• Title/Summary/Keyword: 표적의 크기

Search Result 210, Processing Time 0.024 seconds

Energy Detection Based Spectrum Sensing for Radar Signals in the Presence of Noise Power Uncertainty (잡음 전력 불확실성이 존재하는 환경에서 레이다 신호에 대한 에너지 검파 기반 스펙트럼 센싱)

  • Lim, Chang Heon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.5
    • /
    • pp.982-984
    • /
    • 2017
  • In time domain, a radar signal is divided into two segments: one is for a transmitted pulse and the other is for receiving possible returns from radar targets. Also the received signal is relatively weak and consists of background noise except for the reflected signals from radar targets. In this Letter, we present an energy detection based spectrum sensing for a radar signal in the presence of noise power uncertainty exploiting this characteristics.

Mono-Vision Based Satellite Relative Navigation Using Active Contour Method (능동 윤곽 기법을 적용한 단일 영상 기반 인공위성 상대항법)

  • Kim, Sang-Hyeon;Choi, Han-Lim;Shim, Hyunchul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.902-909
    • /
    • 2015
  • In this paper, monovision based relative navigation for a satellite proximity operation is studied. The chaser satellite only uses one camera sensor to observe the target satellite and conducts image tracking to obtain the target pose information. However, by using only mono-vision, it is hard to get the depth information which is related to the relative distance to the target. In order to resolve the well-known difficulty in computing the depth information with the use of a single camera, the active contour method is adopted for the image tracking process. The active contour method provides the size of target image, which can be utilized to indirectly calculate the relative distance between the chaser and the target. 3D virtual reality is used in order to model the space environment where two satellites make relative motion and produce the virtual camera images. The unscented Kalman filter is used for the chaser satellite to estimate the relative position of the target in the process of glideslope approaching. Closed-loop simulations are conducted to analyze the performance of the relative navigation with the active contour method.

Supersonic ASCMs of Soviet/Russia (소련/러시아의 초음속 대함유도탄)

  • Kim, Ki-Un;Lee, Ho-Il;Hwang, Yoojun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.5
    • /
    • pp.27-35
    • /
    • 2021
  • A technical review of Soviet/Russian supersonic anti-ship cruise missiles is presented. The supersonic anti-ship cruise missiles is one of the weapons for asymmetric power. The supersonic speed of the missiles is very useful both for attacking a time critical target and for improving target-penetration characteristics of the missile. The survivability of the missiles has also been increased by the improved concept of operation. Supersonic cruise missiles is greatly affected by the evolution of propulsion technology. Early supersonic cruise missiles adopt turbojet engines and rocket motors. The use of the integrated rocket-ramjet engine reduced the size of the supersonic missile, so today's supersonic cruise missiles are suitable to be deployed in various platforms. Nowadays, export versions of the missiles are actively being developed.

A Study on the Analysis Method of the Operations Effectiveness of the Joint Coastal Guard System Against Small Targets (소형표적에 대한 합동 해안경계시스템 작전효과 분석방법 연구)

  • Kim, Taeho;Han, Hyun Jin;Lee, Byeong-Ho;Shin, Young-Tae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • The Joint Coastal Guard System is composed of a maritime surveillance system and a anti-coastal infiltration system, and is a system in which the Navy is mainly responsible for the maritime and the Army is responsible for the coast. We analyzed the operations effectiveness of the joint coastal guard system, in which various weapon systems of the army and navy are operated in a complex way, to the extent to which successful operation is possible against small targets. The operations effectiveness analysis was conducted by defining the operations effectiveness by operation type, configuring the simulation environment using METT-T elements, establishing the assumptions of the simulation scenario, conducting the simulation and analyzing the simulation results by weather condition. The simulation tools used were NORAM and EADSIM. As a result of the operations effectiveness analysis, the joint coastal guard system currently in operation showed a significant difference in operational success depending on the size of the target and weather conditions. This research can be used as useful data for establishing an effective joint coastal guard system and conducting systematic guard operations.

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

A Feasibility Study on the Prediction of the Target in the Lung from the Skin Motion - Animal Study (피부의 움직임을 이용한 표적의 위치 추정에 관한 가능성 연구 - 동물 실험)

  • 서예린;이병용;신승애;김종훈;안승도;이상욱;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.163-168
    • /
    • 2002
  • As for planning the radiation therapy for the tumor in the lung, inferring the motion of the organ or target due to the respiration from the motion of the skin was performed as the feasibility study with the animal. The dog weighed 20 kg was chosen for the experiment. The system, which can use the fluoroscopy and the CCD camera synchronously, was designed. With a radio-opaque marker on the skin of the dog, which indicates the lower lobe of the lung, the images of the motions for the lung were recorded in the A/P (anterior-to-posterior) and lateral view. At the same time, the images of the skin motions from CCD camera were also recorded. Skin moves periodically with the amplitude of 6 mm and the target in the lung made almost the same frequencies during its motion's amplitude of 15 mm and its direction change with the respiration. Therefore analyzed results showed strong correlation between the skin motion and the organ motion on the average of 0.85. This study indicated that the prediction of a target position in the lung, which is moving organ, is possible. For the animal study, predicting the exact target motion from the skin motion was possible and it can have the feasibility to apply to the patient clinically.

  • PDF

Acquisition of Subcentimeter GSD Images Using UAV and Analysis of Visual Resolution (UAV를 이용한 Subcentimeter GSD 영상의 취득 및 시각적 해상도 분석)

  • Han, Soohee;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.563-572
    • /
    • 2017
  • The purpose of the study is to investigate the effect of flight height, flight speed, exposure time of camera shutter and autofocusing on the visual resolution of the image in order to obtain ultra-high resolution images with a GSD less than 1cm. It is also aimed to evaluate the ease of recognition of various types of aerial targets. For this purpose, we measured the visual resolution using a 7952*5304 pixel 35mm CMOS sensor and a 55mm prime lens at 20m intervals from 20m to 120m above ground. As a result, with automatic focusing, the visual resolution is measured 1.1~1.6 times as the theoretical GSD, and without automatic focusing, 1.5~3.5 times. Next, the camera was shot at 80m above ground at a constant flight speed of 5m/s, while reducing the exposure time by 1/2 from 1/60sec to 1/2000sec. Assuming that blur is allowed within 1 pixel, the visual resolution is 1.3~1.5 times larger than the theoretical GSD when the exposure time is kept within the longest exposure time, and 1.4~3.0 times larger when it is not kept. If the aerial targets are printed on A4 paper and they are shot within 80m above ground, the encoded targets can be recognized automatically by commercial software, and various types of general targets and coded ones can be manually recognized with ease.

OS CFAR Computation Time Reduction Technique to Apply Radar System in Real Time (레이다 시스템 실시간 적용을 위한 OS CFAR 연산 시간 단축 방안)

  • Kong, Young-Joo;Woo, Seon-Keol;Park, Sungho;Shin, Seung-Yong;Jang, Youn Hui;Yang, Eunjung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.791-798
    • /
    • 2018
  • The CFAR algorithm is mainly used for target detection in radar systems. In particular, OS CFAR is used in a non-uniform noise environment. However, it requires a large amount of computation, because it should sort reference cells in ascending order. This makes it difficult to apply the radar system in real time. In this paper, we describe how to reduce the computational burden of OS CFAR. We compared the power of the test cell and reference cell to determine only the presence or absence of target detection. The common reference cells overlapping in the reference cells of the three test cells are obtained. We first compare the test cell with the highest power value among the three test cells to the common reference cells. Next, we compare each test cell to general reference cells, excluding the common reference cells. The computation time is shortened by reducing the power comparison computation amounts.

Targeted Gene Delivery of the Cationic Lipid Emulsion System Containing Folate-PEG-DPPE (Folate-PEG-DPPE를 포함하는 양이온성 지질 에멀젼 시스템의 표적화 유전자 전달)

  • Kwon, Sang-Kyoo;Jeong, Kwan-Ho;Kim, Young-Jin
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.213-218
    • /
    • 2009
  • A cationic lipid emulsion containing 1,2-dioleoyl-3-trimethylammonium-propane(DOTAP), Tween80, squalene has been prepared as a gene delivery system. In order to increase the transfection efficiency of gene carrier, folate was used as the tumor-targeting ligand that was attached on PEG-DPPE. HeLa and 293 cells were used for the in vitro transfection experiment. HeLa cell is a folate-positive cell line. The mean particle sizes of polymeric lipid system and DNA/lipid complex system were 206.6 nm and 150.5 nm, respectively. The transfection efficiencies of our carriers(4:l(w:w) complex ratio)were 100 times higher than that of DOTAP only emulsion due to the targeting effect of folate.

Guidance Filter Design Based on Strapdown Seeker and MEMS Sensors (스트랩다운 탐색기 및 MEMS 센서를 이용한 유도필터 설계)

  • Yun, Joong-Sup;Ryoo, Chang-Kyung;Song, Taek-Lyul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1002-1009
    • /
    • 2009
  • Precision guidance filter design for a tactical missile with a strapdown seeker aided by low-cost strapdown sensors has been addressed in this paper. The low-cost strapdown sensors consist of an IMU with 3-axis accelerometers and gyroscopes, 3-axis magnetometers, and a barometer. Missile's position, velocity, attitude, and bias error of the barometer are considered as state variables. Since the state and measurement equations are highly nonlinear, we adopt UKF(Unscented Kalman Filter). The proposed guidance filter has a function of a navigation filter if target position error is not considered. In the case that the target position error is introduced, the proposed filter can effectively estimate the relative states of the missile to the true target. For specific engagement scenarios, we can observe that observability problems occur.