and the ultimate lateral capacity, $H_u$, of pile have been based on the vertical effective stress, relative density, and the coefficient of lateral earth pressure. Similarly, cone resistance $q_c$ in pure sandy soil is expressed by those essential factors. As correlation between $p_u$ and $q_c$ are normalized with average effective stress ${\sigma}_m$, estimation methodology for the lateral loaded pile of $p_u$ in sandy soil is proposed. The method is verified by calibration chamber test results in pure sand. The standard derivation of estimated $p_u$ is 0.279, and COV (Coefficient Of Variation) of estimated $p_u$ is 0.272. These results showed that the estimated pus by the method are analogous with the measured $p_us$ in calibration chamber test.

Determination of aromatic amino acids by chemiluminometric assay with Luminol-H2O2-Cu(II) system (Luminol-H2O2-Cu(II) 시스템을 이용한 방향족 아미노산의 화학발광법적 정량)

  • Kim, Kyung-Min;Kim, Young-Ho;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.171-177
    • /
    • 2012
  • A determination method of aromatic amino acids such as trytophan (Trp), tyrosine (Tyr), and phenylalanine (Phe) using luminol-$H_2O_2$-Cu(II) system has been presented. In the presence of an aromatic amino acid, the enhanced chemiluminescence (CL) intensity of luminol-$H_2O_2$-Cu(II) system was obtained by forming a complex between Cu(II) and the amino acid. Based on the above phenomenon, a sensitive and fast determination of three aromatic amino acids was performed using the CL method in batch-type detection system. To optimize determination conditions, the kinetic influence of an aromatic amino acid on the luminol-$H_2O_2$-Cu(II) system and the effects of $H_2O_2$ and Cu(II) concentration, pH, and buffers were investigated. Under the optimized conditions, the calibration curve was linear over the range from $1.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Trp, $1.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Try, and $2.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Phe, respectively. In this range, reproducibility (RSD, n = 4) of Trp, Try, and Phe were 3.21%, 2.64%, and 2.48%, respectively. The limit of detection ($3{\sigma}/s$) was calculated to be $6.8{\times}10^{-7}\;M$ for Trp, $5.7{\times}10^{-7}\;M$ for Try, and $9.6{\times}10^{-7}\;M$ for Phe.