• Title/Summary/Keyword: 표준시료

Search Result 1,097, Processing Time 0.027 seconds

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Measurement of Radon Daughters' Radioactivities by Using Single Filtering Method (단일집진법(單一集塵法)에 의(依)한 라돈 붕괴생성물(崩壞生成物)의 농도측정(濃度測定))

  • Chang, Si-Young;Ro, Seung-Gy;Hong, Jong-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 1981
  • A measurement has been made for the radioactivities (or concentrations) of radon daughters, i.e., RaA, RaB and RaC in airborne dust by means of single filtering method. This is to evaluate the radioactivities in terms of Ci or WL (working level) from gross alpha counts measured in the selected-time intervals after an air sample is taken from a membrane filter paper with a mean pore size of $0.8{\mu}m$. This work involves determinations of standard deviation in radioactivities, radioactive equilibrium factor and ratio. It appears that a concentration of total radon daughters is $0.30{\sim}2.36pCi/l\;or\;0.89{\times}10^{-3}{\sim}6.57{\times}10^{-3}WL$, depending on the sampling time. Generally the highest concentration was observed around nine o'clock in a day while the lowest value was obtained around seventeen o'clock. Standard deviations based on counting statistics of RaA's, RaB's and RaC's concentrations are ${\pm}57.75%,\;{\pm}22.32%\;and\;{\pm}31.29%$, respectively. It is revealed that the radioactive equilibrium factor is 0.322 while the radioactive equilibrium ratio is of pattern $C_1>C_2>C_3$ in general. Here $C_1,\;C_2\;and\;C_3$ stand for concentrations of RaA,RaB and RaC, respectively.

  • PDF

Ultrasensitive Enzymeimmunoassay for Testosterone in Human Saliva (사람 타액내 Testosterone의 초감도 효소면역측정법)

  • 윤용달;전은현;이창주;도병록;이준영
    • Development and Reproduction
    • /
    • v.4 no.1
    • /
    • pp.115-123
    • /
    • 2000
  • A few enzymeimmunoassay (EfA) for testosterone (T) have been reported but was not suitable for all biological samples. The present study was designed to develop a rapid, ultrasensitive EIA and to apply this technique for study the physiological changes of T in biological samples. Saliva samples were collected at 06:00~09:00 hour during one menstrual cycle from 18 normally menstruating women and on 09:00~10:00 hour from 20 normal men. The present study shows an established EIA for testosterone, using horseradish peroxidase (HRP), which was covalently bonded to testosterone-3-carboxymethyloxime (T-3-CMO). One batch of T-antisera was also covalently linked to microcrystalline cellulose particles by a mixed anhydride method in order to facilitate separation of bound and free steroids. The established EIA was validated in terms of sensitivity, accuracy, specificity, precisions etc., comparing with conventional radioimmunoassay. The sensitivity of the established EIA was less than 25 pg/tube. The correlation coefficients between the expected T-values and observed T-values measured by EIA or RIA were r=0.985 and r=0.941 respectively. The cross reactivity of antiserum in EIA was a little higher than that of RIA, especially by 5 ${\alpha}$-DHT. The intra- and inter-assay precisions of the present EIA were similar to those of RIA. The present study also demonstrates that the normal T-values in saliva of Korean male & female samples are 265.65${\pm}$15.80 pmol/l and 109.74${\pm}$ 12.01 pmol/l, respectively. The present EIA seems to be established and suitable for use in the endocrinological studies. The advantages of this EIA system also might make the present T-EIA an ideal procedure for use in a routine assay of ordinary laboratory with a conventional spectrophotometer.

  • PDF

Simultaneous Separation and Determination of $^{l4}C\;and\;^3H$ in Spent Resins from PWR Nuclear Power Plants (가압경수로형 원전에서 발생된 폐수지의 $^{14}C$$^3H$ 동시 분리 및 측정)

  • Park, Soon-Dal;Kim, Jung-Suck;Kim, Jong-Goo;Han, Sun-Ho;Jee, Kwang-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.179-188
    • /
    • 2007
  • In this work $^{14}C\;and\;^3H$ distribution characteristics of spent resins from nuclear power plants(NPPs), pressurized water reactors(PWRs), was investigated. It was found that the recovery percent of $^{14}C$ by the wet oxidation-acid stripping was $81%{\sim}100%$ for the added activity range of $^{14}C,\;0.72\;Bq{\sim}460\;Bq$, and it was not affected by the kinds of stripping acids, 3N-HCl, $3\;N-HNO_3\;and\;3\;N-H_2SO_4$. And the recovery percent of $^3H$ by distillation using the same apparatus was $81%{\sim}101%$ for the added activity range of $^3H,\;0.60\;Bq{\sim}435\;Bq$. Among the tested stripping acids, 3\;N-HCl, $3\;N-HNO_3\;and\;3\;N-H_2SO_4$, only the trapped $^3H$ solution by distillation in $3\;N-H_2SO_4$ was compatible with the 3H scintillator, Ultimagold XR. Neither of the $^{14}C\;and\;^3H$ trapping solutions from the spent ion exchange resin samples by the wet oxidation-3 $N-H_2SO_4$ stripping contained gamma nuclides. However, some gamma nuclides, $^{60}Co,\;^{134}Cs,\;^{137}Cs\;and\;^{54}Mn$, were found in the trapped $^3H$ solutions of the spent resins by the wet oxidation-3 N-HCl stripping. It was the same for the $^3H$ trapping solutions of the spent resins by Sample Oxidizer(PACKARD MODEL 307). Meanwhile only two nuclides, $^{134}Cs,\;and\;^{134}Cs$, were found in the $^{14}C$ trapping solutions of the spent resins by Sample Oxidizer(PACKARD MODEL 307). It was found that most of the $^{14}C$ in the spent resins existed as inorganic carbon form, more than about 70% of the total $^{14}C$ content. Among the analyzed 30 spent ion exchange resin samples, the average concentration of $^{14}C$ and $^3C$ for the high radioactive samples, 8 samples, was $19000\;Bq/g{\pm}41000\;Bq/g,\;670\;Bq/g{\pm}460\;Bq/g$ and that for the low radioactive samples, 22 samples, was $4.2\;Bq/g{\pm}4.3\;Bq/g,\;6.0\;Bq/g{\pm}5.3\;Bq/g$, respectively. And the average $^{14}C/^3H$ ratio for the high radioactive samples, was higher, 28, than that of low radioactive samples, 0.70. Some linear relationship trend was found between the activity concentrations of $^{14}C\;and\;^3H$.

  • PDF

The Monitoring of Heavy Metals in Human Bloods of Middle School Students (중학생의 혈액 중 중금속 모니터링)

  • Park Hee Ra;Kim Meehye;Kwun Ki-Sung;Kim Soon Ki;Heo Su-Jeong;Kim Kwang_Jin;Yum Tae-Kyung;Choi Kwang Sik;Kim Soo Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study was conducted to estimate the contents of heavy metals including lead, cadmium, zinc, copper as well as iron status(serum iron, total iron binding capacity, feritin etc)in blood samples of middle school students(n=300). The contents of heavy metals were determined using the GF-AAS (Graphite furnace Atomic Absorption Spectrophotometer). The microwave digestion method and dilution method were compared. The dilution method showed the better recovery and detection limit than microwave digestion method. The values of toxic metals in whloe blood of boys & girls were 3.46 & 3.05 for Pb,0.063 & 0.065 for Cd respectively (ug/dL). Also the values of trace metals in serum of boys & girls were 105.9 & 92.6 for Zn, 98.3 & 99.0 for Cu respectively (ug/dL). The prevalence of iron deficiency was $7.5\%$ in 146 boys and $14.3\%$ in 156 girls. The mean values of lead in girls were higher in iron deficiency, iron deficiency anemia and anemia groups than normal group. The mean values of lead and zinc were higher in boys compared to those in girls(P<0.05), the mean values of cadmium and copper in boys were similar to those in girls. Our results of toxic metals such as Pb & Cd showed lower to CDC's(Centers for Disease Control) blood lead levels of concern for children, 10 ug/dL.

Predicting the Nutritional Value of Seafood Proteins as Measured by Newer In Vitro Model 2. C-PER and DC-PER of Marine Crustacea (수산식품 단백질 품질평가를 위한 새로운 모델 설정 2. 해산 갑각류의 C-PER 및 DC-PER)

  • RYU Hong-Soo;LEE Keun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.3
    • /
    • pp.219-226
    • /
    • 1986
  • To confirm the application of a newer in vitro assays to determining the nutritional value of marine crustaceans (mainly shrimps and crabs), which have been considered to be highly nutritive depending on their levels of the essential amino acids and digestibility, their C-PERs and DC-PERs were determined and studied the factors influencing their in vitro results. Four species of seawater shrimps and 2 species of seawater crabs were used in this experiment. The in vitro digestibilities showed $83{\sim}86\%$ for raw shrimps and the trypsin indigestibile substrate content (TIS) was ranged from 1.32 to 3.33 mg/g solid expressed quantitatively as mg of purified soybean trypsin inhibitor. The smaller size of shrimps revealed a greater in vitro digestibility and a lower contents of TIS. It was noted that the in vitro digestibility of raw blue crab meat was around $85\%$ while boiled tenner crab meat showed $86\%$ or above, and the leg meat had the greatest in vitro digestibility in the various parts of crab meats. The poor in vitro digestibilities for shrimp's and crab's meat, compared with that of the other seafoods as noted in previous reports, suggest that the drop in pH, due to the change in their freshness during harvesting and frozen storage, resulted in underestimating their digestibilities using four-enzyme digestion technique. The lysine contents in all samples were higher than that of ANRC casein but they contained a slightly lower sulfur-containing amino acids than those in ANRC casein. But the other EAA, such as valine, tyrosine and phenylalanine, were found to be a half as little as that in casein and played a key-factor in calculation of C-PER or DC-PER. It was observed that the value of C-PER and DC-PER for all samples ranged from 2.1 to 2.4, and the predicted digestibilities showed $90\%$ or above in all samples. It was a different results from the fact that the animal proteins bear a higher values and predicted digestibilities than those of C-PER values. The lack of correlation between C-PER and DC-PER values is attributable to the fact that the lower content of valine, tyrosine and phenylalanine, and drop in pH owing to the changes of freshness in marine crustacea proteins. Therefore, if a newer in vitro digestion technique-which are taken into account the pH drop before digestion, TIS content and released free amino acids and/or peptides-developed, C-PER assays can provide more advantages in assessing the protein nutritional value of marine crustacea than any other in vitro assays.

  • PDF

Physiological Activity of Sarcodon aspratus Extracts (능이버섯(Sarcodon aspratus) 추출물의 생리활성)

  • 송재환;이현숙;황진국;한정환;노정근;금동혁;박기문
    • Food Science of Animal Resources
    • /
    • v.23 no.2
    • /
    • pp.172-179
    • /
    • 2003
  • This study was carried out to find the preventive medical and therapeutic effects of Sarcodon asparatus on adult disease by employing several biological and biochemical assays. Nitrate scavenging ability(NSA) of Sarcodan asparatus extracts was displayed up to 99.9% at pH 1.2 in a dose-dependent manner. They also had 90.4% electron donating ability(EDA) at the concentration of 0.1 mg/mL. Extracts of Sarcodon asparatus were also able to function as a powerful antioxidant at all concentrations(0.01∼l.0 mg/mL). Furthermore, we observed that 1 mg/mL concentration of the extracts was more powerful than BHT, With respect to fibrolytic activity, Sarcodon asparatus showed 1,843.8 unit/g, which was higher than streptokinase(1,189 unit/g). The inhibitory effects of the extracts on angiotensin converting enzyme, measured by the normal and pretreatment methods, were 53 and 58%, respectively. We also performed cytotoxicity effect of Sarcodon asparatus extracts on a various cancer cell lines. The growth inhibitory effects of the extracts(5.0 mg/mL) on A549, HeLa, AGS, and SK-Hep-1 cells were 78.9, 55.3, 69.0, and 42.5 %, respectively. Interestingly, Sarcodon asparatusextracts induced mutation on Salmonella typhimurium TA98 and TA100 when Ames test was done.

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

A comparison study of 76Se, 77Se and 78Se isotope spikes in isotope dilution method for Se (셀레늄의 동위원소 희석분석법에서 첨가 스파이크 동위원소 76Se, 77Se 및 78Se들의 비교분석)

  • Kim, Leewon;Lee, Seoyoung;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.170-178
    • /
    • 2016
  • Accuracy and precision of ID methods for different spike isotopes of 76Se, 77Se, and 78Se were compared for the analysis of Selenium using quadrupole ICP/MS equipped with Octopole reaction cell. From the analysis of Se inorganic standard solution, all of three spikes showed less than 1 % error and 1 % RSD for both short-term (a day) and long-term (several months) periods. They showed similar results with each other and 78Se showed was a bit better than 76Se and 77Se. However, different spikes showed different results when NIST SRM 1568a and SRM 2967 were analyzed because of the several interferences on the m/z measured and calculated. Interferences due to the generation of SeH from ORC was considered as well as As and Br in matrix. The results showed similar accuracy and precisions against SRM 1568a, which has a simple background matrix, for all three spikes and the recovery rate was about 80% with steadiness. The %RSD was a bit higher than inorganic standard (1.8 %, 8.6 %, and 6.3 % for 78Se, 76Se and 77Se, respectively) but low enough to conclude that this experiment is reliable. However, mussel tissue has a complex matrix showed inaccurate results in case of 78Se isotope spike (over 100 % RSD). 76Se and 77Se showd relatively good results of around 98.6 % and 104.2 % recovery rate. The errors were less than 5 % but the precision was a bit higher value of 15 % RSD. This clearly shows that Br interferences are so large that a simple mathematical calibration is not enough for a complex-matrixed sample. In conclusion, all three spikes show similar results when matrix is simple. However, 78Se should be avoided when large amount of Br exists in matrix. Either 76Se or 77Se would provide accurate results.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF